316 KiB
Discovery Notes
This file records hands-on observations separately from manual-derived facts. Treat these as bench notes: useful and current, but still worth rechecking with photos, continuity tests, and instrument captures.
2026-05-13 - RCP-TX7 10-Pin Power and Cable
Observed on the RCP-TX7 10-pin remote connector/cable during restoration work:
- Pin 9 confirmed as ground / DC return.
- Pin 10 confirmed as power input.
- Cable color for pin 9 / ground: brown.
- Cable color for pin 10 / +12 V power: brown-white.
- Cable colors for pins 1-8 have been continuity-mapped; see the working cable map below.
- Yellow and yellow-white conductors are present in the cable but did not map to connector pins during continuity testing.
- Multimeter reading from pin 9 ground to pin 4 serial data: about -9 V.
- Multimeter reading from pin 9 ground to pin 7 serial data: about +0.037 V.
- Pins 4 and 7 were the only serial-related combinations that produced a meaningful multimeter result during this check.
- With power present on pins 9 and 10, the panel shows a green
PANEL ACTIVElight. - The inside of the 10-pin cable contains 12 wires total.
- Three of those wire groups are twisted pairs.
Immediate implications:
- The bench result agrees with the RCP-TX7 and CCU-TX7 manual pinout for pins 9 and 10.
- The 12-conductor cable construction suggests not every conductor maps one-to-one to the 10 connector pins; shielding/drain, duplicated grounds, or paired signal returns may be present.
- The three twisted pairs are likely important candidates for serial data, composite video, and/or power/ground pairing, but this should be confirmed by continuity testing rather than color or twist assumptions.
- Pin 4 measuring around -9 V relative to pin 9 strongly suggests true RS-232 level idle on at least the RCP-to-CCU/camera data line.
- Pin 7 near 0 V may be inactive/floating until a CCU or camera drives the return data line.
Working Cable Map
This table combines the manual-derived pin purpose with hands-on color mapping.
Rows marked confirmed have been checked on the current cable/panel under test.
| Pin | Purpose | Cable color | Status | Notes |
|---|---|---|---|---|
| 1 | Spare / unused | red | confirmed | No function shown in service manual. |
| 2 | VBS / composite video X | black | confirmed | 1.0 Vp-p composite video input to RCP. |
| 3 | VBS / composite video ground | green | confirmed | Video reference/ground. |
| 4 | Serial data, RCP to CCU/camera | orange | confirmed | RS-232C-based data direction. |
| 5 | Serial/data ground | blue | confirmed | One of two serial/data grounds. |
| 6 | Serial/data ground | grey | confirmed | One of two serial/data grounds. |
| 7 | Serial data, CCU/camera to RCP | purple | confirmed | RS-232C-based data direction. |
| 8 | Spare / unused | purple-white | confirmed | No function shown in service manual. |
| 9 | DC return / ground | brown | confirmed | Confirmed as ground on current cable. |
| 10 | +12 V remote power input | brown-white | confirmed | Confirmed as power input on current cable. |
Unmapped Cable Conductors
The cable contains two additional conductors that did not show continuity to the 10 connector pins during the current test:
| Conductor color | Current status | Notes |
|---|---|---|
| yellow | unmapped | May be shield/drain-related, spare, broken, or connected only at one end. |
| yellow-white | unmapped | May be shield/drain-related, spare, broken, or connected only at one end. |
Recheck these against connector shells, shield braid/drain, cable strain relief hardware, and both ends of the cable if accessible.
Suggested next observations to capture:
- Connector orientation photo showing pin numbering reference.
- Wire color list, including which colors form each twisted pair.
- Confirm whether yellow and yellow-white connect to shield, shell, or one end only.
- Resistance between pins 5, 6, and 9 with the cable disconnected.
- Scope idle voltage and activity on pins 4 and 7 relative to pins 5/6 and pin 9 while pressing panel controls and, later, while connected to a CCU or camera.
Serial Capture Setup
Initial USB serial adapter wiring for passive listening:
| Adapter terminal | RCP-TX7 cable pin | Cable color | Purpose |
|---|---|---|---|
GND |
9 | brown | Shared reference / DC return |
RXD |
4 | orange | Listen to RCP-to-CCU/camera serial data |
Do not connect adapter TXD during the first capture pass. Pin 4 measured about
-9 V relative to pin 9, so use the adapter's RS-232 side, not TTL UART mode.
Capture helper:
python -m pip install pyserial
python scripts/serial_sniff.py --list
python scripts/serial_sniff.py --port COM3 --baud 38400 --ascii
python scripts/serial_sniff.py --port COM3 --baud 38400 --frame-size 6 --log captures/rcp-pin4.txt
Replace COM3 with the adapter port shown by --list or Windows Device
Manager. While the script is running, press simple RCP controls and watch for
new hex bytes.
2026-05-13 Initial Pin 4 Capture
With the adapter in RS-232 mode, adapter RXD connected to RCP pin 4, and
adapter GND connected to pin 9, the stream produced repeating 6-byte patterns:
00 00 00 00 80 DA
00 00 07 80 00 DD
Observed behavior:
- Frames repeat roughly every 200 ms during the sample.
- The stream sometimes appeared split as
00followed by five bytes, which is likely a read-timeout/chunking artifact rather than a protocol feature. - Button presses did not obviously correlate with a visible byte change in the first capture.
Current interpretation:
- This looks like a regular RCP-origin heartbeat/status transmission on pin 4, not random noise.
- Because only pin 4 is connected, this may be the panel repeatedly trying to announce itself or poll a missing CCU/camera.
- Pin 7 measured near 0 V and is probably quiet until a CCU/camera drives the return channel.
Next capture passes:
- Use
--frame-size 6to avoid misleading1 + 5packet splits. - Capture a quiet baseline for 30 seconds.
- Capture separate files while pressing one control repeatedly, naming the action in the filename.
- Later, capture pin 7 when connected to a real CCU/camera or a controlled test transmitter.
2026-05-13 Baseline vs CAM POWER Capture
Capture files:
captures/rcp-pin4-baseline.txtcaptures/rcp-pin4-cam-power.txtcaptures/rcp-pin4-call.txt
Frame counts from the available logs:
| Capture | Frame | Count | Current label |
|---|---|---|---|
| baseline | 00 00 00 00 80 DA |
67 | idle heartbeat |
| CAM POWER | 00 00 00 00 80 DA |
23 | idle heartbeat |
| CAM POWER | 00 00 07 80 00 DD |
4 | CAM POWER candidate |
| CALL | 00 00 00 00 80 DA |
17 | idle heartbeat |
| CALL | 00 00 15 80 00 CF |
4 | CALL candidate, state/high bit set |
| CALL | 00 00 15 00 00 4F |
4 | CALL candidate, state/high bit clear |
Current interpretation:
- The baseline capture contains only
00 00 00 00 80 DA. - Pressing
CAM POWERintroduces00 00 07 80 00 DD. - Pressing
CALLintroduces00 00 15 80 00 CFand00 00 15 00 00 4F. - Other tested buttons did not obviously produce unique frames while the panel was not connected to a CCU/camera.
CAM POWERandCALLmay be among the few controls the panel transmits even without a completed host/CCU session.- The CALL frames differ by byte 4 (
80vs00) and final byte (CFvs4F), suggesting a state bit plus checksum or complement-style trailing byte. - Current checksum hypothesis: byte 6 is XOR checksum with seed
0x5Aover the first five bytes. Examples:5A xor 00 xor 00 xor 00 xor 00 xor 80 = DA5A xor 00 xor 00 xor 07 xor 80 xor 00 = DD5A xor 00 xor 00 xor 15 xor 80 xor 00 = CF5A xor 00 xor 00 xor 15 xor 00 xor 00 = 4F
Helper for future captures:
python scripts/analyze_capture.py captures/rcp-pin4-baseline.txt captures/rcp-pin4-cam-power.txt captures/rcp-pin4-call.txt
Host Response Experiments
The RCP currently appears to be in an offline heartbeat state. With no CCU/camera
response present, only CAM POWER and CALL have been observed to send unique
frames beyond the heartbeat. The next protocol step is to learn what the RCP
expects on pin 7 (CCU/camera -> RCP).
Important wiring for host-response tests:
| Adapter terminal | RCP-TX7 cable pin | Cable color | Purpose |
|---|---|---|---|
GND |
9 | brown | Shared reference / DC return |
TXD |
7 | purple | Candidate host-to-RCP transmit line |
Suggested safety precautions:
- Use the adapter's RS-232 side, not TTL UART.
- Keep adapter
RXDon pin 4 if possible so the RCP output is still logged. - Add a series resistor, for example 1 k to 4.7 k, between adapter
TXDand pin 7 for early experiments. - Send one candidate frame at a time or repeat at a slow cadence. Avoid brute forcing unknown byte ranges.
- Watch for changes in heartbeat, LCD state, panel lock state, or new frames on pin 4.
Frame sender:
python scripts/serial_send_frame.py --port COM3 --dry-run
python scripts/serial_send_frame.py --port COM3 --frame "00 00 00 00 80 DA" --repeat 5 --interval 0.2
On Windows, a COM port is usually exclusive, so the sniffer and sender cannot open the same adapter at the same time. Use the combined probe script when RXD is connected to pin 4 and TXD is connected to pin 7:
python scripts/serial_probe_response.py --port COM3 --tx-frame "00 00 00 00 80 DA" --repeat 5 --interval 0.2 --log captures/rcp-response-test.txt
This listens first, sends the candidate response from the same serial session, then keeps listening for changes on pin 4.
Candidate first response:
00 00 00 00 80 DA- mirror the observed heartbeat as a possible no-op/ack.
If mirroring the heartbeat changes nothing, the next low-risk approach is to capture a real CCU/camera response rather than guessing. If no host is available, try only checksum-valid, documented-frame-shape candidates and record every attempt in a separate capture log.
2026-05-13 Heartbeat Mirror Response Result
Experiment:
- Adapter
TXDconnected to RCP pin 7. - Sent
00 00 00 00 80 DAon the host-to-RCP line as a mirrored heartbeat / possible no-op acknowledgement. - Capture file:
captures/rcp-response-heartbeat-mirror.txt.
Observed result:
- The RCP screen changed to
CONNECT: NOT ACT. - During this capture, pin 4 still transmitted only
00 00 00 00 80 DA. - Frame count: 59 received heartbeat frames, 10 transmitted mirrored heartbeat frames.
- Pin 4 heartbeat timing became more frequent during the response window, then returned to the slower baseline cadence afterward.
Current interpretation:
- The RCP is detecting return-channel traffic on pin 7.
- Mirroring the heartbeat is enough to move the panel out of the simple offline state, but it does not complete active host/CCU negotiation.
NOT ACTlikely means connected/not active, connected/not activated, or a similar state where the link is electrically/protocol-visible but no valid control session has been established.- The RCP did not emit a new command/status frame on pin 4 in response to the mirrored heartbeat, so the next handshake step is probably not simply an echo of its heartbeat.
Additional checksum-valid response tests:
| Capture | TX frame | RX result on pin 4 | Screen result |
|---|---|---|---|
captures/rcp-response-zero-state.txt |
00 00 00 00 00 5A |
heartbeat only | CONNECT: NOT ACT |
captures/rcp-response-state-byte4.txt |
00 00 00 80 00 DA |
heartbeat only | CONNECT: NOT ACT |
captures/rcp-response-invalid-checksum.txt |
00 00 00 00 80 00 |
heartbeat only | CONNECT: NOT ACT |
| TXD connected, no transmitted bytes | RS-232 idle only | heartbeat only | no CONNECT: NOT ACT |
| Single-byte test | 00 |
heartbeat only | no CONNECT: NOT ACT |
| Single-byte test | FF |
heartbeat only | no CONNECT: NOT ACT |
| Short-frame test | 00 00 00 |
heartbeat only | no CONNECT: NOT ACT |
| Frame-length test | 00 00 00 00 |
heartbeat only | no CONNECT: NOT ACT |
| Frame-length test | 00 00 00 00 80 |
heartbeat only | no CONNECT: NOT ACT |
| Frame-length test | 00 00 00 00 80 DA 00 |
heartbeat only | CONNECT: NOT ACT |
Updated interpretation:
CONNECT: NOT ACTis probably a link-present state, not proof of a correct CCU handshake.- The RCP reacts to several checksum-valid 6-byte frames on pin 7, but continues sending only the pin 4 heartbeat.
- An intentionally invalid checksum frame also produced
CONNECT: NOT ACT, so that display state does not prove checksum acceptance. - The response needed to enter an active control session likely needs a specific status/identity/activation frame, not just a valid no-op frame shape.
- TXD connected at idle without transmitted bytes did not produce
CONNECT: NOT ACT, so the display state appears to require received byte activity on pin 7, not merely a driven RS-232 idle level. - Single-byte and three-byte transmissions did not produce
CONNECT: NOT ACT, so the RCP is likely recognizing a minimum frame length or parser shape rather than arbitrary serial bytes. - Four-byte and five-byte transmissions did not produce
CONNECT: NOT ACT, but a seven-byte transmission beginning with the known six-byte heartbeat did. This suggests the first six bytes are enough to trigger the parser/link state, and the seventh byte may be ignored, buffered for a later frame, or treated as extra data after the recognized packet. - None of the tested host frames have caused the RCP to emit anything on pin 4 except the heartbeat.
Command-field response tests, using frame shape 00 00 CMD 00 80 CHECKSUM:
| Capture | TX frame | Checksum | Screen result | Notes |
|---|---|---|---|---|
captures/rcp-response-cmd01.txt |
00 00 01 00 80 DB |
valid | CONNECT: NOT ACT |
6-byte command-shaped frame accepted enough to change display. |
captures/rcp-response-cmd02.txt |
00 00 02 00 80 DB |
invalid | CONNECT: NOT ACT |
Bad checksum still changed display. |
captures/rcp-response-cmd02.txt |
00 00 02 00 80 D8 |
valid | CONNECT: NOT ACT |
Valid checksum also changed display. |
captures/rcp-response-cmd03.txt |
00 00 03 00 80 D9 |
valid | CONNECT: NOT ACT |
6-byte command-shaped frame accepted enough to change display. |
captures/rcp-response-cmd04.txt |
00 00 7F 00 80 A5 |
valid | no screen change | First observed checksum-valid 6-byte frame that does not trigger CONNECT: NOT ACT. |
captures/rcp-response-cmd05.txt |
00 00 80 00 80 5A |
valid | CONNECT: NOT ACT |
6-byte command-shaped frame accepted enough to change display. |
Implications from command-field tests:
- Screen change is not simply based on frame length or checksum validity.
- The command/status byte matters:
0x7Fappears ignored or treated as non-link-establishing, despite a valid checksum. - Tested commands
0x00,0x01,0x02,0x03, and0x80can triggerCONNECT: NOT ACT;0x7Fdid not. - The RCP operating manual notes that
CAM POWER,MASTER/SLAVE, and some monitor functions are available only when connected to a CCU, so active state may depend on CCU identity/status bits.
Next low-risk response experiments:
- Repeat the same test with logging enabled so the pin 4 output before, during,
and after
CONNECT: NOT ACTis captured. - Try sending the mirrored heartbeat continuously at a cadence close to the RCP heartbeat, for example every 0.6 seconds, and watch whether the display state changes.
- Probe semantic fields within the six-byte frame shape, changing one byte at a time and logging both screen state and pin 4 output. Prioritize small command values and avoid broad brute-force sweeps.
- Prefer capturing a real CCU/camera pin 7 response before broad guessing.
Command Sweep Helper
A cautious command-byte sweep helper is available at
scripts/serial_sweep_commands.py. It sends only checksum-valid six-byte frames
using the current frame/checksum hypothesis and marks any RCP output that is not
the known heartbeat.
Recommended first sweep:
python scripts/serial_sweep_commands.py --port COM5 --start 0x00 --end 0x20 --after-each 1.0 --log captures/rcp-sweep-cmd-00-20.txt
Optional dry run:
python scripts/serial_sweep_commands.py --port COM5 --start 0x00 --end 0x20 --dry-run
Use small ranges and keep watching the RCP screen while the sweep runs. The log captures TX/RX bytes, but it cannot record screen messages unless they are noted manually afterward.
The 0x00-0x20 sweep produced CONNECT: NOT ACT roughly halfway through the
run, but the exact command was not recorded in the log. Rerun a narrower range
with manual screen prompts:
python scripts/serial_sweep_commands.py --port COM5 --start 0x0C --end 0x14 --after-each 1.2 --prompt-screen --log captures/rcp-sweep-cmd-0c-14-screen.txt
At each prompt, press Enter for no screen change, type CONNECT: NOT ACT when
that appears, or type q to stop.
Prompted sweep result:
- Capture:
captures/rcp-sweep-cmd-0c-14-screen.txt. - The RCP was reset after each screen trigger to clear its state, so recorded triggers should be treated as independent fresh observations.
- First recorded screen marker: after command
0x0C, frame00 00 0C 00 80 D6, screenCONNECT: NOT ACT. - Later manual screen markers were recorded after
0x0D,0x10,0x11,0x12,0x13, and0x14. - No manual screen markers were recorded after
0x0Eor0x0F. - Pin 4 output remained the heartbeat
00 00 00 00 80 DAthroughout.
Interpretation:
- Commands
0x0C,0x0D,0x10,0x11,0x12,0x13, and0x14have independent evidence of triggeringCONNECT: NOT ACTin this sweep. - Commands
0x0Eand0x0Fdid not have a screen marker recorded in this sweep and are current non-trigger candidates. - Because pin 4 stayed heartbeat-only, this state change is visible on the LCD but does not yet produce a new RCP-to-host serial response.
Second prompted sweep result:
- Capture:
captures/rcp-sweep-cmd-15-30-screen.txt. - The log includes one partial/restarted pass at the beginning, then a fuller
prompted sweep through
0x30. - Pin 4 output remained the heartbeat
00 00 00 00 80 DAthroughout.
