@@ -43,8 +43,12 @@ To start the current emulator harness:
|
||||
.\.venv\Scripts\python.exe h8536_emulator_probe.py --max-steps 4000000 --stop-on-tx
|
||||
.\.venv\Scripts\python.exe h8536_emulator_probe.py --max-steps 1000000 --stop-on-tx --p9-fast-path
|
||||
.\.venv\Scripts\python.exe h8536_emulator_rx_probe.py --preset connect-lcd
|
||||
.\.venv\Scripts\python.exe scripts\bench_connect_lcd_sequence.py --port COM5 --relay-port COM6 --prompt-screen
|
||||
.\.venv\Scripts\python.exe h8536_emulator_bench_replay.py captures\bench-connect-lcd-sequence-20260525-214411.txt --assert-bench-parity
|
||||
```
|
||||
|
||||
The real-device bench helper uses `pyserial`; install repo dependencies with `.\.venv\Scripts\python.exe -m pip install -r requirements.txt` if needed.
|
||||
|
||||
## What It Does
|
||||
|
||||
- Decodes the H8/500 instruction set used by the H8/536.
|
||||
@@ -85,6 +89,8 @@ To start the current emulator harness:
|
||||
- Provides an early H8/536 emulator harness with ROM/RAM/register memory mapping, reset-vector boot, SCI1 transmit capture, MOV condition-code updates, `SCB/F`, stack/call/return support, indirect `JMP/JSR @Rn` dispatch, scaffolded SCI1 RXI/ERI/TXI and interval/FRT1-OCIA/FRT2-OCIA interrupt scheduling, a P9 bit-banged bus model, a 16x4 LCD bus/DDRAM model for `H'F200`/`H'F201`, and an opt-in P9 transfer fast path.
|
||||
- Includes an emulator probe that reports hot PCs, recent P9/SCI accesses, serial report queue/gate traces, RAM lifecycle watches, final SCI1/TXI state, and captured P9 byte candidates while running the real ROM.
|
||||
- Includes an RX command probe that boots until SCI1 RXI is serviceable, injects host six-byte frames through RDR/RDRF, listens for device TX frames, and reports serial latch/table/LCD-buffer and emulated-LCD effects.
|
||||
- Includes a bench helper for replaying the emulator-derived CONNECT LCD frame sequence against the real device through COM5, with optional COM6 relay power cycling and timestamped capture logs.
|
||||
- Includes a bench-log replay harness that feeds recorded host TX frames back into the ROM emulator and asserts parity against the real device's observed response/LCD state.
|
||||
|
||||
Current serial observations:
|
||||
|
||||
@@ -96,6 +102,7 @@ Current serial observations:
|
||||
- Runtime-confirmed heartbeat path: `loc_4067` writes `H'0000` into the queue via a zero-extended word move, `loc_BAF2/loc_BB08` dequeue it, `loc_BB1C/loc_BB20/loc_BB2B` stage the TX bytes, and `loc_BA26` emits `00 00 00 00 80 DA`.
|
||||
- Emulator LCD finding: the ROM writes the boot/no-active-session message to the LCD bus as ` CONNECT:NOT ACT` on line 0 by the time SCI1 RX is serviceable. Valid and invalid six-byte host frames leave that display active while normal serial replies/heartbeats continue.
|
||||
- RX probe finding: the `--preset connect-lcd` sequence reaches the command-`0x04` handler; `04 00 00 80 00 DE` writes table index zero, fills the LCD line buffer with `CONNECT: OK`, and emits `02 00 02 00 00 5A` in the current emulator model.
|
||||
- Bench follow-up: replaying the emulator CONNECT sequence on the real device did not switch the LCD to OK. The real device answered the `04 00 00 80 00 DE` step with `07 80 C0 60 20 5D` in the captured run and remained at `CONNECT NOT ACT`, which points to a missing gate/session precondition in the emulator.
|
||||
- Observed capture labels such as `cam_power_button_candidate` and `call_button_candidate` are deliberately treated as capture overlays, not protocol facts hard-coded in ROM.
|
||||
|
||||
The generated listing is written to:
|
||||
@@ -208,6 +215,8 @@ python h8536_emulator_rx_probe.py --help
|
||||
- `--target-frame "00 00 00 00 80 DA"`: compare staged/emitted TX bytes against an expected six-byte frame.
|
||||
- `h8536_emulator_rx_probe.py "04 00 00 80 00"`: append the checksum, inject the host frame through SCI1 RX, and summarize responses.
|
||||
- `h8536_emulator_rx_probe.py --preset connect-lcd`: replay the current CONNECT LCD activation candidates.
|
||||
- `scripts\bench_connect_lcd_sequence.py --port COM5 --relay-port COM6 --prompt-screen`: power-cycle the bench device, wait for heartbeat readiness, send `04 00 00 40 00 1E`, `04 00 00 80 00 DE`, `04 00 00 C0 00 9E`, log RX/TX, and prompt for observed LCD text.
|
||||
- `h8536_emulator_bench_replay.py captures\bench-connect-lcd-sequence-20260525-214411.txt --assert-bench-parity`: replay a real bench log into the emulator and intentionally fail while the emulator still emits `02 00 02 00 00 5A` instead of the bench-observed `07 80 C0 60 20 5D`.
|
||||
- Current status: boots from `H'1000`, initializes SCI1, models the first P9 bit-banged handshakes, captures P9 byte candidates, can optionally fast-path known P9 routines, schedules FRT1/FRT2 OCIA, captures the ROM-driven LCD line ` CONNECT:NOT ACT`, and emits the observed heartbeat frame `00 00 00 00 80 DA`.
|
||||
|
||||
## Code Layout
|
||||
@@ -250,4 +259,5 @@ python h8536_emulator_rx_probe.py --help
|
||||
- `h8536_serial_pseudocode.py`: focused serial pseudocode CLI wrapper.
|
||||
- `h8536_protocol_trace.py`, `h8536_protocol_capture.py`: protocol analysis CLI wrappers.
|
||||
- `h8536_serial_gate.py`, `h8536_report_source_trace.py`, `h8536_table_xrefs.py`, `h8536_consistency.py`: sidecar analysis CLI wrappers.
|
||||
- `h8536_emulator.py`, `h8536_emulator_probe.py`, `h8536_emulator_rx_probe.py`: emulator CLI wrappers.
|
||||
- `h8536_emulator.py`, `h8536_emulator_probe.py`, `h8536_emulator_rx_probe.py`, `h8536_emulator_bench_replay.py`: emulator CLI wrappers.
|
||||
- `scripts/bench_connect_lcd_sequence.py`: real-device COM5/COM6 bench runner for the CONNECT LCD sequence.
|
||||
|
||||
Reference in New Issue