Commands with recorded CONNECT: NOT ACT screen markers:
| Command | TX frame |
|---|---|
0x15 |
00 00 15 00 80 CF |
0x16 |
00 00 16 00 80 CC |
0x17 |
00 00 17 00 80 CD |
0x18 |
00 00 18 00 80 C2 |
0x19 |
00 00 19 00 80 C3 |
0x1A |
00 00 1A 00 80 C0 |
0x1B |
00 00 1B 00 80 C1 |
0x1C |
00 00 1C 00 80 C6 |
0x1D |
00 00 1D 00 80 C7 |
0x28 |
00 00 28 00 80 F2 |
0x29 |
00 00 29 00 80 F3 |
0x2C |
00 00 2C 00 80 F6 |
0x2D |
00 00 2D 00 80 F7 |
0x30 |
00 00 30 00 80 EA |
Commands with no recorded screen marker in this sweep:
0x1E 0x1F 0x20 0x21 0x22 0x23 0x24 0x25
0x26 0x27 0x2A 0x2B 0x2E 0x2F
Emerging pattern:
- Some command byte ranges trigger
CONNECT: NOT ACTwhile nearby checksum-valid commands do not. - Triggering still does not make the RCP transmit anything except the heartbeat.
CONNECT: NOT ACTappears to be a parser-recognized but not session-active state. It may indicate the RCP recognizes the command class as CCU-like, but the remaining status/identity/activation fields are wrong or incomplete.
Targeted Field Matrix Probe
After the 0x15-0x30 sweep, the best next experiment is not a broader command
sweep. The command byte is clearly relevant, but active-session behavior may
depend on the state/value fields or the prefix bytes. Use
scripts/serial_probe_matrix.py to hold one promising command constant and vary
only a small set of fields.
Start with command 0x15 because it is already associated with the RCP's own
CALL output frames:
python scripts/serial_probe_matrix.py --port COM5 --commands 0x15 --states "0x00 0x80" --values "0x00 0x80" --after-each 1.2 --prompt-screen --log captures/rcp-matrix-cmd15-state-value.txt
Dry-run frames:
00 00 15 00 00 4F
00 00 15 00 80 CF
00 00 15 80 00 CF
00 00 15 80 80 4F
Why this is useful:
00 00 15 00 00 4Fand00 00 15 80 00 CFmatch the RCP's observedCALLframes.00 00 15 00 80 CFmatches the command-sweep shape that triggeredCONNECT: NOT ACT.00 00 15 80 80 4Fchecks whether both high/state bits together change the parser state.
If all four still produce only CONNECT: NOT ACT or no change, the next matrix
should keep cmd=0x15, state=0x00, value=0x80, and vary only prefix bytes:
python scripts/serial_probe_matrix.py --port COM5 --prefix2s "0x00-0x0F" --commands 0x15 --states 0x00 --values 0x80 --after-each 1.2 --prompt-screen --log captures/rcp-matrix-cmd15-prefix2-00-0f.txt
Treat any result other than heartbeat-only pin 4 output as high-priority. In
particular, look for a new RCP frame, a different LCD message, or any transition
from CONNECT: NOT ACT to an active/connected state.
2026-05-13 Command 0x15 State/Value Matrix Result
Capture:
captures/rcp-matrix-cmd15-state-value.txt
Frames tested:
| Command | State | Value | TX frame | Screen result |
|---|---|---|---|---|
0x15 |
0x00 |
0x00 |
00 00 15 00 00 4F |
CONNECT NOT ACT |
0x15 |
0x00 |
0x80 |
00 00 15 00 80 CF |
CONNECT NOT ACT |
0x15 |
0x80 |
0x00 |
00 00 15 80 00 CF |
CONNECT NOT ACT |
0x15 |
0x80 |
0x80 |
00 00 15 80 80 4F |
CONNECT NOT ACT |
Analyzer result:
- Pin 4 RX stayed at heartbeat only:
00 00 00 00 80 DA. - No non-heartbeat RCP-to-host frames were observed.
- The RCP was sensitive to all four command
0x15variants, including both frames that match the panel's ownCALLoutput, but none advanced the panel beyondCONNECT NOT ACT.
Interpretation:
- For command
0x15, the tested state/value high bits are not enough to produce an active session. - The missing host response is likely in another field, a required repeated cadence, a multi-frame exchange, or a CCU/camera identity/status frame.
- Since command
0x15is parser-visible across all tested state/value variants, it is a good anchor for prefix-byte testing.
Recommended next matrix:
python scripts/serial_probe_matrix.py --port COM5 --prefix2s "0x00-0x0F" --commands 0x15 --states 0x00 --values 0x80 --after-each 1.2 --prompt-screen --log captures/rcp-matrix-cmd15-prefix2-00-0f.txt
If all prefix2 values behave the same, repeat with prefix1s "0x00-0x0F" and
prefix2s 0x00. Prefix bytes may encode device address, CCU identity, panel
number, or bus direction.
2026-05-13 Command 0x15 Prefix2 Matrix Result
Capture:
captures/rcp-matrix-cmd15-prefix2-00-0f.txt
Test shape:
p1=0x00p2=0x00-0x0Fcmd=0x15state=0x00value=0x80
Analyzer result:
- Pin 4 RX stayed at heartbeat only:
00 00 00 00 80 DA. - No non-heartbeat RCP-to-host frames were observed.
- The log contains 263 heartbeat RX frames and 16 transmitted prefix2 variants.
Screen observations:
CONNECT NOT ACTwas recorded after prefix2 values0x00,0x01,0x02,0x03,0x04,0x05,0x06,0x08,0x09,0x0A,0x0B,0x0C,0x0D, and0x0E.- No screen marker was recorded after prefix2
0x07or0x0F. - One marker was typed as
CONNECT NTO ACT; treat this as the same observation unless later testing proves otherwise.
Interpretation:
- Prefix2 did not produce an active session in the tested low-nibble range.
- The missing response is still not visible on pin 4.
- The missing markers at
0x07and0x0Fmay be real parser behavior, because both have low three bits set, but this needs a focused confirmation run before treating it as a rule.
Recommended confirmation:
python scripts/serial_probe_matrix.py --port COM5 --prefix2s "0x06 0x07 0x08 0x0E 0x0F" --commands 0x15 --states 0x00 --values 0x80 --after-each 1.2 --prompt-screen --log captures/rcp-matrix-cmd15-prefix2-confirm.txt
Reset the RCP after any screen-triggering result. This keeps the comparison between trigger and non-trigger prefix2 values clean.
2026-05-13 Prefix2 Confirmation Result
Capture:
captures/rcp-matrix-cmd15-prefix2-confirm.txt
Test shape:
p1=0x00p2=0x06,0x07,0x08,0x0E,0x0Fcmd=0x15state=0x00value=0x80
Screen observations:
| Prefix2 | TX frame | Screen marker |
|---|---|---|
0x06 |
00 06 15 00 80 C9 |
CONNECT NOT ACT |
0x07 |
00 07 15 00 80 C8 |
none recorded |
0x08 |
00 08 15 00 80 C7 |
CONNECT NOT ACT |
0x0E |
00 0E 15 00 80 C1 |
CONNECT NOT ACT |
0x0F |
00 0F 15 00 80 C0 |
none recorded |
Analyzer result:
- 65 heartbeat RX frames:
00 00 00 00 80 DA. - 14 apparent non-heartbeat RX frames after
p2=0x0F:00 00 00 80 DA 00. - No other RCP-to-host frame shape was observed.
Interpretation:
p2=0x07andp2=0x0Fagain failed to produce a recorded screen marker, while neighboring values did.- The apparent
00 00 00 80 DA 00response afterp2=0x0Fis probably a one-byte framing slip of the normal heartbeat stream, because it is exactly the heartbeat sequence viewed from byte offset 1:00 00 00 00 80 DA 00 00 .... - Because the shifted heartbeat also satisfies the current XOR checksum hypothesis, checksum validity alone is not enough to prove frame alignment.
Recommended raw confirmation for p2=0x0F:
python scripts/serial_probe_response.py --port COM5 --tx-frame "00 0F 15 00 80 C0" --repeat 1 --delay 1.5 --after 5 --frame-size 0 --log captures/rcp-prefix2-0f-raw.txt
Then repeat for p2=0x07:
python scripts/serial_probe_response.py --port COM5 --tx-frame "00 07 15 00 80 C8" --repeat 1 --delay 1.5 --after 5 --frame-size 0 --log captures/rcp-prefix2-07-raw.txt
Raw capture avoids imposing 6-byte alignment on the received stream, so it should show whether the apparent non-heartbeat is a real frame or just a shifted view of the heartbeat.
Series Resistor Note
Current host-to-RCP tests use a series resistor between adapter TXD and RCP
pin 7 as a protection measure. A 4.7 kOhm series resistor should normally still
work with a high-impedance RS-232 receiver input, so it is unlikely to explain a
selective pattern where nearby checksum-valid frames behave differently.
Possible resistor-related failure modes:
- If the RCP input is much lower impedance than expected, 4.7 kOhm could reduce the voltage swing at pin 7.
- If the input is clamped internally, the resistor may limit current enough to make the received waveform marginal.
- Marginal signaling would more likely produce random missed/garbled frames than a repeatable distinction between specific prefix values.
Low-risk check:
- Measure pin 7 relative to pin 9 on the RCP side of the resistor while the adapter is idle; it should show a strong RS-232 idle level, not near 0 V.
- If testing without the resistor, first try a smaller protection resistor such as 1 kOhm rather than going straight to a direct connection.
- Compare one known-trigger frame, such as
00 06 15 00 80 C9, and one suspected non-trigger frame, such as00 07 15 00 80 C8, using the same reset procedure.
Direct Response Sweep Without Screen Logging
For response hunting, use scripts/serial_direct_response_sweep.py rather than
the older fixed-frame sweep. It sends checksum-valid 6-byte host frames, but
reads pin 4 as raw bytes and checks whether the received data can be explained
as the repeated heartbeat:
00 00 00 00 80 DA
This avoids treating shifted heartbeat bytes such as 00 00 00 80 DA 00 as a
new response frame.
Recommended first direct sweep:
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0x00-0xFF" --states 0x00 --values 0x80 --after-each 0.6 --stop-on-anomaly --log captures/rcp-direct-cmd-00-ff.txt
For a long sweep where every anomaly should be logged but the panel needs a
fresh power cycle before continuing, use --pause-on-anomaly instead of
--stop-on-anomaly. After the prompt, power-cycle the RCP, wait for the normal
heartbeat, then press Enter.
What to watch for:
- If the script reports
Anomalies: 0, the panel never sent raw bytes that differed from the heartbeat stream during this sweep. - If it stops on an anomaly, preserve the log and rerun only the reported frame with raw capture before assuming it is a real response.
- Keep the same resistor/wiring setup for this run so the result remains comparable to the earlier observations.
If the command-only direct sweep finds nothing, the next direct grid should be split into two chunks to stay within the default safety limit:
python scripts/serial_direct_response_sweep.py --port COM5 --prefix2s "0x00-0x0F" --commands "0x00-0x1F" --states 0x00 --values 0x80 --after-each 0.4 --stop-on-anomaly --log captures/rcp-direct-p2-00-0f-cmd-00-1f.txt
python scripts/serial_direct_response_sweep.py --port COM5 --prefix2s "0x00-0x0F" --commands "0x20-0x3F" --states 0x00 --values 0x80 --after-each 0.4 --stop-on-anomaly --log captures/rcp-direct-p2-00-0f-cmd-20-3f.txt
2026-05-13 Direct Command Sweep Response Hit
Capture:
captures/rcp-direct-cmd-00-ff.txt
Sweep shape:
p1=0x00p2=0x00cmd=0x00-0xFFstate=0x00value=0x80- Stop on first raw RX anomaly.
Important result:
- The sweep stopped immediately after transmitting command
0xB5:00 00 B5 00 80 6F. - The previous transmitted command was
0xB4:00 00 B4 00 80 6E, about 0.6 seconds earlier. - The RCP produced repeated non-heartbeat frames:
07 80 6D 20 D8 48. - Final raw capture showed the same frame repeated, then the panel returned to
the normal heartbeat
00 00 00 00 80 DA.
Observed response:
07 80 6D 20 D8 48
07 80 6D 20 D8 48
07 80 6D 20 D8 48
...
00 00 00 00 80 DA
Checksum check:
5A xor 07 xor 80 xor 6D xor 20 xor D8 = 48.- This means
07 80 6D 20 D8 48is a real checksum-valid 6-byte frame under the current checksum hypothesis, not a shifted heartbeat artifact.
Interpretation:
- This is the first confirmed non-heartbeat RCP-to-host serial response on pin 4 during host-frame probing.
cmd=0xB5is the most likely trigger, butcmd=0xB4should be retested because it was sent one read window earlier and delayed responses are possible.- The response frame shape suggests the RCP may be reporting a status or
identity-like frame with
p1=0x07,p2=0x80,cmd=0x6D,state=0x20,value=0xD8.
Recommended confirmation tests:
python scripts/serial_probe_response.py --port COM5 --tx-frame "00 00 B4 00 80 6E" --repeat 1 --delay 1.5 --after 5 --frame-size 0 --log captures/rcp-confirm-cmd-b4-raw.txt
python scripts/serial_probe_response.py --port COM5 --tx-frame "00 00 B5 00 80 6F" --repeat 1 --delay 1.5 --after 5 --frame-size 0 --log captures/rcp-confirm-cmd-b5-raw.txt
python scripts/serial_probe_response.py --port COM5 --tx-frame "00 00 B6 00 80 6C" --repeat 1 --delay 1.5 --after 5 --frame-size 0 --log captures/rcp-confirm-cmd-b6-raw.txt
If cmd=0xB5 reliably triggers the 07 80 6D 20 D8 48 response, test whether
the response depends on the state/value fields:
python scripts/serial_probe_matrix.py --port COM5 --commands 0xB5 --states "0x00 0x80" --values "0x00 0x80" --after-each 1.2 --prompt-screen --log captures/rcp-matrix-cmd-b5-state-value.txt
2026-05-13 B4/B5/B6 Single-Frame Confirmation
Captures:
captures/rcp-confirm-cmd-b4-raw.txtcaptures/rcp-confirm-cmd-b5-raw.txtcaptures/rcp-confirm-cmd-b6-raw.txt
Single frames tested:
| Command | TX frame | Pin 4 result |
|---|---|---|
0xB4 |
00 00 B4 00 80 6E |
heartbeat only |
0xB5 |
00 00 B5 00 80 6F |
heartbeat only |
0xB6 |
00 00 B6 00 80 6C |
heartbeat only |
Interpretation:
- The earlier
07 80 6D 20 D8 48response did not reproduce from isolated single-frameB4,B5, orB6tests. - The response may require prior sweep history, a command sequence, repeated cadence, or a temporary parser/session state produced by many earlier frames.
- The
B5frame is still the best suspect because the direct sweep reported the anomaly in the read window immediately after transmittingB5, but it is not sufficient by itself in a fresh single-frame test.
Recommended focused replay:
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0xB0-0xB8" --states 0x00 --values 0x80 --after-each 0.6 --stop-on-anomaly --log captures/rcp-direct-cmd-b0-b8-replay.txt
If that does not reproduce the response, try the same range with a shorter cadence to better mimic the long sweep:
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0xB0-0xB8" --states 0x00 --values 0x80 --after-each 0.25 --stop-on-anomaly --log captures/rcp-direct-cmd-b0-b8-fast.txt
If the focused range still does not reproduce it, rerun the longer sweep from
0xA0-0xB8 rather than the full 0x00-0xFF range:
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0xA0-0xB8" --states 0x00 --values 0x80 --after-each 0.6 --stop-on-anomaly --log captures/rcp-direct-cmd-a0-b8-replay.txt
2026-05-13 B0-B8 Focused Replay Hit
Capture:
captures/rcp-direct-cmd-b0-b8-replay.txt
Replay shape:
p1=0x00p2=0x00cmd=0xB0-0xB8state=0x00value=0x80after-each=0.6- Stop on first raw RX anomaly.
Important result:
- The sweep sent
cmd=0xB0, thencmd=0xB1. - The anomaly was captured in the read window immediately after transmitting
cmd=0xB1:00 00 B1 00 80 6B. - The RCP emitted one checksum-valid non-heartbeat frame:
07 80 6C 20 D8 49. - The final read window returned to heartbeat-only traffic.
Checksum check:
5A xor 07 xor 80 xor 6C xor 20 xor D8 = 49.
Comparison with the earlier full sweep hit:
| Trigger window | RCP response |
|---|---|
After cmd=0xB1 in focused B0-B8 replay |
07 80 6C 20 D8 49 |
After cmd=0xB5 in full 00-FF sweep |
07 80 6D 20 D8 48 |
Interpretation:
- The non-heartbeat response is reproducible with a short local sequence, so it
does not require the entire
0x00-0xFFsweep history. - The response may be sequence-dependent:
B1alone is not yet proven as the trigger becauseB0was sent one window earlier. - The response command byte changed from
0x6Dto0x6C, which suggests the RCP may be returning a status/identity code related to the host command or to internal state.
Recommended tight confirmations:
python scripts/serial_probe_response.py --port COM5 --tx-frame "00 00 B0 00 80 6A" --repeat 1 --delay 1.5 --after 5 --frame-size 0 --log captures/rcp-confirm-cmd-b0-raw.txt
python scripts/serial_probe_response.py --port COM5 --tx-frame "00 00 B1 00 80 6B" --repeat 1 --delay 1.5 --after 5 --frame-size 0 --log captures/rcp-confirm-cmd-b1-raw.txt
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0xB0-0xB1" --states 0x00 --values 0x80 --after-each 0.6 --stop-on-anomaly --log captures/rcp-direct-cmd-b0-b1-replay.txt
If B1 alone is heartbeat-only but B0-B1 reproduces the response, treat
B0 -> B1 as a required two-frame sequence.
2026-05-13 B0/B1 Tight Confirmation Result
Captures:
captures/rcp-confirm-cmd-b0-raw.txtcaptures/rcp-confirm-cmd-b1-raw.txtcaptures/rcp-direct-cmd-b0-b1-replay.txt
Results:
| Test | Pin 4 result |
|---|---|
Single B0: 00 00 B0 00 80 6A |
heartbeat only |
Single B1: 00 00 B1 00 80 6B |
heartbeat only |
Sequence B0 -> B1 |
heartbeat only, Anomalies: 0 |
Interpretation:
- The
07 80 6C 20 D8 49response from theB0-B8replay did not reproduce with the minimalB0 -> B1sequence. - The response may be intermittent, cadence-sensitive, dependent on a longer
sequence such as
B0-B8, or affected by panel state that was not identical between runs. - The next priority is measuring reproducibility of the same short range rather than expanding the search space.
Recommended reproducibility test:
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0xB0-0xB8" --states 0x00 --values 0x80 --after-each 0.6 --cycles 5 --cycle-pause 2 --log captures/rcp-direct-cmd-b0-b8-cycles.txt
Run this without --stop-on-anomaly so all five cycles complete and the log can
show whether the response happens consistently, intermittently, or only once.
Power-Cycle Isolation Test Plan
Use this plan when intentionally power-cycling the RCP between tests. The goal is to distinguish a cold-boot reproducible protocol response from a response that only appears after accumulated parser/session state.
Before each test:
- Stop any serial script.
- Power off the RCP.
- Wait at least 5 seconds.
- Power on the RCP.
- Wait until the panel is stable and heartbeat traffic has resumed.
- Run exactly one test command.
Keep the wiring and series resistor the same between tests unless the test name explicitly says otherwise.
Set A: Cold-Boot Reproducibility
Run these first. They test whether the B0-B8 response is repeatable from a
fresh power cycle.
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0xB0-0xB8" --states 0x00 --values 0x80 --settle 3 --after-each 0.6 --stop-on-anomaly --log captures/rcp-powercycle-a1-b0-b8.txt
Power-cycle, then:
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0xB0-0xB8" --states 0x00 --values 0x80 --settle 3 --after-each 0.6 --stop-on-anomaly --log captures/rcp-powercycle-a2-b0-b8.txt
Power-cycle, then:
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0xB0-0xB8" --states 0x00 --values 0x80 --settle 3 --after-each 0.6 --stop-on-anomaly --log captures/rcp-powercycle-a3-b0-b8.txt
Expected useful outcomes:
- If all three produce the same response, the sequence is cold-boot reproducible.
- If only some produce a response, the behavior may be timing-sensitive or intermittent.
- If none produce a response, the earlier hit likely depended on prior panel state.
Set B: Minimum Sequence Length
Run this set only if Set A produces at least one response. Power-cycle between each command. These tests find the shortest command prefix that can trigger a non-heartbeat response.
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0xB0-0xB1" --states 0x00 --values 0x80 --settle 3 --after-each 0.6 --stop-on-anomaly --log captures/rcp-powercycle-b1-b0-b1.txt
Power-cycle, then:
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0xB0-0xB2" --states 0x00 --values 0x80 --settle 3 --after-each 0.6 --stop-on-anomaly --log captures/rcp-powercycle-b2-b0-b2.txt
Power-cycle, then:
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0xB0-0xB3" --states 0x00 --values 0x80 --settle 3 --after-each 0.6 --stop-on-anomaly --log captures/rcp-powercycle-b3-b0-b3.txt
Power-cycle, then:
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0xB0-0xB4" --states 0x00 --values 0x80 --settle 3 --after-each 0.6 --stop-on-anomaly --log captures/rcp-powercycle-b4-b0-b4.txt
Set C: Cadence Sensitivity
Run this set if Set A is inconsistent or if Set B does not identify a clean minimum sequence. Power-cycle between each command.
Slow cadence:
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0xB0-0xB8" --states 0x00 --values 0x80 --settle 3 --after-each 1.2 --stop-on-anomaly --log captures/rcp-powercycle-c1-b0-b8-slow.txt
Fast cadence:
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0xB0-0xB8" --states 0x00 --values 0x80 --settle 3 --after-each 0.25 --stop-on-anomaly --log captures/rcp-powercycle-c2-b0-b8-fast.txt
Very fast cadence:
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0xB0-0xB8" --states 0x00 --values 0x80 --settle 3 --after-each 0.1 --stop-on-anomaly --log captures/rcp-powercycle-c3-b0-b8-very-fast.txt
Set D: Control Tests
Run these if the B0-B8 range is producing responses. Power-cycle between
each command. These confirm the response is specific to the B0 range.
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0xA8-0xAF" --states 0x00 --values 0x80 --settle 3 --after-each 0.6 --stop-on-anomaly --log captures/rcp-powercycle-d1-a8-af-control.txt
Power-cycle, then:
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0xB8-0xBF" --states 0x00 --values 0x80 --settle 3 --after-each 0.6 --stop-on-anomaly --log captures/rcp-powercycle-d2-b8-bf-control.txt
If a response appears in control ranges too, the trigger may be a broader
command class rather than a specific B0-B8 sequence.
2026-05-13 Power-Cycle Set A Result
Captures:
captures/rcp-powercycle-a1-b0-b8.txtcaptures/rcp-powercycle-a2-b0-b8.txtcaptures/rcp-powercycle-a3-b0-b8.txt
Each run was performed after a panel power cycle. All three runs produced the same non-heartbeat response.
| Run | Trigger window | RCP response | Result |
|---|---|---|---|
| A1 | after B1: 00 00 B1 00 80 6B |
07 80 6C 20 D8 49 repeated |
anomaly |
| A2 | after B1: 00 00 B1 00 80 6B |
07 80 6C 20 D8 49 repeated |
anomaly |
| A3 | after B1: 00 00 B1 00 80 6B |
07 80 6C 20 D8 49 repeated |
anomaly |
Observed raw pattern in each run:
07 80 6C 20 D8 49
07 80 6C 20 D8 49
07 80 6C 20 D8 49
...
00 00 00 00 80 DA
Interpretation:
- The
B0-B8response is cold-boot reproducible. - The response appears immediately after the
B1transmit window when the test starts from a fresh power cycle. - The earlier
B0 -> B1heartbeat-only result was likely affected by panel state from previous experiments, timing, or not starting from an equivalent cold condition. - The next test should determine whether
B0 -> B1is sufficient from a fresh power cycle, or whether the script/test context of theB0-B8run matters.
Recommended next power-cycle tests:
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0xB0-0xB1" --states 0x00 --values 0x80 --settle 3 --after-each 0.6 --stop-on-anomaly --log captures/rcp-powercycle-b1-b0-b1.txt
Power-cycle, then:
python scripts/serial_probe_response.py --port COM5 --tx-frame "00 00 B1 00 80 6B" --repeat 1 --delay 3 --after 5 --frame-size 0 --log captures/rcp-powercycle-b1-alone-raw.txt
If B0-B1 reproduces but B1 alone does not, treat B0 -> B1 as the minimum
cold-boot sequence.
2026-05-13 Minimum Cold-Boot Sequence Result
Captures:
captures/rcp-powercycle-b0.txtcaptures/rcp-powercycle-b1-b0-b1.txtcaptures/rcp-powercycle-b1-alone-raw.txt
Each test was run after a panel power cycle.
| Test | TX frame(s) | Pin 4 result |
|---|---|---|
B0 alone |
00 00 B0 00 80 6A |
heartbeat only, Anomalies: 0 |
B1 alone |
00 00 B1 00 80 6B |
heartbeat only |
B0 -> B1 |
00 00 B0 00 80 6A, then 00 00 B1 00 80 6B |
07 80 6C 20 D8 49 repeated |
Conclusion:
- The minimum confirmed cold-boot trigger is the two-frame sequence:
Host -> RCP: 00 00 B0 00 80 6A
Host -> RCP: 00 00 B1 00 80 6B
RCP -> Host: 07 80 6C 20 D8 49
- Neither
B0norB1is sufficient alone from a cold panel. B0appears to prime the panel, andB1completes the query/trigger.- The response repeats for a short period, then the panel returns to the normal
heartbeat
00 00 00 00 80 DA.
Recommended next tests:
- Timing sensitivity between
B0andB1. - State/value sensitivity of the
B0 -> B1pair. - Whether the response changes when sending nearby pairs such as
B1 -> B2,B2 -> B3, etc.
Suggested timing tests, with power cycle between each:
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0xB0-0xB1" --states 0x00 --values 0x80 --settle 3 --after-each 0.1 --stop-on-anomaly --log captures/rcp-powercycle-timing-b0-b1-100ms.txt
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0xB0-0xB1" --states 0x00 --values 0x80 --settle 3 --after-each 1.2 --stop-on-anomaly --log captures/rcp-powercycle-timing-b0-b1-1200ms.txt
Suggested nearby-pair tests, with power cycle between each:
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0xB1-0xB2" --states 0x00 --values 0x80 --settle 3 --after-each 0.6 --stop-on-anomaly --log captures/rcp-powercycle-pair-b1-b2.txt
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0xB2-0xB3" --states 0x00 --values 0x80 --settle 3 --after-each 0.6 --stop-on-anomaly --log captures/rcp-powercycle-pair-b2-b3.txt
2026-05-13 B0-B1 Timing Result
Captures:
captures/rcp-powercycle-timing-b0-b1-100ms.txtcaptures/rcp-powercycle-timing-b0-b1-1200ms.txt
Each test was run after a panel power cycle.
| B0-to-B1 spacing | RCP response |
|---|---|
| about 100 ms | 07 80 6C 20 D8 49 |
| about 1200 ms | 07 80 6C 20 D8 49 repeated |
Interpretation:
- The
B0 -> B1trigger is not tightly timing-sensitive across the tested range. B0appears to prime a state that remains valid for at least about 1.2 seconds.- The sequence order is more important than exact short timing.
Recommended next tests:
Power-cycle between each test. Check whether the trigger is specific to the
B0 -> B1 pair or whether nearby ordered pairs also trigger related responses:
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0xB1-0xB2" --states 0x00 --values 0x80 --settle 3 --after-each 0.6 --stop-on-anomaly --log captures/rcp-powercycle-pair-b1-b2.txt
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0xB2-0xB3" --states 0x00 --values 0x80 --settle 3 --after-each 0.6 --stop-on-anomaly --log captures/rcp-powercycle-pair-b2-b3.txt
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0xAF-0xB0" --states 0x00 --values 0x80 --settle 3 --after-each 0.6 --stop-on-anomaly --log captures/rcp-powercycle-pair-af-b0.txt
2026-05-13 Nearby Pair Results
Captures:
captures/rcp-powercycle-pair-af-b0.txtcaptures/rcp-powercycle-pair-b1-b2.txtcaptures/rcp-powercycle-pair-b2-b3.txt
Each test was run after a panel power cycle.
| Host pair | Second frame window | RCP response |
|---|---|---|
AF -> B0 |
00 00 B0 00 80 6A |
07 80 6C 60 30 E1 repeated |
B1 -> B2 |
00 00 B2 00 80 68 |
07 80 36 10 0C F7 repeated |
B2 -> B3 |
00 00 B3 00 80 69 |
07 80 36 10 2C D7 repeated |
Previously confirmed:
| Host pair | Second frame window | RCP response |
|---|---|---|
B0 -> B1 |
00 00 B1 00 80 6B |
07 80 6C 20 D8 49 repeated |
Checksum checks:
07 80 6C 60 30 E1: checksum valid.07 80 36 10 0C F7: checksum valid.07 80 36 10 2C D7: checksum valid.
Interpretation:
- The RCP responds to multiple adjacent two-frame host sequences in the
AF-B3region, not onlyB0 -> B1. - The response appears in the read window after the second frame of each pair.
- The response payload changes by pair, which suggests these are real command queries or status reads rather than a generic link-present acknowledgement.
- The repeated response pattern still returns to the normal heartbeat afterward.
Emerging map:
| Host sequence | RCP response fields |
|---|---|
AF -> B0 |
p1=07 p2=80 cmd=6C state=60 value=30 checksum=E1 |
B0 -> B1 |
p1=07 p2=80 cmd=6C state=20 value=D8 checksum=49 |
B1 -> B2 |
p1=07 p2=80 cmd=36 state=10 value=0C checksum=F7 |
B2 -> B3 |
p1=07 p2=80 cmd=36 state=10 value=2C checksum=D7 |
Recommended next tests:
Power-cycle between each. First continue the adjacent-pair map:
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0xB3-0xB4" --states 0x00 --values 0x80 --settle 3 --after-each 0.6 --stop-on-anomaly --log captures/rcp-powercycle-pair-b3-b4.txt
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0xB4-0xB5" --states 0x00 --values 0x80 --settle 3 --after-each 0.6 --stop-on-anomaly --log captures/rcp-powercycle-pair-b4-b5.txt
Then test whether adjacency and order matter:
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0xB0 0xB2" --states 0x00 --values 0x80 --settle 3 --after-each 0.6 --stop-on-anomaly --log captures/rcp-powercycle-pair-b0-b2-skip.txt
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0xB1 0xB0" --states 0x00 --values 0x80 --settle 3 --after-each 0.6 --stop-on-anomaly --log captures/rcp-powercycle-pair-b1-b0-reverse.txt
2026-05-13 Additional Pair/Control Results
User observation:
- All tests still showed
CONNECT NOT ACTon the RCP/CCU screen, with no other visible state change.
Serial captures:
captures/rcp-powercycle-pair-b3-b4.txtcaptures/rcp-powercycle-pair-b4-b5.txtcaptures/rcp-powercycle-pair-b0-b2-skip.txtcaptures/rcp-powercycle-pair-b1-b0-reverse.txt
Each test was run after a panel power cycle.
| Host pair | Second frame window | RCP response |
|---|---|---|
B3 -> B4 |
00 00 B4 00 80 6E |
07 80 6D 40 30 C0 repeated |
B4 -> B5 |
00 00 B5 00 80 6F |
07 80 6D 20 D8 48 repeated |
B0 -> B2 |
00 00 B2 00 80 68 |
07 80 36 10 0C F7 repeated |
B1 -> B0 |
00 00 B0 00 80 6A |
07 80 6C 40 30 C1 repeated |
Interpretation:
- The screen state remains
CONNECT NOT ACT, but pin 4 responses are changing in a structured, checksum-valid way. - The skip test
B0 -> B2produced the same response asB1 -> B2, so the second command may be the main selector once any valid priming frame is sent. - The reverse test
B1 -> B0also produced a valid response, so strict ascending adjacency is not required. - Current model: a first host frame primes/enters a response mode, and the second host frame selects a status/query response.
Expanded observed response map:
| Second host command | Observed response(s) |
|---|---|
B0 |
07 80 6C 60 30 E1 after AF -> B0; 07 80 6C 40 30 C1 after B1 -> B0 |
B1 |
07 80 6C 20 D8 49 after B0 -> B1 |
B2 |
07 80 36 10 0C F7 after B1 -> B2 and B0 -> B2 |
B3 |
07 80 36 10 2C D7 after B2 -> B3 |
B4 |
07 80 6D 40 30 C0 after B3 -> B4 |
B5 |
07 80 6D 20 D8 48 after B4 -> B5 |
Recommended next tests:
Power-cycle between each. Test whether a generic primer plus selected second command is enough:
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0x00 0xB0" --states 0x00 --values 0x80 --settle 3 --after-each 0.6 --stop-on-anomaly --log captures/rcp-powercycle-primer-00-b0.txt
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0x00 0xB2" --states 0x00 --values 0x80 --settle 3 --after-each 0.6 --stop-on-anomaly --log captures/rcp-powercycle-primer-00-b2.txt
Then map the next selected second commands:
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0xB5-0xB6" --states 0x00 --values 0x80 --settle 3 --after-each 0.6 --stop-on-anomaly --log captures/rcp-powercycle-pair-b5-b6.txt
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0xB6-0xB7" --states 0x00 --values 0x80 --settle 3 --after-each 0.6 --stop-on-anomaly --log captures/rcp-powercycle-pair-b6-b7.txt
2026-05-13 Generic Primer and B6-B7 Results
Captures:
captures/rcp-powercycle-primer-00-b0.txtcaptures/rcp-powercycle-primer-00-b2.txtcaptures/rcp-powercycle-pair-b5-b6.txtcaptures/rcp-powercycle-pair-b6-b7.txt
Each test was run after a panel power cycle.
| Host pair | Second frame window | RCP response |
|---|---|---|
00 -> B0 |
00 00 B0 00 80 6A |
07 80 6C 40 30 C1 repeated |
00 -> B2 |
00 00 B2 00 80 68 |
07 80 36 10 0C F7 repeated |
B5 -> B6 |
00 00 B6 00 80 6C |
07 80 1B 08 C6 08 repeated |
B6 -> B7 |
00 00 B7 00 80 6D |
07 80 1B 08 D6 18 repeated |
Checksum checks:
07 80 6C 40 30 C1: checksum valid.07 80 36 10 0C F7: checksum valid.07 80 1B 08 C6 08: checksum valid.07 80 1B 08 D6 18: checksum valid.
Interpretation:
00 -> B0produced the same response asB1 -> B0.00 -> B2produced the same response asB0 -> B2andB1 -> B2.- This supports the model that the first frame can be a generic valid primer, and the second frame selects the response.
- The
B6andB7selected responses introduce another response command class (cmd=0x1B) with changing value bytes.
Updated selected-command map:
| Selected second command | Observed response |
|---|---|
B0 |
07 80 6C 40 30 C1 after 00 -> B0 and B1 -> B0; 07 80 6C 60 30 E1 after AF -> B0 |
B1 |
07 80 6C 20 D8 49 after B0 -> B1 |
B2 |
07 80 36 10 0C F7 after 00 -> B2, B0 -> B2, and B1 -> B2 |
B3 |
07 80 36 10 2C D7 after B2 -> B3 |
B4 |
07 80 6D 40 30 C0 after B3 -> B4 |
B5 |
07 80 6D 20 D8 48 after B4 -> B5 |
B6 |
07 80 1B 08 C6 08 after B5 -> B6 |
B7 |
07 80 1B 08 D6 18 after B6 -> B7 |
Recommended next controls:
Power-cycle between each. First prove whether B2, B6, and B7 need a
primer, or whether they can respond as single frames from cold boot:
python scripts/serial_direct_response_sweep.py --port COM5 --commands 0xB2 --states 0x00 --values 0x80 --settle 3 --after-each 0.6 --stop-on-anomaly --log captures/rcp-powercycle-single-b2.txt
python scripts/serial_direct_response_sweep.py --port COM5 --commands 0xB6 --states 0x00 --values 0x80 --settle 3 --after-each 0.6 --stop-on-anomaly --log captures/rcp-powercycle-single-b6.txt
python scripts/serial_direct_response_sweep.py --port COM5 --commands 0xB7 --states 0x00 --values 0x80 --settle 3 --after-each 0.6 --stop-on-anomaly --log captures/rcp-powercycle-single-b7.txt
Then continue the selected-command map using 00 as the primer:
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0x00 0xB3" --states 0x00 --values 0x80 --settle 3 --after-each 0.6 --stop-on-anomaly --log captures/rcp-powercycle-primer-00-b3.txt
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0x00 0xB4" --states 0x00 --values 0x80 --settle 3 --after-each 0.6 --stop-on-anomaly --log captures/rcp-powercycle-primer-00-b4.txt
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0x00 0xB5" --states 0x00 --values 0x80 --settle 3 --after-each 0.6 --stop-on-anomaly --log captures/rcp-powercycle-primer-00-b5.txt
2026-05-13 Single-Frame and One-Shot Primer Results
Captures:
captures/rcp-powercycle-single-b2.txtcaptures/rcp-powercycle-single-b6.txtcaptures/rcp-powercycle-single-b7.txtcaptures/rcp-powercycle-primer-00-b3.txtcaptures/rcp-powercycle-primer-00-b4.txtcaptures/rcp-powercycle-primer-00-b5.txt
Single-frame controls, each after a panel power cycle:
| Test | Pin 4 result |
|---|---|
B2 alone |
heartbeat only, Anomalies: 0 |
B6 alone |
heartbeat only, Anomalies: 0 |
B7 alone |
heartbeat only, Anomalies: 0 |
Generic-primer map, each first run after a panel power cycle:
| Host pair | Second frame window | RCP response |
|---|---|---|
00 -> B3 |
00 00 B3 00 80 69 |
07 80 36 10 2C D7 repeated |
00 -> B4 |
00 00 B4 00 80 6E |
07 80 6D 40 30 C0 |
00 -> B5 |
00 00 B5 00 80 6F |
07 80 6D 20 D8 48 repeated |
Repeated 00 -> B5 without power-cycling:
| Attempt | Power cycle before attempt? | Result |
|---|---|---|
| 1 | yes | 07 80 6D 20 D8 48 repeated |
| 2 | no | heartbeat only, Anomalies: 0 |
| 3 | no | heartbeat only, Anomalies: 0 |
Interpretation:
- A single selected command is not enough; the panel requires a preceding valid primer frame.
00works as a primer forB0,B2,B3,B4, andB5.- The same primed query may be one-shot after power-up. After
00 -> B5returns its response, repeating00 -> B5without power-cycling does not produce another non-heartbeat response. - Future mapping should power-cycle before each selected-command test unless intentionally studying latch/repeat behavior.
Current generic-primer selected-command map:
| Host query | RCP response |
|---|---|
00 -> B0 |
07 80 6C 40 30 C1 |
00 -> B2 |
07 80 36 10 0C F7 |
00 -> B3 |
07 80 36 10 2C D7 |
00 -> B4 |
07 80 6D 40 30 C0 |
00 -> B5 |
07 80 6D 20 D8 48 |
Recommended next tests:
Power-cycle before each query. Fill the missing 00 -> B1 entry and continue
the 00 -> selected map:
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0x00 0xB1" --states 0x00 --values 0x80 --settle 3 --after-each 0.6 --stop-on-anomaly --log captures/rcp-powercycle-primer-00-b1.txt
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0x00 0xB6" --states 0x00 --values 0x80 --settle 3 --after-each 0.6 --stop-on-anomaly --log captures/rcp-powercycle-primer-00-b6.txt
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0x00 0xB7" --states 0x00 --values 0x80 --settle 3 --after-each 0.6 --stop-on-anomaly --log captures/rcp-powercycle-primer-00-b7.txt
Optional latch test, without power-cycling after the first run:
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0x00 0xB5" --states 0x00 --values 0x80 --settle 3 --after-each 0.6 --cycles 3 --cycle-pause 2 --log captures/rcp-latch-primer-00-b5-cycles.txt
Current Inferred Behavior
The current evidence suggests the RCP is entering a discovery/query/status-read phase, not a completed active-control handshake.
Working model:
Host/CCU -> RCP: valid primer frame
Host/CCU -> RCP: selected query/status command
RCP -> Host/CCU: checksum-valid response frame repeated briefly
RCP -> Host/CCU: returns to heartbeat
Important details:
- Single selected commands such as
B2,B6, andB7do not respond from a cold panel. - A preceding valid frame is required.
00 00 00 00 80 DAworks as a generic primer for several selected commands. - The second command selects the response payload.
- The LCD can remain
CONNECT NOT ACTwhile serial responses vary in a structured way. Serial response does not yet mean the active control session is accepted. - At least some primed queries appear one-shot after power-up. Repeating the same primed query without power-cycling can produce only heartbeat traffic.
Likely protocol role:
- These
B0-range commands may be a CCU discovery or capability/status query phase. - The CCU may query RCP model/capability/state blocks before sending a later activation/session command.
- The next unknown is the command or command sequence that follows these
discovery responses and moves the panel from
CONNECT NOT ACTto active.
Primer-Candidate Broad Sweep
Use scripts/serial_primer_candidate_sweep.py for broader searches based on
the current primer/query model. It sends:
primer frame -> candidate frame -> raw RX classification
For clean mapping, use --prompt-power-cycle and power-cycle before each
candidate. This avoids the one-shot/latch behavior contaminating later
candidates.
Example dry run:
python scripts/serial_primer_candidate_sweep.py --port COM5 --candidates "0xB0-0xB7" --dry-run
Continue the known B range first:
python scripts/serial_primer_candidate_sweep.py --port COM5 --candidates "0xB1 0xB6 0xB7 0xB8 0xB9 0xBA 0xBB 0xBC 0xBD 0xBE 0xBF" --prompt-power-cycle --stop-on-anomaly --log captures/rcp-primer-sweep-b1-bf.txt
Because --stop-on-anomaly stops at the first response, after each hit:
- Save the reported candidate and response frame.
- Power-cycle the panel.
- Restart the sweep from the next unmapped candidate.
For non-stop mapping, omit --stop-on-anomaly, but still power-cycle at each
prompt:
python scripts/serial_primer_candidate_sweep.py --port COM5 --candidates "0xB8-0xBF" --prompt-power-cycle --log captures/rcp-primer-sweep-b8-bf.txt
Suggested broad ranges after B0-BF:
python scripts/serial_primer_candidate_sweep.py --port COM5 --candidates "0xA0-0xAF" --prompt-power-cycle --log captures/rcp-primer-sweep-a0-af.txt
python scripts/serial_primer_candidate_sweep.py --port COM5 --candidates "0xC0-0xCF" --prompt-power-cycle --log captures/rcp-primer-sweep-c0-cf.txt
python scripts/serial_primer_candidate_sweep.py --port COM5 --candidates "0x00-0x1F" --prompt-power-cycle --log captures/rcp-primer-sweep-00-1f.txt
Recommended first run:
python scripts/serial_primer_candidate_sweep.py --port COM5 --candidates "0xB1 0xB6 0xB7 0xB8 0xB9 0xBA 0xBB 0xBC 0xBD 0xBE 0xBF" --prompt-power-cycle --log captures/rcp-primer-sweep-b1-bf.txt
Primer Reuse and Sequential Query Tests
Two open questions:
- After a cold boot, does the RCP only answer one selected query before it latches/suppresses further responses?
- Is a fresh primer required before every selected query, or can one primer unlock several selected commands in sequence?
Use scripts/serial_direct_response_sweep.py for these tests because it can
send arbitrary command sequences without stopping between commands. For each
test below, power-cycle once before starting the script, then do not power-cycle
again until the script exits.
Test S1: One Primer, Multiple Different Queries
Purpose: test whether one primer can unlock several different selected commands.
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0x00 0xB2 0xB3 0xB4 0xB5" --states 0x00 --values 0x80 --settle 3 --after-each 0.8 --log captures/rcp-seq-one-primer-b2-b5.txt
Interpretation:
- If only
B2responds, the panel likely allows one selected response per cold-boot/primer state. - If
B2,B3,B4, andB5all respond, one primer can unlock multiple sequential queries. - If some respond and some do not, there may be command-group or latch behavior.
Test S2: Primer Before Every Query, No Power Cycle
Purpose: test whether a new primer can re-arm another selected query without power-cycling.
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0x00 0xB2 0x00 0xB3 0x00 0xB4 0x00 0xB5" --states 0x00 --values 0x80 --settle 3 --after-each 0.8 --log captures/rcp-seq-reprimer-b2-b5.txt
Interpretation:
- If every selected command responds, a primer is required before each query but power-cycling is not.
- If only the first selected command responds, power-cycle or another reset-like command may be required to clear the latch.
Test S3: Repeat Same Query With and Without Reprimer
Purpose: test whether the same selected query can be repeated in one powered session.
Without re-primer:
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0x00 0xB5 0xB5 0xB5" --states 0x00 --values 0x80 --settle 3 --after-each 0.8 --log captures/rcp-seq-repeat-b5-no-reprimer.txt
Power-cycle, then with re-primer:
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0x00 0xB5 0x00 0xB5 0x00 0xB5" --states 0x00 --values 0x80 --settle 3 --after-each 0.8 --log captures/rcp-seq-repeat-b5-reprimer.txt
Interpretation:
- If only the first
B5responds in both tests, the response is one-shot until power cycle or a yet-unknown reset/ack command. - If the re-primer version responds repeatedly, the primer re-arms the selected query.
2026-05-13 Sequential Query Test Result
Captures:
captures/rcp-seq-one-primer-b2-b5.txtcaptures/rcp-seq-reprimer-b2-b5.txtcaptures/rcp-seq-repeat-b5-no-reprimer.txtcaptures/rcp-seq-repeat-b5-reprimer.txt
Valid result:
| Test | Intended sequence | Actual sequence sent | Result |
|---|---|---|---|
| S1 | 00 -> B2 -> B3 -> B4 -> B5 |
00 -> B2 -> B3 -> B4 -> B5 |
only B2 responded: 07 80 36 10 0C F7 |
Tooling caveat:
- The original
serial_direct_response_sweep.pyde-duplicated command lists. - Because of that, sequences containing repeated commands did not run as intended.
S2,S3 no re-primer, andS3 re-primerneed to be rerun after the script fix.- The script has been updated to preserve repeated command values in explicit command lists.
Interpretation from S1:
- One primer did not unlock a whole list of feature/status queries.
- After
00 -> B2returned07 80 36 10 0C F7, laterB3,B4, andB5in the same powered session did not produce additional non-heartbeat frames. - This supports a one-response latch model unless the re-primer test proves that the primer can re-arm another query.
Rerun these tests after the script fix:
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0x00 0xB2 0x00 0xB3 0x00 0xB4 0x00 0xB5" --states 0x00 --values 0x80 --settle 3 --after-each 0.8 --log captures/rcp-seq-reprimer-b2-b5-v2.txt
Power-cycle, then:
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0x00 0xB5 0xB5 0xB5" --states 0x00 --values 0x80 --settle 3 --after-each 0.8 --log captures/rcp-seq-repeat-b5-no-reprimer-v2.txt
Power-cycle, then:
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0x00 0xB5 0x00 0xB5 0x00 0xB5" --states 0x00 --values 0x80 --settle 3 --after-each 0.8 --log captures/rcp-seq-repeat-b5-reprimer-v2.txt
2026-05-13 Sequential Query Rerun Result
Captures:
captures/rcp-seq-reprimer-b2-b5-v2.txtcaptures/rcp-seq-repeat-b5-no-reprimer-v2.txtcaptures/rcp-seq-repeat-b5-reprimer-v2.txt
These reruns used the fixed serial_direct_response_sweep.py, which preserves
repeated command values in explicit sequences.
Results:
| Test | Sequence | Non-heartbeat response(s) |
|---|---|---|
| Re-primer between different queries | 00 -> B2 -> 00 -> B3 -> 00 -> B4 -> 00 -> B5 |
only B2: 07 80 36 10 0C F7 |
Repeat B5, no re-primer |
00 -> B5 -> B5 -> B5 |
only first B5: 07 80 6D 20 D8 48 |
Repeat B5, re-primer each time |
00 -> B5 -> 00 -> B5 -> 00 -> B5 |
only first B5: 07 80 6D 20 D8 48 |
Interpretation:
- The RCP appears to allow only one selected query response per powered session
in the current
CONNECT NOT ACTstate. - Sending another primer (
00 00 00 00 80 DA) after the first response does not re-arm the query responder. - Repeating the same selected query does not produce another response.
- This strongly suggests a one-shot discovery/status response followed by a required next-stage command, acknowledgement, reset, or activation step.
Implication for CCU behavior:
- The CCU may not scan a list of feature queries in the current state. It may send one discovery/status query, receive one response, then decide what activation/session command to send next.
- Alternatively, additional feature reads may require an acknowledgement or state-advance command that has not yet been identified.
Recommended next direction:
- Stop broad feature scanning for the moment.
- Search for the post-discovery acknowledgement/activation command that follows
one known response such as
00 -> B5 => 07 80 6D 20 D8 48. - Use a three-step pattern:
primer -> selected query -> candidate activation/ack command
Known reproducible setup:
Host -> RCP: 00 00 00 00 80 DA
Host -> RCP: 00 00 B5 00 80 6F
RCP -> Host: 07 80 6D 20 D8 48
Host -> RCP: candidate next-stage command
Post-Discovery Candidate Sweep
Use scripts/serial_post_discovery_sweep.py to search for the command that
comes after one known discovery/status response. This is the likely next stage
after the one-shot response behavior.
Default setup:
primer: 00 00 00 00 80 DA
query: 00 00 B5 00 80 6F
RCP: 07 80 6D 20 D8 48
then: candidate next-stage command
Recommended first post-discovery sweep:
python scripts/serial_post_discovery_sweep.py --port COM5 --candidates "0x00-0x1F" --prompt-power-cycle --prompt-screen --log captures/rcp-post-discovery-b5-candidates-00-1f.txt
For each candidate:
- Power-cycle the RCP.
- Wait for heartbeat/panel stable.
- Press Enter at the prompt.
- Watch for any screen change after the candidate frame.
- Type the screen state if it changes, or press Enter for no visible change.
Why this range first:
- Earlier frame-length tests showed small command values can change screen state
to
CONNECT NOT ACT. - If a simple ACK/activation command exists, it may be in the low command range.
Next ranges if 00-1F does not change state:
python scripts/serial_post_discovery_sweep.py --port COM5 --candidates "0x20-0x3F" --prompt-power-cycle --prompt-screen --log captures/rcp-post-discovery-b5-candidates-20-3f.txt
python scripts/serial_post_discovery_sweep.py --port COM5 --candidates "0x80-0x9F" --prompt-power-cycle --prompt-screen --log captures/rcp-post-discovery-b5-candidates-80-9f.txt
python scripts/serial_post_discovery_sweep.py --port COM5 --candidates "0xB0-0xBF" --prompt-power-cycle --prompt-screen --log captures/rcp-post-discovery-b5-candidates-b0-bf.txt
If any candidate changes the screen away from CONNECT NOT ACT, or produces a
new RCP response after the candidate stage, retest that candidate alone with
three fresh power cycles.
2026-05-13 Post-Discovery Sweep 00-1F Result
Capture:
captures/rcp-post-discovery-b5-candidates-00-1f.txt
Sweep setup:
primer: 00 00 00 00 80 DA
query: 00 00 B5 00 80 6F
expected: 07 80 6D 20 D8 48
candidate: 00-1F
Screen result:
- Every candidate remained at
CONNECT NOT ACT/CONNECTION NOT ACT. - No candidate in
0x00-0x1Fmoved the panel into an active state.
Serial result:
- Most candidates produced only heartbeat-compatible traffic after the candidate frame.
- Candidate windows for
0x00,0x0E,0x0F,0x1A,0x1E, and0x1Fincluded additional bytes matching the known discovery response07 80 6D 20 D8 48. - Those candidate-window anomalies are likely trailing/repeated discovery
response frames from the
B5query, not new candidate-specific responses.
Notable outlier:
- During candidate
0x03, the primer read window contained07 80 40 40 30 ED, followed by heartbeat. - This is checksum-valid, but it occurred before the
B5query in that test window. Treat it as an outlier until reproduced. Possible explanations include incomplete power-cycle reset, a previous state/latch edge, or an accidental timing artifact.
Interpretation:
- Low command range
0x00-0x1Fdoes not appear to contain the simple post-discovery activation command when tested after theB5discovery query. - The script's candidate read window can still catch residual discovery response frames; candidate anomalies must be checked against the known query response before treating them as new behavior.
Recommended next sweep:
Use a slightly longer query read window so the known discovery response has more time to finish before the candidate frame:
python scripts/serial_post_discovery_sweep.py --port COM5 --candidates "0x20-0x3F" --after-query 2.0 --prompt-power-cycle --prompt-screen --log captures/rcp-post-discovery-b5-candidates-20-3f.txt
If 20-3F also keeps the screen at CONNECT NOT ACT, continue:
python scripts/serial_post_discovery_sweep.py --port COM5 --candidates "0x80-0x9F" --after-query 2.0 --prompt-power-cycle --prompt-screen --log captures/rcp-post-discovery-b5-candidates-80-9f.txt
python scripts/serial_post_discovery_sweep.py --port COM5 --candidates "0xB0-0xBF" --after-query 2.0 --prompt-power-cycle --prompt-screen --log captures/rcp-post-discovery-b5-candidates-b0-bf.txt
Post-Discovery Test Ladder
Before manually sweeping every command byte, sample representative patterns from several command regions. The goal is to identify which command families are worth expanding.
Use the same known discovery setup for each sample:
primer: 00 00 00 00 80 DA
query: 00 00 B5 00 80 6F
RCP: 07 80 6D 20 D8 48
then: sampled candidate command
Power-cycle before each candidate prompt. Type any screen change, otherwise press Enter.
Ladder 1: Low-Range Sanity Sample
The full 00-1F sweep did not activate the panel, but one outlier appeared
during the 0x03 test. Retest only representative low bytes plus the outlier:
python scripts/serial_post_discovery_sweep.py --port COM5 --candidates "0x00 0x01 0x03 0x07 0x0F 0x10 0x1B 0x1F" --after-query 2.0 --prompt-power-cycle --prompt-screen --log captures/rcp-post-ladder-low-sample.txt
What this checks:
0x00,0x01: no-op / ACK-like small commands.0x03: the outlier run produced07 80 40 40 30 ED.0x07,0x0F,0x1F: bit-mask/boundary values.0x10,0x1B: response command-family values observed in RCP frames.
Ladder 2: Response-Command Echo Sample
Test host commands that match command bytes seen in RCP responses. If the CCU acknowledges or advances using related command IDs, these are good candidates.
Observed RCP response command bytes so far:
1B 36 40 6C 6D
Run:
python scripts/serial_post_discovery_sweep.py --port COM5 --candidates "0x1B 0x36 0x40 0x6C 0x6D" --after-query 2.0 --prompt-power-cycle --prompt-screen --log captures/rcp-post-ladder-response-cmds.txt
Expand only if one of these changes screen state or produces a new candidate-stage response.
Ladder 3: Boundary and Bit-Pattern Sample
This tests command bytes that often mark command classes, flags, or boundaries:
python scripts/serial_post_discovery_sweep.py --port COM5 --candidates "0x20 0x2F 0x30 0x3F 0x40 0x4F 0x50 0x5F 0x7F 0x80 0x8F 0x90 0x9F 0xA0 0xAF 0xB0 0xBF 0xC0 0xCF 0xE0 0xEF 0xF0 0xFF" --after-query 2.0 --prompt-power-cycle --prompt-screen --log captures/rcp-post-ladder-boundaries.txt
What this checks:
- Nibble/region boundaries.
- The high-bit transition at
0x80. - Known discovery query region around
0xB0. - High command space around
0xE0-0xFF.
Ladder 4: Known Query Region Sample
The B0 range is known to produce discovery/status responses when used as the
selected query. It may also contain a next-stage command.
python scripts/serial_post_discovery_sweep.py --port COM5 --candidates "0xB0 0xB1 0xB2 0xB3 0xB4 0xB5 0xB6 0xB7 0xB8 0xBF" --after-query 2.0 --prompt-power-cycle --prompt-screen --log captures/rcp-post-ladder-b-region.txt
If any B candidate changes behavior, expand locally around it rather than
sweeping the full byte space.
Ladder 5: Alternate Discovery Response Bases
If all candidate ladders after 00 -> B5 leave the screen at CONNECT NOT ACT,
try the same sampled candidates after a different discovery query. Different RCP
responses may expect different follow-up ACKs.
Use B2 discovery:
python scripts/serial_post_discovery_sweep.py --port COM5 --query-command 0xB2 --candidates "0x00 0x01 0x1B 0x36 0x40 0x6C 0x6D 0x80 0xB0 0xB5 0xFF" --after-query 2.0 --prompt-power-cycle --prompt-screen --log captures/rcp-post-ladder-after-b2.txt
Use B0 discovery:
python scripts/serial_post_discovery_sweep.py --port COM5 --query-command 0xB0 --candidates "0x00 0x01 0x1B 0x36 0x40 0x6C 0x6D 0x80 0xB0 0xB5 0xFF" --after-query 2.0 --prompt-power-cycle --prompt-screen --log captures/rcp-post-ladder-after-b0.txt
Interpretation:
- If a candidate only works after one discovery response, the next-stage command may depend on the returned block.
- If the same candidate works after multiple discovery responses, it is a stronger activation/ACK candidate.
When to Expand
Expand a region only when one of these occurs:
- Screen changes away from
CONNECT NOT ACT. - RCP sends a new candidate-stage frame that is not the known discovery response trailing into the candidate window.
- The panel begins sending different heartbeat/status frames after the candidate.
If none of the ladder samples produce a new behavior, stop command-byte guessing and test other frame fields for the candidate stage: state byte, value byte, or prefix bytes.
2026-05-13 Ladder 1 Result and Keepalive Hypothesis
Capture:
captures/rcp-post-ladder-low-sample.txt
Ladder 1 candidates:
00 01 03 07 0F 10 1B 1F
Result:
- Every sampled candidate left the screen at
CONNECT NOT ACT. - Candidate-stage RX was heartbeat-compatible for all candidates.
- The earlier
0x03outlier did not reproduce. - Query-stage response
07 80 6D 20 D8 48reproduced reliably before each candidate.
Interpretation:
- The low/outlier sample did not find a post-discovery activation/ACK command.
CONNECT NOT ACTmay be unrelated to a one-shot ACK. It may mean the RCP sees host traffic but is not receiving the correct ongoing CCU heartbeat/session cadence.
Alternative working model:
Host sends discovery/status query
RCP answers once
Host must then send a sustained keepalive/session heartbeat
RCP remains CONNECT NOT ACT until that heartbeat/cadence is correct
Keepalive After Discovery Tests
Use scripts/serial_keepalive_after_query.py to test whether a sustained host
heartbeat changes the RCP state after a known discovery response.
Default setup:
primer: 00 00 00 00 80 DA
query: 00 00 B5 00 80 6F
RCP reply: 07 80 6D 20 D8 48
keepalive: repeated candidate frame
Test K1: repeat the known primer/heartbeat shape:
python scripts/serial_keepalive_after_query.py --port COM5 --keepalive-command 0x00 --duration 15 --interval 0.6 --prompt-screen --log captures/rcp-keepalive-after-b5-cmd00-600ms.txt
Test K2: repeat the zero-state frame:
python scripts/serial_keepalive_after_query.py --port COM5 --keepalive-frame "00 00 00 00 00 5A" --duration 15 --interval 0.6 --prompt-screen --log captures/rcp-keepalive-after-b5-zero-state-600ms.txt
Test K3: repeat the alternate state frame:
python scripts/serial_keepalive_after_query.py --port COM5 --keepalive-frame "00 00 00 80 00 DA" --duration 15 --interval 0.6 --prompt-screen --log captures/rcp-keepalive-after-b5-state80-600ms.txt
Test K4: faster primer/heartbeat cadence:
python scripts/serial_keepalive_after_query.py --port COM5 --keepalive-command 0x00 --duration 15 --interval 0.2 --prompt-screen --log captures/rcp-keepalive-after-b5-cmd00-200ms.txt
Power-cycle before each keepalive test. Watch for:
- Screen changing away from
CONNECT NOT ACT. - Pin 4 changing from heartbeat to another recurring status frame.
- RCP controls beginning to transmit additional button/status data.
2026-05-13 Keepalive After Discovery Result
Captures:
captures/rcp-keepalive-after-b5-cmd00-600ms.txtcaptures/rcp-keepalive-after-b5-zero-state-600ms.txtcaptures/rcp-keepalive-after-b5-state80-600ms.txtcaptures/rcp-keepalive-after-b5-cmd00-200ms.txt
Result:
| Test | Keepalive frame | Cadence | Screen result | Pin 4 RX |
|---|---|---|---|---|
| K1 | 00 00 00 00 80 DA |
0.6 s | CONNECT NOT ACT |
heartbeat-compatible |
| K2 | 00 00 00 00 00 5A |
0.6 s | CONNECT NOT ACT |
heartbeat-compatible |
| K3 | 00 00 00 80 00 DA |
0.6 s | CONNECT NOT ACT |
heartbeat-compatible |
| K4 | 00 00 00 00 80 DA |
0.2 s | CONNECT NOT ACT |
heartbeat-compatible |
Interpretation:
- A simple sustained host heartbeat after
00 -> B5does not activate the RCP. - The RCP continues emitting only the known heartbeat-compatible stream on pin 4 during these keepalive attempts.
- The correct next stage is probably not just "repeat the primer" or "hold a no-op frame at CCU cadence".
- The better next branch is to map additional
primer -> requestcommands that cause one-shot RCP responses. Those response blocks may reveal the command families, status bits, or identity data needed for the later activation step.
Recommended next request sweep:
python scripts/serial_primer_candidate_sweep.py --port COM5 --candidates "0xB1 0xB6 0xB7 0xB8 0xB9 0xBA 0xBB 0xBC 0xBD 0xBE 0xBF" --prompt-power-cycle --log captures/rcp-primer-sweep-b1-bf.txt
Power-cycle before each candidate prompt. This fills the gaps around the known
B0-B5 discovery/status region and checks whether B8-BF contain additional
one-shot readable blocks.
If this range is quiet, continue with neighboring command regions:
python scripts/serial_primer_candidate_sweep.py --port COM5 --candidates "0xA0-0xAF" --prompt-power-cycle --log captures/rcp-primer-sweep-a0-af.txt
python scripts/serial_primer_candidate_sweep.py --port COM5 --candidates "0xC0-0xCF" --prompt-power-cycle --log captures/rcp-primer-sweep-c0-cf.txt
2026-05-13 Primer Sweep A/B/C Region Result
Captures:
captures/rcp-primer-sweep-a0-af.txtcaptures/rcp-primer-sweep-b1-bf.txcaptures/rcp-primer-sweep-c0-cf.txt
These sweeps used a fresh power cycle before each candidate, with the standard primer shape before the selected request:
primer: 00 00 00 00 80 DA
candidate: 00 00 CMD 00 80 CHECKSUM
New selected-command response map:
| Selected command | Observed RCP response |
|---|---|
A0 |
07 80 68 40 30 C5 |
A1 |
07 80 68 20 D8 4D |
A2 |
07 80 34 10 0C F5 |
A3 |
07 80 34 10 2C D5 |
A4 |
07 80 69 40 30 C4 |
A5 |
07 80 69 20 D8 4C |
A6 |
07 80 1A 08 C6 09 |
A7 |
07 80 1A 08 D6 19 |
A8 |
07 80 6A 40 30 C7 |
A9 |
07 80 6A 20 D8 4F |
AA |
07 80 35 10 0C F4 |
AB |
07 80 35 10 2C D4 |
AC |
07 80 6B 40 30 C6 |
AD |
07 80 6B 20 D8 4E |
AE |
07 80 0D 04 A3 77 |
AF |
07 80 0D 04 AB 7F |
B1 |
07 80 6C 20 D8 49 |
B6 |
07 80 1B 08 C6 08 |
B7 |
07 80 1B 08 F6 38 |
B8 |
07 80 EE 40 30 43 |
B9 |
07 80 6E 20 D8 4B |
BA |
07 80 37 10 0C F6 |
BB |
07 80 37 10 2C D6 |
BC |
07 80 EF 40 30 42 |
BD |
07 80 6F 20 D8 4A |
BE |
heartbeat only |
BF |
heartbeat only |
C0 |
heartbeat only |
C1 |
07 80 70 20 D8 55 |
C2 |
07 80 38 10 0C F9 |
C3 |
07 80 38 10 2C D9 |
C4 |
07 80 71 40 30 DC |
C5 |
07 80 71 20 D8 54 |
C6 |
07 80 1C 08 C6 0F |
C7 |
07 80 1C 08 D6 1F |
C8 |
07 80 72 40 30 DF |
C9 |
07 80 72 20 D8 57 |
CA |
07 80 39 10 0C F8 |
CB |
07 80 39 10 2C D8 |
CC |
07 80 F3 40 30 5E |
CD |
07 80 73 20 D8 56 |
CE |
07 80 0E 04 A3 74 |
CF |
07 80 0E 04 AB 7C |
Interpretation:
- The RCP has a much larger one-shot readable status/query surface than first assumed.
- The
A0-CFregion looks highly structured. Most commands return stable six-byte responses with the same07 80prefix and valid XOR checksum. - Pairs often share a response command byte and differ in state/value fields:
A0/A1,A2/A3,A4/A5,A6/A7, and similar patterns continue through theBandCregions. BE,BF, andC0are current no-response candidates in this mapping.- This strongly supports a discovery/status table model: the CCU may read a specific set of one-shot blocks, then choose a later activation/session command based on the returned table values.
2026-05-13 Paused Direct Sweep Result
Capture:
captures/rcp-direct-remaining-after-b5-pause.txt
The paused direct sweep logged anomalies and then allowed a manual power cycle
before continuing. Because the script continues with the next command after the
pause, this run is useful for finding response-producing commands, but it is
not a clean 00 -> B5 -> candidate post-discovery sweep.
Response hits observed in this run:
| Command at anomaly | Observed RCP response | Caution |
|---|---|---|
B5 |
07 80 6D 20 D8 48 |
expected known query response |
40 |
07 80 50 40 30 FD |
repeated twice in this run |
6D |
07 80 5B 20 D8 7E |
may depend on prior 6C |
4F |
07 80 0A 04 AB 78 |
needs clean one-per-boot confirmation |
8F |
07 80 0C 04 AB 7E |
may depend on prior sequence |
A0 |
07 80 E8 40 30 45 |
differs from primer-sweep A0 response |
B0 |
07 80 6C 40 30 C1 |
known response |
CF |
07 80 0E 04 AB 7C |
matches primer-sweep CF response |
EF |
07 80 0F 04 EB 3D |
needs clean one-per-boot confirmation |
B1 |
07 80 6C 20 D8 49 |
known response |
B3 |
07 80 36 10 2C D7 |
known response |
B6 |
07 80 1B 08 C6 08 |
known response |
B8 |
07 80 6E 40 30 C3 |
differs from primer-sweep B8 response |
BA |
07 80 37 10 0C F6 |
matches primer-sweep BA response |
BC |
07 80 6F 40 30 C2 |
differs from primer-sweep BC response |
Next confirmations:
- Retest
40,4F,8F,EF, and the differingA0/B8/BCcases as clean one-per-boot primer pairs. - If a response differs between a plain/direct command and a primer-pair query, treat the first host frame as a mode/context selector rather than only a generic wake-up primer.
Context Selector Confirmation Tests
Goal: confirm whether the first host frame is only a generic primer, or whether it selects a response page/context for the next command.
The test method is to hold the second/query command constant and change only the first frame:
selector/primer -> selected query
Strong confirmation:
- Same selected query, different first frame, different RCP response.
- Example pattern:
00 -> B8returns one block whileB7 -> B8returns a different block.
Weak or negative result:
- Same selected query always returns the same block regardless of the first frame.
- The differing blocks from the paused direct sweep were caused by longer sequence/timing effects rather than a two-frame selector.
Test CS1: Known Generic 00 Page
This rechecks the current generic-primer page for the commands that had different-looking responses in the paused direct sweep.
python scripts/serial_primer_candidate_sweep.py --port COM5 --primer-command 0x00 --candidates "0xA0 0xB8 0xBC" --prompt-power-cycle --log captures/rcp-context-selector-00-a0-b8-bc.txt
Expected from prior primer sweeps:
| Pair | Expected response |
|---|---|
00 -> A0 |
07 80 68 40 30 C5 |
00 -> B8 |
07 80 EE 40 30 43 |
00 -> BC |
07 80 EF 40 30 42 |
Test CS2: Suspected Alternate Selectors
These test the pairings implied by the paused direct sweep. Power-cycle before each prompt.
python scripts/serial_primer_candidate_sweep.py --port COM5 --primer-command 0x9F --candidates 0xA0 --prompt-power-cycle --log captures/rcp-context-selector-9f-a0.txt
python scripts/serial_primer_candidate_sweep.py --port COM5 --primer-command 0xB7 --candidates 0xB8 --prompt-power-cycle --log captures/rcp-context-selector-b7-b8.txt
python scripts/serial_primer_candidate_sweep.py --port COM5 --primer-command 0xBB --candidates 0xBC --prompt-power-cycle --log captures/rcp-context-selector-bb-bc.txt
python scripts/serial_primer_candidate_sweep.py --port COM5 --primer-command 0xAF --candidates 0xB0 --prompt-power-cycle --log captures/rcp-context-selector-af-b0.txt
Compare against these paused/direct observations:
| Pair under test | Context hypothesis if reproduced |
|---|---|
9F -> A0 |
A0 may return 07 80 E8 40 30 45 after selector 9F. |
B7 -> B8 |
B8 may return 07 80 6E 40 30 C3 after selector B7. |
BB -> BC |
BC may return 07 80 6F 40 30 C2 after selector BB. |
AF -> B0 |
B0 may return 07 80 6C 60 30 E1 after selector AF. |
Test CS3: Check for Three-Frame Context
The paused sweep's A0 response happened after 90 and 9F had both been
sent in the same powered session. If 9F -> A0 does not reproduce the alternate
A0 block, try the full three-frame setup:
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0x90 0x9F 0xA0" --states 0x00 --values 0x80 --settle 3 --after-each 0.8 --after 3 --log captures/rcp-context-seq-90-9f-a0.txt
Power-cycle once before this test and do not power-cycle until the script exits.
Interpretation:
- If
9F -> A0reproduces07 80 E8 40 30 45, a two-frame selector is likely. - If only
90 -> 9F -> A0reproduces it, the context/page setup may require multiple host frames. - If neither reproduces it, treat the paused direct
A0response as a sequence/timing artifact until another capture confirms it.
Optional Single-Frame Controls
These check whether the candidate can respond as the first frame after boot.
python scripts/serial_direct_response_sweep.py --port COM5 --commands 0xA0 --states 0x00 --values 0x80 --settle 3 --after-each 1.5 --after 2 --log captures/rcp-context-single-a0.txt
python scripts/serial_direct_response_sweep.py --port COM5 --commands 0xB8 --states 0x00 --values 0x80 --settle 3 --after-each 1.5 --after 2 --log captures/rcp-context-single-b8.txt
python scripts/serial_direct_response_sweep.py --port COM5 --commands 0xBC --states 0x00 --values 0x80 --settle 3 --after-each 1.5 --after 2 --log captures/rcp-context-single-bc.txt
Power-cycle before each single-frame control.
2026-05-13 Context Selector Dataset Results
New captures:
captures/rcp-context-selector-00-a0-b8-bc.txtcaptures/rcp-context-selector-9f-a0.txtcaptures/rcp-context-selector-b7-b8.txtcaptures/rcp-context-selector-bb-bc.txtcaptures/rcp-context-selector-af-b0.txtcaptures/rcp-context-seq-90-9f-a0.txtcaptures/rcp-context-single-a0.txtcaptures/rcp-context-single-b8.txtcaptures/rcp-context-single-bc.txt
Observed results:
| Test | Sequence | Observed response |
|---|---|---|
| CS1 | 00 -> A0 |
07 80 E8 40 30 45 |
| CS1 | 00 -> B8 |
07 80 6E 40 30 C3 |
| CS1 | 00 -> BC |
07 80 6F 40 30 C2 |
| CS2 | 9F -> A0 |
heartbeat only |
| CS2 | B7 -> B8 |
07 80 6E 40 30 C3 |
| CS2 | BB -> BC |
07 80 6F 40 30 C2 |
| CS2 | AF -> B0 |
07 80 6C 40 30 C1 |
| CS3 | 90 -> 9F -> A0 |
07 80 68 40 30 C5 |
| Single-frame control | A0 |
heartbeat only |
| Single-frame control | B8 |
heartbeat only |
| Single-frame control | BC |
heartbeat only |
Important comparison against earlier sweeps:
| Selected query | Earlier primer sweep response | New 00 -> query response |
|---|---|---|
A0 |
07 80 68 40 30 C5 |
07 80 E8 40 30 45 |
B8 |
07 80 EE 40 30 43 |
07 80 6E 40 30 C3 |
BC |
07 80 EF 40 30 42 |
07 80 6F 40 30 C2 |
Interpretation:
- Single
A0,B8, andBCframes after boot produced heartbeat only, so these responses require prior host traffic. - The response is not determined only by the selected query command. The same selected query can produce different response blocks in different setup contexts.
B7 -> B8andBB -> BCreproduced the alternateB8/BCresponses seen in the paused direct sweep.90 -> 9F -> A0reproduced the earlierA0response07 80 68 40 30 C5, while9F -> A0alone produced no response.00 -> A0now produced the alternateA0response07 80 E8 40 30 45, so the00first frame is not always a simple deterministic "generic primer" in the current bench state.- The evidence now favors a stateful/page-sensitive discovery model rather than a single fixed primer model.
Working model after these datasets:
Host sends one or more setup/selector frames.
RCP arms one readable response.
The next selected query returns a block from the currently selected page/state.
After that response, the RCP latches until power cycle or an unknown reset/state
advance command.
Recommended next confirmation:
- Repeat
00 -> A0,00 -> B8, and00 -> BConce more after clean power cycles to see whether the alternate page is now stable. - Repeat
90 -> 9F -> A0once more to confirm the earlier page can be selected reliably. - Test whether
90 -> A0alone selects the earlier page, or whether9Fis also required. - Test whether
00 -> 9F -> A0behaves like90 -> 9F -> A0, which would suggest9Fis the real selector and90is only a setup/arming frame.
Suggested commands:
python scripts/serial_primer_candidate_sweep.py --port COM5 --primer-command 0x00 --candidates "0xA0 0xB8 0xBC" --prompt-power-cycle --log captures/rcp-context-repeat-00-a0-b8-bc.txt
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0x90 0x9F 0xA0" --states 0x00 --values 0x80 --settle 3 --after-each 0.8 --after 3 --log captures/rcp-context-repeat-90-9f-a0.txt
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0x90 0xA0" --states 0x00 --values 0x80 --settle 3 --after-each 0.8 --after 3 --log captures/rcp-context-seq-90-a0.txt
python scripts/serial_direct_response_sweep.py --port COM5 --commands "0x00 0x9F 0xA0" --states 0x00 --values 0x80 --settle 3 --after-each 0.8 --after 3 --log captures/rcp-context-seq-00-9f-a0.txt
2026-05-13 Context Confirmation Result
New captures:
captures/rcp-context-repeat-00-a0-b8-bc.txtcaptures/rcp-context-repeat-90-9f-a0.txtcaptures/rcp-context-seq-90-a0.txtcaptures/rcp-context-seq-00-9f-a0.txt
Observed results:
| Test | Sequence | Observed response |
|---|---|---|
Repeat 00 page |
00 -> A0 |
07 80 68 40 30 C5 |
Repeat 00 page |
00 -> B8 |
07 80 6E 40 30 C3 |
Repeat 00 page |
00 -> BC |
07 80 6F 40 30 C2 |
| Repeat three-frame A0 | 90 -> 9F -> A0 |
07 80 68 40 30 C5 |
A0 with 90 only |
90 -> A0 |
07 80 68 40 30 C5 |
A0 with 00 then 9F |
00 -> 9F -> A0 |
07 80 68 40 30 C5 |
Updated interpretation:
90 -> A0is enough to produce theA0response07 80 68 40 30 C5;9Fis not required for that page.00 -> 9F -> A0also produces07 80 68 40 30 C5, so a frame before9Fcan arm the response, but9Fdoes not appear to select the alternateA0response by itself.- The repeat
00 -> A0result returned to07 80 68 40 30 C5, while the previous00 -> A0context dataset returned07 80 E8 40 30 45. Treat theE8response as real but not yet deterministic from the current two-frame model. 00 -> B8and00 -> BCremained stable as07 80 6E 40 30 C3and07 80 6F 40 30 C2, matching the earlier alternate-page observations.
Current best model:
The RCP requires at least one setup frame before many query commands respond.
Some setup/query pairs are stable, for example 90 -> A0 and 00 -> B8.
Some response differences are still not explained by only the immediately
preceding frame, so a hidden boot/session/state bit or timing-sensitive page
selection may also be involved.
Next useful tests:
- Retest
00 -> A0several times in a row with a power cycle before each run to measure whether68orE8is the dominant response. - Try direct pairs for the observed alternate
B8/BCfamily:B8 -> B9,BC -> BD, andBD -> BE. - Sweep the
D0-DFregion with the same primer-pair method to see whether the structured discovery table continues afterCF.
Unlatch / State-Advance Sweep
Goal: intentionally put the RCP into the known one-response latched state, send a wide set of possible reset/ack/state-advance commands, then verify whether a known query can respond again without a power cycle.
Use scripts/serial_unlatch_sweep.py. For each candidate it performs:
latch primer -> latch query -> candidate unlatch command -> verify primer -> verify query
Default latch and verify sequence:
00 -> B5 produces known response: 07 80 6D 20 D8 48
candidate possible unlatch / state advance command
00 -> B5 verify whether the known response can happen again
Interpretation:
- If the verify query returns heartbeat only, the candidate did not unlatch the one-response state.
- If the verify query returns
07 80 6D 20 D8 48again, the candidate likely cleared or advanced the latch. - If the candidate itself changes the LCD or produces a new serial response, log it as a possible state-advance command even if the verify query does not respond.
First wide assortment, focused on known response command families, boundaries, and current no-response gaps:
python scripts/serial_unlatch_sweep.py --port COM5 --candidates "0x00 0x01 0x03 0x07 0x0A 0x0C 0x0D 0x0E 0x0F 0x10 0x1A 0x1B 0x1C 0x20 0x30 0x36 0x38 0x39 0x40 0x4F 0x50 0x5B 0x68 0x6C 0x6D 0x6E 0x6F 0x70 0x7F 0x80 0x8F 0x90 0x9F 0xA0 0xAF 0xB0 0xB5 0xB8 0xBC 0xBE 0xBF 0xC0 0xCF 0xD0 0xDF 0xE0 0xEF 0xF0 0xFF" --expected-verify-response "07 80 6D 20 D8 48" --prompt-power-cycle --prompt-screen --log captures/rcp-unlatch-wide-after-b5.txt
Power-cycle before each prompt. For the screen prompt:
- Press Enter if the screen stayed the same.
- Type the exact screen text if it changes.
- Type
qto stop.
If this finds no verify responses, try the same idea after a different latch query page:
python scripts/serial_unlatch_sweep.py --port COM5 --latch-query-command 0xA0 --verify-query-command 0xA0 --candidates "0x00 0x01 0x0F 0x10 0x1A 0x1B 0x40 0x4F 0x68 0x6C 0x80 0x8F 0x90 0x9F 0xA0 0xB0 0xB8 0xBC 0xC0 0xCF 0xE0 0xEF 0xFF" --expected-verify-response "07 80 68 40 30 C5" --prompt-power-cycle --prompt-screen --log captures/rcp-unlatch-wide-after-a0.txt
For a fast dry run without touching the serial port:
python scripts/serial_unlatch_sweep.py --port COM5 --candidates "0x00 0x01 0x90" --dry-run
2026-05-13 Unlatch Sweep Result
Captures:
captures/rcp-unlatch-wide-after-b5.txtcaptures/rcp-unlatch-wide-after-a0.txt
User observation:
- No visible RCP state change was seen during the tests.
- The only screen note recorded in the logs was
CONNECT NOT ACTafter candidate0x00, which matches the already-known non-active connected state.
Serial result:
| Latch/verify query | Candidates tested | Expected verify response | Result |
|---|---|---|---|
B5 |
49 | 07 80 6D 20 D8 48 |
no confirmed unlatch |
A0 |
23 | 07 80 68 40 30 C5 |
no confirmed unlatch |
Notes:
- Candidate
0xBFin theB5unlatch sweep produced a verify-query anomaly, but the raw bytes were00 00 00 00 00 00 80 DA, not the expected07 80 6D 20 D8 48. Treat this as a heartbeat/chunking/classifier artifact, not a successful unlatch. - No candidate-stage serial response clearly indicated a state advance.
- The broad command-byte assortment did not find a reset/ack/unlatch command in the tested six-byte frame shape.
Tooling update:
scripts/serial_unlatch_sweep.pynow accepts--expected-verify-response.- Future unlatch sweeps should use this option so only the desired repeated query response counts as a hit.
PT2/PT7 Compatibility Clue
Manual-derived note from a newer Sony RCP:
- A newer Sony RCP has a mode switch with
PT2andPT7positions. PT2is documented for controlling the same camera line that the RCP-TX7 is associated with.
Working implication:
- The TX7 may be a fixed/PT2-era protocol personality rather than a generic Sony RCP protocol endpoint.
- If the CCU/RCP protocol family later split into PT2 and PT7 modes, then our current frame shape may be electrically correct but still missing a personality/mode/session assumption.
- The command bytes that look like "page selectors" may be table reads within the PT2 personality rather than an activation handshake.
Next direction from this clue:
- Treat PT2 compatibility as the default target for TX7 restoration tests.
- Search newer-RCP manuals for whether PT2/PT7 is only a physical switch or whether either mode has visible initialization, connect, or model-detect behavior.
- Prefer tests that emulate a CCU already speaking the TX7/PT2 personality, rather than trying PT7-style/high-range activation guesses.
Button Behavior While Latched
Open questions:
- Does the one-response latched state suppress the RCP-origin button frames that are known to appear while disconnected?
- If the RCP sends
CAM POWER, does an immediate host-side response using the same or a similar command shape change the RCP state?
Known RCP-origin button frames:
| Button/action | RCP frame |
|---|---|
| Idle heartbeat | 00 00 00 00 80 DA |
CAM POWER |
00 00 07 80 00 DD |
CALL on/state high |
00 00 15 80 00 CF |
CALL off/state low |
00 00 15 00 00 4F |
Use scripts/serial_button_response_test.py for these tests. It keeps RX and
TX in the same serial session, so it works around Windows COM-port exclusivity.
Test BTN1: Offline Button Control
Purpose: establish a fresh control capture where the RCP is not intentionally
latched. During the listen window, press CAM POWER a few times and press/release
CALL.
python scripts/serial_button_response_test.py --port COM5 --duration 30 --prompt --log captures/rcp-buttons-offline-control.txt
Expected:
CAM POWERshould produce00 00 07 80 00 DD.CALLshould produce one or both00 00 15 80 00 CFand00 00 15 00 00 4F.
Test BTN2: Latched Button Emission
Purpose: put the RCP into the known 00 -> B5 latched state, then see whether
CAM POWER and CALL still produce RCP-origin frames. During the listen
window, press the same buttons as BTN1.
python scripts/serial_button_response_test.py --port COM5 --latch --latch-query-command 0xB5 --duration 30 --prompt --log captures/rcp-buttons-latched-after-b5.txt
Interpretation:
- If
CAM POWER/CALLframes still appear, the latch suppresses selected query responses but does not suppress basic panel-origin button events. - If button frames disappear, the latch may be closer to a protocol/session hold state that blocks some panel event transmission.
Test BTN3: Respond to CAM POWER With Exact Echo
Purpose: when the RCP sends the CAM POWER frame, immediately send the same
six-byte frame back on the host-to-RCP line. Watch the screen for any visible
change.
python scripts/serial_button_response_test.py --port COM5 --duration 30 --prompt --respond-to-cam-power --respond-once --response-frame "00 00 07 80 00 DD" --log captures/rcp-buttons-cam-power-exact-echo.txt
At the prompt, press CAM POWER once. If the screen changes, note the exact
display text after the run.
Test BTN4: Respond to CAM POWER With Host-Shaped Variant
Purpose: test a related command-shaped host frame where command 0x07 is kept
but the 0x80 bit is in the value field, matching the host-query shape used in
many discovery tests.
python scripts/serial_button_response_test.py --port COM5 --duration 30 --prompt --respond-to-cam-power --respond-once --response-frame "00 00 07 00 80 DD" --log captures/rcp-buttons-cam-power-host-shaped.txt
Interpretation:
- If exact echo changes nothing but the host-shaped variant changes the screen or serial stream, the RCP may expect host responses in the same command class but with host-side state/value layout.
- If neither changes anything,
CAM POWERmay be an outbound event requiring a larger CCU state/session response rather than a direct ACK.
Optional latched version of BTN3:
python scripts/serial_button_response_test.py --port COM5 --latch --latch-query-command 0xB5 --duration 30 --prompt --respond-to-cam-power --respond-once --response-frame "00 00 07 80 00 DD" --log captures/rcp-buttons-latched-cam-power-exact-echo.txt
2026-05-13 Button Test Result
Captures:
captures/rcp-buttons-offline-control.txtcaptures/rcp-buttons-latched-after-b5.txtcaptures/rcp-buttons-cam-power-exact-echo.txtcaptures/rcp-buttons-cam-power-host-shaped.txt
Offline control:
CALLproduced00 00 15 80 00 CFand00 00 15 00 00 4F.CAM POWERproduced00 00 07 80 00 DD.- This matches the original offline button observations.
Latched after 00 -> B5:
- The latch setup produced the known
B5response07 80 6D 20 D8 48. - While in this state,
CALLstill produced both known call frames. - While in this state,
CAM POWERstill produced00 00 07 80 00 DD.
Interpretation:
- The one-response latch suppresses additional selected-query responses, but it does not suppress basic RCP-origin button/event frames.
- The panel is still actively reporting front-panel events after the discovery response/latch state.
CAM POWER response tests:
| Test | Host response sent after CAM POWER |
Screen result | Serial result |
|---|---|---|---|
| BTN3 exact echo | 00 00 07 80 00 DD |
CONNECT NOT ACT |
heartbeat/button-event only |
| BTN4 host-shaped | 00 00 07 00 80 DD |
CONNECT NOT ACT |
heartbeat only after response |
Interpretation:
- Both
CAM POWERresponse shapes are recognized enough to produce the familiarCONNECT NOT ACTdisplay state. - Neither response advanced the RCP into an active state or caused a new serial status stream.
CAM POWERis likely an outbound event that requires broader CCU/session context, not a simple one-frame ACK.
Next useful button-side tests:
- Repeat BTN3/BTN4 while already latched after
00 -> B5; this checks whether the sameCAM POWERresponse has different meaning after the RCP has already returned a discovery block. - Try responding to
CALLwith exact echo and host-shaped command0x15variants, since earlier0x15matrix tests changed the screen but did not activate the panel. - If a future session/keepalive candidate is found, rerun BTN1/BTN2 to see whether more front-panel controls begin emitting serial events in an active context.
CALL Echo / Response Tests
Goal: test whether the RCP treats CALL differently from CAM POWER when the
host immediately echoes or acknowledges the outbound button event.
Known RCP-origin CALL frames:
CALL high/on: 00 00 15 80 00 CF
CALL low/off: 00 00 15 00 00 4F
Test BTN5: exact echo of both known CALL shapes.
python scripts/serial_button_response_test.py --port COM5 --duration 30 --prompt --respond-to-call --respond-once --response-frame "00 00 15 80 00 CF" --response-frame "00 00 15 00 00 4F" --log captures/rcp-buttons-call-exact-echo.txt
Test BTN6: host-shaped CALL response, with command 0x15 and value 0x80.
python scripts/serial_button_response_test.py --port COM5 --duration 30 --prompt --respond-to-call --respond-once --response-frame "00 00 15 00 80 CF" --log captures/rcp-buttons-call-host-shaped.txt
Test BTN7: host-shaped CALL response after the known 00 -> B5 latch.
python scripts/serial_button_response_test.py --port COM5 --latch --latch-query-command 0xB5 --duration 30 --prompt --respond-to-call --respond-once --response-frame "00 00 15 00 80 CF" --log captures/rcp-buttons-latched-call-host-shaped.txt
During each test, press and release CALL once or twice. Record any screen
change after the run.
2026-05-13 CALL Echo Result
Captures:
captures/rcp-buttons-call-exact-echo.txtcaptures/rcp-buttons-call-host-shaped.txtcaptures/rcp-buttons-latched-call-host-shaped.txt
User observation:
- All three CALL response tests ended with the RCP screen at
CONNECT NOT ACT.
Serial result:
| Test | Host response after CALL |
Serial result |
|---|---|---|
| BTN5 exact echo | 00 00 15 80 00 CF then 00 00 15 00 00 4F |
RCP sent 07 80 45 20 D0 68 once, then returned to heartbeat/CALL events |
| BTN6 host-shaped | 00 00 15 00 80 CF |
heartbeat/CALL events only |
| BTN7 latched host-shaped | 00 00 15 00 80 CF after latch setup |
heartbeat/CALL events only |
Interpretation:
- Exact CALL echo is more interesting than CAM POWER echo: it produced a new
checksum-valid RCP response frame,
07 80 45 20 D0 68. - The new frame did not visibly activate the RCP; the panel still ended at
CONNECT NOT ACT. - The host-shaped
CALLresponse did not reproduce the new frame, either offline or after theB5latch setup. - This suggests the RCP has at least one event-response path for CALL exact echo, but that response is still not the missing active-session handshake.
Next CALL-focused checks:
- Retest exact CALL echo three times with clean power cycles to see whether
07 80 45 20 D0 68is repeatable. - Test echoing only
CALL high/onand onlyCALL low/offseparately to see which of the two echoed frames causes07 80 45 20 D0 68. - Try using
07 80 45 20 D0 68as a follow-up host frame after CALL exact echo, only after confirming repeatability.
Real-World CALL Hold/Release Test
Goal: mimic how CALL would likely work in use:
User holds CALL -> RCP sends CALL high/on
Host responds high -> host echoes/acknowledges CALL high/on
User releases CALL -> RCP sends CALL low/off
Host responds low -> host echoes/acknowledges CALL low/off
Test BTN8: mirror CALL high and low once per state.
python scripts/serial_button_response_test.py --port COM5 --duration 30 --prompt --mirror-call --mirror-call-once-per-state --log captures/rcp-buttons-call-mirror-hold-release.txt
Procedure:
- Power-cycle the RCP.
- Start the command and press Enter at the prompt.
- Hold
CALLfor about 2 seconds. - Release
CALL. - Watch whether the screen changes and note the final screen text.
Interpretation:
- If the RCP again sends
07 80 45 20 D0 68, the frame is likely part of the CALL response path. - If the screen still ends at
CONNECT NOT ACT, this mirrors CALL signaling but still does not satisfy the active-session handshake.
Optional latched version:
python scripts/serial_button_response_test.py --port COM5 --latch --latch-query-command 0xB5 --duration 30 --prompt --mirror-call --mirror-call-once-per-state --log captures/rcp-buttons-latched-call-mirror-hold-release.txt
2026-05-13 Latched CALL Mirror Result
Capture:
captures/rcp-buttons-latched-call-mirror-hold-release.txt
The capture contains three appended latched runs. Each run sent the 00 -> B5
latch setup, then mirrored observed CALL high/low events with the matching CALL
frame.
Observed result:
- The RCP still emitted CALL high/low frames while latched.
- The mirror script sent
CALL high mirrorand/orCALL low mirrorresponses as expected. - No run reproduced the earlier exact-echo response
07 80 45 20 D0 68. - Serial output returned to heartbeat/CALL event traffic.
Interpretation:
- The earlier
07 80 45 20 D0 68response appears tied to sending both CALL echo frames immediately after CALL high, not to a realistic held/released CALL mirror sequence. - Mirroring CALL state while latched does not appear to activate or unlatch the RCP.
- The latched state continues to allow front-panel CALL events to be transmitted.
Tooling note:
scripts/serial_button_response_test.pynow clears the serial input buffer immediately after the manual prompt. This avoids stale frames collected while waiting at the prompt contaminating button timing in future hold/release tests.
Clean non-latched repeat, if needed:
python scripts/serial_button_response_test.py --port COM5 --duration 30 --prompt --mirror-call --mirror-call-once-per-state --log captures/rcp-buttons-call-mirror-hold-release.txt
CALL Exact-Echo Reproducibility Test
Goal: determine whether the new frame 07 80 45 20 D0 68 is reproducible when
using the artificial exact-CALL echo that originally produced it.
Test BTN9: repeat exact CALL echo and explicitly watch for 07 80 45 20 D0 68.
python scripts/serial_button_response_test.py --port COM5 --duration 15 --prompt --respond-to-call --respond-once --response-frame "00 00 15 80 00 CF" --response-frame "00 00 15 00 00 4F" --watch-frame "07 80 45 20 D0 68" --log captures/rcp-buttons-call-exact-echo-repro-1.txt
Run the same command three times, changing only the log filename:
python scripts/serial_button_response_test.py --port COM5 --duration 15 --prompt --respond-to-call --respond-once --response-frame "00 00 15 80 00 CF" --response-frame "00 00 15 00 00 4F" --watch-frame "07 80 45 20 D0 68" --log captures/rcp-buttons-call-exact-echo-repro-2.txt
python scripts/serial_button_response_test.py --port COM5 --duration 15 --prompt --respond-to-call --respond-once --response-frame "00 00 15 80 00 CF" --response-frame "00 00 15 00 00 4F" --watch-frame "07 80 45 20 D0 68" --log captures/rcp-buttons-call-exact-echo-repro-3.txt
Procedure for each run:
- Power-cycle the RCP.
- Start the command and press Enter at the prompt.
- Press
CALLonce. - Stop after the script exits, then power-cycle before the next run.
Interpretation:
- If
Watch totals: 07 80 45 20 D0 68=1appears consistently, the frame is a reproducible response to artificial exact CALL echo. - If it appears intermittently, timing or current panel state is probably part of the trigger.
- If it does not appear, the original hit may have depended on a very specific press/release timing or buffered frame ordering.
2026-05-13 CALL Exact-Echo Repro Result
Captures:
captures/rcp-buttons-call-exact-echo-repro-1.txtcaptures/rcp-buttons-call-exact-echo-repro-2.txtcaptures/rcp-buttons-call-exact-echo-repro-3.txt
All three runs detected CALL high/on and sent the same exact echo pair:
00 00 15 80 00 CF
00 00 15 00 00 4F
Observed serial result:
| Run | Result |
|---|---|
| repro 1 | random assortment of button presses; no 07 80 45 20 D0 68; returned to heartbeat/CALL traffic |
| repro 2 | press-and-hold CALL; 07 80 45 20 D0 68 observed once, about 33 ms after the echo pair |
| repro 3 | quick CALL press only; no 07 80 45 20 D0 68; returned to heartbeat traffic |
Interpretation:
- The
07 80 45 20 D0 68frame is reproducible, but appears sensitive to physical CALL timing. It has now been seen in the original exact-echo test and in the press-and-hold repro run. - Because each run sent the same two response frames after
CALLhigh, the strongest current hypothesis is that CALL must remain asserted briefly after the host echo pair. - Receive buffer alignment or an internal RCP state bit may still be involved, but the quick-press miss and press-and-hold hit make button hold duration the next variable to isolate.
- This frame is still best treated as a CALL/event-response clue, not as an activation handshake.
Next tighter CALL tests:
- Echo only
CALL high/on. - Echo only
CALL low/off. - Repeat the two-frame exact echo while deliberately holding CALL until the script has logged either the watch frame or the next heartbeat.
- Repeat the two-frame exact echo with shorter and longer response delays.
High-only echo:
python scripts/serial_button_response_test.py --port COM5 --duration 15 --prompt --respond-to-call --respond-once --response-frame "00 00 15 80 00 CF" --watch-frame "07 80 45 20 D0 68" --log captures/rcp-buttons-call-high-only-echo.txt
Low-only echo:
python scripts/serial_button_response_test.py --port COM5 --duration 15 --prompt --respond-to-call --respond-once --response-frame "00 00 15 00 00 4F" --watch-frame "07 80 45 20 D0 68" --log captures/rcp-buttons-call-low-only-echo.txt
Two-frame echo with a shorter response delay:
python scripts/serial_button_response_test.py --port COM5 --duration 15 --prompt --respond-to-call --respond-once --response-delay 0.0 --response-frame "00 00 15 80 00 CF" --response-frame "00 00 15 00 00 4F" --watch-frame "07 80 45 20 D0 68" --log captures/rcp-buttons-call-exact-echo-delay-0ms.txt
Two-frame echo with a longer response delay:
python scripts/serial_button_response_test.py --port COM5 --duration 15 --prompt --respond-to-call --respond-once --response-delay 0.2 --response-frame "00 00 15 80 00 CF" --response-frame "00 00 15 00 00 4F" --watch-frame "07 80 45 20 D0 68" --log captures/rcp-buttons-call-exact-echo-delay-200ms.txt
2026-05-13 CALL Hold Timing Tests
Captures:
captures/rcp-buttons-call-high-only-echo.txtcaptures/rcp-buttons-call-low-only-echo.txtcaptures/rcp-buttons-call-exact-echo-delay-0ms.txtcaptures/rcp-buttons-call-exact-echo-delay-200ms.txt
User procedure:
- All four tests used a roughly 2 second hold on the
CALLbutton.
Observed result:
| Test | Host response | Result |
|---|---|---|
| high-only echo | 00 00 15 80 00 CF after CALL high |
no 07 80 45 20 D0 68 |
| low-only echo | 00 00 15 00 00 4F after CALL high |
no 07 80 45 20 D0 68 |
| exact echo, 0 ms delay | high echo then low echo immediately | no 07 80 45 20 D0 68 |
| exact echo, 200 ms delay | high echo then low echo after 200 ms response delay | no 07 80 45 20 D0 68 |
Interpretation:
- Holding
CALLalone is not sufficient to reproduce07 80 45 20 D0 68. - Echoing only one of the two CALL states is not sufficient in these tests.
- The previous successful repro used the two-frame exact echo with the script's default 50 ms response delay. The failed 0 ms and 200 ms runs suggest the timing window may be narrower than expected, or the frame depends on a second uncontrolled variable.
- Current best hypothesis:
07 80 45 20 D0 68requires the exact two-frame CALL echo pair near the default delay timing, with CALL still asserted.
Next timing-bracket test:
python scripts/serial_button_response_test.py --port COM5 --duration 15 --prompt --respond-to-call --respond-once --response-delay 0.02 --response-frame "00 00 15 80 00 CF" --response-frame "00 00 15 00 00 4F" --watch-frame "07 80 45 20 D0 68" --log captures/rcp-buttons-call-exact-echo-delay-20ms.txt
python scripts/serial_button_response_test.py --port COM5 --duration 15 --prompt --respond-to-call --respond-once --response-delay 0.05 --response-frame "00 00 15 80 00 CF" --response-frame "00 00 15 00 00 4F" --watch-frame "07 80 45 20 D0 68" --log captures/rcp-buttons-call-exact-echo-delay-50ms.txt
python scripts/serial_button_response_test.py --port COM5 --duration 15 --prompt --respond-to-call --respond-once --response-delay 0.08 --response-frame "00 00 15 80 00 CF" --response-frame "00 00 15 00 00 4F" --watch-frame "07 80 45 20 D0 68" --log captures/rcp-buttons-call-exact-echo-delay-80ms.txt
python scripts/serial_button_response_test.py --port COM5 --duration 15 --prompt --respond-to-call --respond-once --response-delay 0.12 --response-frame "00 00 15 80 00 CF" --response-frame "00 00 15 00 00 4F" --watch-frame "07 80 45 20 D0 68" --log captures/rcp-buttons-call-exact-echo-delay-120ms.txt
For each run, power-cycle first, press and hold CALL for about 2 seconds, then
release after either the watch frame appears or the next heartbeat appears.
2026-05-13 CALL Timing-Bracket Result
Captures:
captures/rcp-buttons-call-exact-echo-delay-20ms.txtcaptures/rcp-buttons-call-exact-echo-delay-50ms.txtcaptures/rcp-buttons-call-exact-echo-delay-80ms.txtcaptures/rcp-buttons-call-exact-echo-delay-120ms.txt
User procedure:
- Each run used the same two-frame exact CALL echo pair.
- Button hold timing was kept as accurate and consistent as possible.
Observed result:
| Delay | Result |
|---|---|
| 20 ms | heartbeat only; no 0x45 response |
| 50 ms | heartbeat/CALL traffic only; no 0x45 response |
| 80 ms | new response 07 80 45 30 D0 78 |
| 120 ms | heartbeat/CALL traffic only; no 0x45 response |
Comparison of known CALL-response-family frames:
07 80 45 20 D0 68
07 80 45 30 D0 78
Both frames are checksum-valid under the current XOR-with-0x5A hypothesis.
They share prefix 07 80, command/status byte 45, and value byte D0. The
state/status byte changed from 20 to 30, with the checksum changing from
68 to 78 as expected.
Interpretation:
- The RCP appears to have a CALL-related
0x45response family. - The observed
0x45response is timing-sensitive but not locked only to the original 50 ms response delay. - The
0x20vs0x30byte may represent a CALL/button substate, link/session substate, or timing/window state. - This is stronger evidence that the panel is responding meaningfully to host traffic, even though the LCD state still has not been driven active.
Next CALL timing tests should watch both known 0x45 family frames:
python scripts/serial_button_response_test.py --port COM5 --duration 15 --prompt --respond-to-call --respond-once --response-delay 0.06 --response-frame "00 00 15 80 00 CF" --response-frame "00 00 15 00 00 4F" --watch-frame "07 80 45 20 D0 68" --watch-frame "07 80 45 30 D0 78" --log captures/rcp-buttons-call-exact-echo-delay-60ms.txt
python scripts/serial_button_response_test.py --port COM5 --duration 15 --prompt --respond-to-call --respond-once --response-delay 0.07 --response-frame "00 00 15 80 00 CF" --response-frame "00 00 15 00 00 4F" --watch-frame "07 80 45 20 D0 68" --watch-frame "07 80 45 30 D0 78" --log captures/rcp-buttons-call-exact-echo-delay-70ms.txt
python scripts/serial_button_response_test.py --port COM5 --duration 15 --prompt --respond-to-call --respond-once --response-delay 0.08 --response-frame "00 00 15 80 00 CF" --response-frame "00 00 15 00 00 4F" --watch-frame "07 80 45 20 D0 68" --watch-frame "07 80 45 30 D0 78" --log captures/rcp-buttons-call-exact-echo-delay-80ms-v2.txt
python scripts/serial_button_response_test.py --port COM5 --duration 15 --prompt --respond-to-call --respond-once --response-delay 0.09 --response-frame "00 00 15 80 00 CF" --response-frame "00 00 15 00 00 4F" --watch-frame "07 80 45 20 D0 68" --watch-frame "07 80 45 30 D0 78" --log captures/rcp-buttons-call-exact-echo-delay-90ms.txt
python scripts/serial_button_response_test.py --port COM5 --duration 15 --prompt --respond-to-call --respond-once --response-delay 0.10 --response-frame "00 00 15 80 00 CF" --response-frame "00 00 15 00 00 4F" --watch-frame "07 80 45 20 D0 68" --watch-frame "07 80 45 30 D0 78" --log captures/rcp-buttons-call-exact-echo-delay-100ms.txt
If the 0x45 family repeats in the 60-100 ms window, the next step is to test
whether the host can answer the RCP's 0x45 response with a checksum-valid
host-shaped frame using command byte 0x45.
Tooling note:
scripts/serial_button_response_test.pynow supports--followup-on-watch-framewith one or more--followup-framevalues. This lets the host answer a reproduced RCP response immediately in the same run.
Possible follow-up test after reproducing a 0x45 response:
python scripts/serial_button_response_test.py --port COM5 --duration 15 --prompt --respond-to-call --respond-once --response-delay 0.08 --response-frame "00 00 15 80 00 CF" --response-frame "00 00 15 00 00 4F" --watch-frame "07 80 45 20 D0 68" --watch-frame "07 80 45 30 D0 78" --followup-on-watch-frame --followup-frame "00 00 45 00 80 9F" --log captures/rcp-buttons-call-45-followup-host-shaped.txt
This test is deliberately secondary. Run it only after the 0x45 family
repeats, so any change can be attributed to the follow-up rather than to the
initial CALL echo timing.
2026-05-13 CALL 60-100 ms Repeat Result
Captures:
captures/rcp-buttons-call-exact-echo-delay-60ms.txtcaptures/rcp-buttons-call-exact-echo-delay-70ms.txtcaptures/rcp-buttons-call-exact-echo-delay-80ms-v2.txtcaptures/rcp-buttons-call-exact-echo-delay-90ms.txtcaptures/rcp-buttons-call-exact-echo-delay-100ms.txt
Observed result:
| Delay | Result |
|---|---|
| 60 ms | no 0x45 response |
| 70 ms | no 0x45 response |
| 80 ms repeat | no 0x45 response |
| 90 ms | no 0x45 response |
| 100 ms | no 0x45 response |
Interpretation:
- The
07 80 45 30 D0 78response from the earlier 80 ms run did not repeat in the 80 ms repeat or nearby 60-100 ms bracket. - The trigger is not controlled by the simple delay between CALL high detection and the two-frame echo pair alone.
- A more likely variable is the spacing between the host's CALL-high echo and CALL-low echo, or the RCP's internal heartbeat/call-scan phase when the echo pair arrives.
Next test direction:
- Keep the initial response delay fixed near the values that have produced hits before, but vary the spacing between the two echoed CALL frames.
Tooling note:
scripts/serial_button_response_test.pynow supports--response-frame-interval, which inserts a delay between multiple--response-framevalues sent for the same observed button event.
Inter-frame timing ladder:
python scripts/serial_button_response_test.py --port COM5 --duration 15 --prompt --respond-to-call --respond-once --response-delay 0.05 --response-frame-interval 0.02 --response-frame "00 00 15 80 00 CF" --response-frame "00 00 15 00 00 4F" --watch-frame "07 80 45 20 D0 68" --watch-frame "07 80 45 30 D0 78" --log captures/rcp-buttons-call-frame-gap-20ms.txt
python scripts/serial_button_response_test.py --port COM5 --duration 15 --prompt --respond-to-call --respond-once --response-delay 0.05 --response-frame-interval 0.05 --response-frame "00 00 15 80 00 CF" --response-frame "00 00 15 00 00 4F" --watch-frame "07 80 45 20 D0 68" --watch-frame "07 80 45 30 D0 78" --log captures/rcp-buttons-call-frame-gap-50ms.txt
python scripts/serial_button_response_test.py --port COM5 --duration 15 --prompt --respond-to-call --respond-once --response-delay 0.05 --response-frame-interval 0.08 --response-frame "00 00 15 80 00 CF" --response-frame "00 00 15 00 00 4F" --watch-frame "07 80 45 20 D0 68" --watch-frame "07 80 45 30 D0 78" --log captures/rcp-buttons-call-frame-gap-80ms.txt
python scripts/serial_button_response_test.py --port COM5 --duration 15 --prompt --respond-to-call --respond-once --response-delay 0.08 --response-frame-interval 0.05 --response-frame "00 00 15 80 00 CF" --response-frame "00 00 15 00 00 4F" --watch-frame "07 80 45 20 D0 68" --watch-frame "07 80 45 30 D0 78" --log captures/rcp-buttons-call-delay-80ms-frame-gap-50ms.txt
For each run, power-cycle first and use the same roughly 2 second CALL hold.
2026-05-13 CALL Inter-Frame Gap Result
Captures:
captures/rcp-buttons-call-frame-gap-20ms.txtcaptures/rcp-buttons-call-frame-gap-50ms.txtcaptures/rcp-buttons-call-frame-gap-80ms.txtcaptures/rcp-buttons-call-delay-80ms-frame-gap-50ms.txt
Observed result:
| Initial delay | Gap between host CALL echoes | Result |
|---|---|---|
| 50 ms | 20 ms | 07 80 45 20 D0 68 |
| 50 ms | 50 ms | 07 80 45 20 D0 68 |
| 50 ms | 80 ms | 07 80 45 20 D0 68 |
| 80 ms | 50 ms | 07 80 45 20 D0 68 |
Interpretation:
07 80 45 20 D0 68is now reproducible.- The key change was adding a gap between the host's CALL-high echo and CALL-low echo. Earlier tests sent the two response frames back-to-back.
- The exact gap is not especially narrow; 20 ms, 50 ms, and 80 ms all worked in this run set.
- The RCP likely needs to process the high echo as one event before receiving the low echo. Sending high and low in one tight burst can land outside that event path.
- The
0x45response is still not known to activate the panel, but it is a real, reproducible event-response path.
Next step: answer the reproducible 0x45 response in the same run.
Test F1: host-shaped generic 0x45 ACK.
python scripts/serial_button_response_test.py --port COM5 --duration 15 --prompt --respond-to-call --respond-once --response-delay 0.05 --response-frame-interval 0.05 --response-frame "00 00 15 80 00 CF" --response-frame "00 00 15 00 00 4F" --watch-frame "07 80 45 20 D0 68" --followup-on-watch-frame --followup-frame "00 00 45 00 80 9F" --log captures/rcp-buttons-call-45-followup-generic-ack.txt
Test F2: host-shaped echo of the RCP 0x45 payload.
python scripts/serial_button_response_test.py --port COM5 --duration 15 --prompt --respond-to-call --respond-once --response-delay 0.05 --response-frame-interval 0.05 --response-frame "00 00 15 80 00 CF" --response-frame "00 00 15 00 00 4F" --watch-frame "07 80 45 20 D0 68" --followup-on-watch-frame --followup-frame "00 00 45 20 D0 EF" --log captures/rcp-buttons-call-45-followup-payload-echo.txt
Test F3: exact echo of the RCP 0x45 response frame.
python scripts/serial_button_response_test.py --port COM5 --duration 15 --prompt --respond-to-call --respond-once --response-delay 0.05 --response-frame-interval 0.05 --response-frame "00 00 15 80 00 CF" --response-frame "00 00 15 00 00 4F" --watch-frame "07 80 45 20 D0 68" --followup-on-watch-frame --followup-frame "07 80 45 20 D0 68" --log captures/rcp-buttons-call-45-followup-exact-echo.txt
For each follow-up test, note whether the LCD changes, whether more serial data appears after the follow-up, and whether the panel returns to heartbeat only.
2026-05-13 CALL 0x45 Follow-Up Result
Captures:
captures/rcp-buttons-call-45-followup-generic-ack.txtcaptures/rcp-buttons-call-45-followup-payload-echo.txtcaptures/rcp-buttons-call-45-followup-exact-echo.txt
Observed result:
| Test | Follow-up sent after 07 80 45 20 D0 68 |
Serial result |
|---|---|---|
| F1 generic ACK | 00 00 45 00 80 9F |
heartbeat only after follow-up |
| F2 payload echo | 00 00 45 20 D0 EF |
heartbeat only after follow-up |
| F3 exact echo | 07 80 45 20 D0 68 |
heartbeat only after follow-up |
Notes:
- F1 and F2 reproduced the normal CALL-high echo path, then sent the follow-up
frame after the RCP emitted
07 80 45 20 D0 68. - F3 still reproduced
07 80 45 20 D0 68, but the triggering CALL event was captured as a split CALL-off frame rather than a clean CALL-on log line. The script's rolling buffer still recognized the frame and sent the configured responses. - None of the three follow-up shapes caused a visible serial-side state change in the captured data. After the follow-up, the RCP returned to heartbeat.
Interpretation:
- The
0x45frame is likely an RCP-origin response/notification in the CALL event path, but these simple host answers are not the missing activation handshake. - The panel may not expect a direct answer to
0x45, or the answer needs more session context than a single command frame. - Since
0x45can be produced from the CALL-off side too, the RCP may be responding to a CALL state transition sequence rather than specifically to CALL high.
Next direction:
- Use the reproducible CALL echo/gap sequence as a diagnostic, but return to
the main activation problem: what host/session traffic makes the RCP leave
CONNECT NOT ACT. - Test whether a known discovery query still works immediately after the CALL
0x45path, and whether CALL0x45changes the one-shot/latch behavior.
CALL then discovery query:
python scripts/serial_button_response_test.py --port COM5 --duration 15 --prompt --respond-to-call --respond-once --response-delay 0.05 --response-frame-interval 0.05 --response-frame "00 00 15 80 00 CF" --response-frame "00 00 15 00 00 4F" --watch-frame "07 80 45 20 D0 68" --followup-on-watch-frame --followup-frame "00 00 00 00 80 DA" --followup-frame "00 00 B5 00 80 6F" --log captures/rcp-buttons-call-45-followup-discovery-b5.txt
If this produces the known B5 response 07 80 6D 20 D8 48, then the CALL
path does not consume the one-shot discovery response. If it returns heartbeat
only, CALL/0x45 may put the RCP into a similar one-shot consumed state.
2026-05-13 CALL 0x45 Then Discovery Result
Capture:
captures/rcp-buttons-call-45-followup-discovery-b5.txt
Observed sequence:
RCP CALL high: 00 00 15 80 00 CF
Host CALL high echo: 00 00 15 80 00 CF
Host CALL low echo: 00 00 15 00 00 4F
RCP CALL response: 07 80 45 20 D0 68
Host primer: 00 00 00 00 80 DA
Host B5 query: 00 00 B5 00 80 6F
Result:
- After the follow-up
00 -> B5query, the RCP returned heartbeat-compatible traffic only. - The known
B5response07 80 6D 20 D8 48did not appear.
Interpretation:
- The CALL/
0x45path does not unlock the known discovery query. - It may consume or bypass the same cold one-shot discovery window, or the RCP may simply ignore discovery-style queries once the CALL event path has been exercised.
- This pushes the CALL path into the "useful diagnostic but probably not the activation handshake" bucket.
Cold No-Button CALL Injection Tests
Question: have we tried sending the CALL response frames without first pressing
the CALL button?
Answer: partially, but not in the exact form that now matters.
- Earlier command
0x15matrix tests sent individual0x15frames from a cold panel and sawCONNECT NOT ACT, but no non-heartbeat serial response. - The newer reproducible
0x45result depends on sending the CALL-high and CALL-low frames as a pair with a gap. That exact cold/no-button pair has not been tested yet.
Tooling note:
scripts/serial_button_response_test.pynow supports--startup-frame. These frames are sent automatically after the listen window begins, without waiting for a physical button event.
Test C1: cold CALL pair, 50 ms gap, no physical button press.
python scripts/serial_button_response_test.py --port COM5 --duration 12 --prompt --startup-delay 1.0 --startup-frame-interval 0.05 --startup-frame "00 00 15 80 00 CF" --startup-frame "00 00 15 00 00 4F" --watch-frame "07 80 45 20 D0 68" --watch-frame "07 80 45 30 D0 78" --log captures/rcp-buttons-cold-call-pair-gap-50ms.txt
Test C2: cold CALL pair, 80 ms gap, no physical button press.
python scripts/serial_button_response_test.py --port COM5 --duration 12 --prompt --startup-delay 1.0 --startup-frame-interval 0.08 --startup-frame "00 00 15 80 00 CF" --startup-frame "00 00 15 00 00 4F" --watch-frame "07 80 45 20 D0 68" --watch-frame "07 80 45 30 D0 78" --log captures/rcp-buttons-cold-call-pair-gap-80ms.txt
Test C3: cold CALL high only, no physical button press.
python scripts/serial_button_response_test.py --port COM5 --duration 12 --prompt --startup-delay 1.0 --startup-frame "00 00 15 80 00 CF" --watch-frame "07 80 45 20 D0 68" --watch-frame "07 80 45 30 D0 78" --log captures/rcp-buttons-cold-call-high-only.txt
Test C4: cold CALL low only, no physical button press.
python scripts/serial_button_response_test.py --port COM5 --duration 12 --prompt --startup-delay 1.0 --startup-frame "00 00 15 00 00 4F" --watch-frame "07 80 45 20 D0 68" --watch-frame "07 80 45 30 D0 78" --log captures/rcp-buttons-cold-call-low-only.txt
For each test, power-cycle first and do not press any panel buttons. If C1/C2
produce 0x45, the host can synthesize the CALL event path. If they do not,
the RCP's own physical CALL transition is required before the echo pair has
meaning.
2026-05-13 Cold No-Button CALL Injection Result
Captures:
captures/rcp-buttons-cold-call-pair-gap-50ms.txtcaptures/rcp-buttons-cold-call-pair-gap-80ms.txtcaptures/rcp-buttons-cold-call-high-only.txtcaptures/rcp-buttons-cold-call-low-only.txt
Observed result:
| Test | Host startup frame(s) | Result |
|---|---|---|
| C1 | 00 00 15 80 00 CF, 50 ms gap, 00 00 15 00 00 4F |
07 80 45 20 D0 68 |
| C2 | 00 00 15 80 00 CF, 80 ms gap, 00 00 15 00 00 4F |
07 80 45 20 D0 68 |
| C3 | 00 00 15 80 00 CF only |
heartbeat only |
| C4 | 00 00 15 00 00 4F only |
heartbeat only |
Interpretation:
- The host can synthesize the CALL
0x45response path without pressing the physicalCALLbutton. - The RCP does not require its own front-panel CALL transition before this path has meaning.
- The required trigger is the ordered CALL-high then CALL-low pair with a small inter-frame gap. Either frame alone is insufficient.
- This makes
00 00 15 80 00 CF -> 00 00 15 00 00 4Fa confirmed host-side event stimulus, not merely an echo of physical button traffic. - The response still returns to heartbeat afterward; this remains useful for protocol probing but is not yet an activation/session handshake.
Next CALL Tests
Two useful follow-ups now that the host can synthesize the CALL path:
- Determine whether the synthetic CALL trigger is repeatable within one power
cycle, or whether the first
0x45response latches/suppresses later ones. - Probe adjacent
0x45family responses that might drive the illuminated CALL button or another visible state.
CALL Retrigger / Latch Tests
Tooling note:
scripts/serial_button_response_test.pynow supports repeating the startup frame group with--startup-repeatand--startup-repeat-interval.
Test R1: two synthetic CALL trigger cycles, 2 second gap.
python scripts/serial_button_response_test.py --port COM5 --duration 16 --prompt --startup-delay 1.0 --startup-frame-interval 0.05 --startup-frame "00 00 15 80 00 CF" --startup-frame "00 00 15 00 00 4F" --startup-repeat 2 --startup-repeat-interval 2.0 --watch-frame "07 80 45 20 D0 68" --watch-frame "07 80 45 30 D0 78" --log captures/rcp-buttons-cold-call-repeat-2x-gap-2s.txt
Test R2: two synthetic CALL trigger cycles, 5 second gap.
python scripts/serial_button_response_test.py --port COM5 --duration 22 --prompt --startup-delay 1.0 --startup-frame-interval 0.05 --startup-frame "00 00 15 80 00 CF" --startup-frame "00 00 15 00 00 4F" --startup-repeat 2 --startup-repeat-interval 5.0 --watch-frame "07 80 45 20 D0 68" --watch-frame "07 80 45 30 D0 78" --log captures/rcp-buttons-cold-call-repeat-2x-gap-5s.txt
Test R3: three synthetic CALL trigger cycles, 2 second gap.
python scripts/serial_button_response_test.py --port COM5 --duration 24 --prompt --startup-delay 1.0 --startup-frame-interval 0.05 --startup-frame "00 00 15 80 00 CF" --startup-frame "00 00 15 00 00 4F" --startup-repeat 3 --startup-repeat-interval 2.0 --watch-frame "07 80 45 20 D0 68" --watch-frame "07 80 45 30 D0 78" --log captures/rcp-buttons-cold-call-repeat-3x-gap-2s.txt
Interpretation:
- If
Watch totalsshows one0x45hit per trigger cycle, this path is repeatable and not a one-shot latch. - If only the first cycle produces
0x45, treat the CALL path as latched until power cycle or some unknown reset. - If later cycles produce
07 80 45 30 D0 78instead of...20..., the RCP may be stepping through a small state machine rather than simply suppressing repeats.
Adjacent 0x45 Family Follow-Up Tests
Goal: once the synthetic CALL pair has produced 07 80 45 20 D0 68, send nearby
frames that might act like CALL lamp/tally control. Watch the CALL button lamp,
LCD, and serial stream after each follow-up.
Useful adjacent candidates:
| Candidate type | Follow-up frame | Why it is interesting |
|---|---|---|
| host-shaped command below | 00 00 44 20 D0 EE |
adjacent command byte |
| host-shaped command known | 00 00 45 20 D0 EF |
same command, host-shaped |
| host-shaped command above | 00 00 46 20 D0 EC |
adjacent command byte |
| exact-family sibling seen once | 07 80 45 30 D0 78 |
observed adjacent state |
| exact-family state below | 07 80 45 10 D0 58 |
nearby state nibble |
| exact-family command above | 07 80 46 20 D0 6B |
nearby command nibble |
Run each candidate in a separate power cycle. The startup CALL pair is used only
to make the RCP produce the known 0x45 response first.
Test A1:
python scripts/serial_button_response_test.py --port COM5 --duration 15 --prompt --startup-delay 1.0 --startup-frame-interval 0.05 --startup-frame "00 00 15 80 00 CF" --startup-frame "00 00 15 00 00 4F" --watch-frame "07 80 45 20 D0 68" --followup-on-watch-frame --followup-frame "00 00 44 20 D0 EE" --log captures/rcp-buttons-call-adjacent-44-host.txt
Test A2:
python scripts/serial_button_response_test.py --port COM5 --duration 15 --prompt --startup-delay 1.0 --startup-frame-interval 0.05 --startup-frame "00 00 15 80 00 CF" --startup-frame "00 00 15 00 00 4F" --watch-frame "07 80 45 20 D0 68" --followup-on-watch-frame --followup-frame "00 00 45 20 D0 EF" --log captures/rcp-buttons-call-adjacent-45-host.txt
Test A3:
python scripts/serial_button_response_test.py --port COM5 --duration 15 --prompt --startup-delay 1.0 --startup-frame-interval 0.05 --startup-frame "00 00 15 80 00 CF" --startup-frame "00 00 15 00 00 4F" --watch-frame "07 80 45 20 D0 68" --followup-on-watch-frame --followup-frame "00 00 46 20 D0 EC" --log captures/rcp-buttons-call-adjacent-46-host.txt
Test A4:
python scripts/serial_button_response_test.py --port COM5 --duration 15 --prompt --startup-delay 1.0 --startup-frame-interval 0.05 --startup-frame "00 00 15 80 00 CF" --startup-frame "00 00 15 00 00 4F" --watch-frame "07 80 45 20 D0 68" --followup-on-watch-frame --followup-frame "07 80 45 30 D0 78" --log captures/rcp-buttons-call-adjacent-45-state30.txt
Test A5:
python scripts/serial_button_response_test.py --port COM5 --duration 15 --prompt --startup-delay 1.0 --startup-frame-interval 0.05 --startup-frame "00 00 15 80 00 CF" --startup-frame "00 00 15 00 00 4F" --watch-frame "07 80 45 20 D0 68" --followup-on-watch-frame --followup-frame "07 80 45 10 D0 58" --log captures/rcp-buttons-call-adjacent-45-state10.txt
Test A6:
python scripts/serial_button_response_test.py --port COM5 --duration 15 --prompt --startup-delay 1.0 --startup-frame-interval 0.05 --startup-frame "00 00 15 80 00 CF" --startup-frame "00 00 15 00 00 4F" --watch-frame "07 80 45 20 D0 68" --followup-on-watch-frame --followup-frame "07 80 46 20 D0 6B" --log captures/rcp-buttons-call-adjacent-46-exact.txt
Record for each run:
- whether the CALL button lamp changes
- whether the LCD changes
- whether any non-heartbeat serial data appears after the follow-up
2026-05-13 Initial CALL Retrigger Result
Captures:
captures/rcp-buttons-cold-call-repeat-2x-gap-2s.txtcaptures/rcp-buttons-cold-call-repeat-2x-gap-5s.txtcaptures/rcp-buttons-cold-call-repeat-3x-gap-2s.txt
Observed result:
- All configured synthetic CALL trigger cycles were transmitted.
- Each run recorded only one visible
07 80 45 20 D0 68. - No LCD change was observed beyond the already known
CONNECT NOT ACT.
Important tooling limitation:
- In this first version of the repeat test, the helper sent all startup trigger groups before entering its main RX loop.
- That means the captured
0x45frame count is not a clean per-cycle measure. A single buffered0x45at the end does not prove whether only one cycle triggered or multiple triggers collapsed into one unread serial burst.
Interpretation:
- These runs suggest the CALL path may be latched or at least not obviously retriggering, but they are not strong enough to prove it.
- A corrected repeat test must read after each trigger group before sending the next one.
Tooling update:
scripts/serial_button_response_test.pynow supports--startup-read-after-group, which reads and logs RX after each startup-frame group before the next repeat.
Corrected repeat tests:
python scripts/serial_button_response_test.py --port COM5 --duration 16 --prompt --startup-delay 1.0 --startup-frame-interval 0.05 --startup-frame "00 00 15 80 00 CF" --startup-frame "00 00 15 00 00 4F" --startup-repeat 2 --startup-repeat-interval 2.0 --startup-read-after-group 0.8 --watch-frame "07 80 45 20 D0 68" --watch-frame "07 80 45 30 D0 78" --log captures/rcp-buttons-cold-call-repeat-2x-gap-2s-v2.txt
python scripts/serial_button_response_test.py --port COM5 --duration 22 --prompt --startup-delay 1.0 --startup-frame-interval 0.05 --startup-frame "00 00 15 80 00 CF" --startup-frame "00 00 15 00 00 4F" --startup-repeat 2 --startup-repeat-interval 5.0 --startup-read-after-group 0.8 --watch-frame "07 80 45 20 D0 68" --watch-frame "07 80 45 30 D0 78" --log captures/rcp-buttons-cold-call-repeat-2x-gap-5s-v2.txt
python scripts/serial_button_response_test.py --port COM5 --duration 24 --prompt --startup-delay 1.0 --startup-frame-interval 0.05 --startup-frame "00 00 15 80 00 CF" --startup-frame "00 00 15 00 00 4F" --startup-repeat 3 --startup-repeat-interval 2.0 --startup-read-after-group 0.8 --watch-frame "07 80 45 20 D0 68" --watch-frame "07 80 45 30 D0 78" --log captures/rcp-buttons-cold-call-repeat-3x-gap-2s-v2.txt
2026-05-13 Corrected CALL Retrigger Result
Captures:
captures/rcp-buttons-cold-call-repeat-2x-gap-2s-v2.txtcaptures/rcp-buttons-cold-call-repeat-2x-gap-5s-v2.txtcaptures/rcp-buttons-cold-call-repeat-3x-gap-2s-v2.txt
User observation:
- No LCD changes were observed beyond the already known
CONNECT NOT ACT.
Observed serial result:
| Test | Trigger groups sent | 0x45 result |
|---|---|---|
| 2x, 2 second gap | 2 | both groups produced 07 80 45 20 D0 68, four copies each |
| 2x, 5 second gap | 2 | only first group produced 07 80 45 20 D0 68 |
| 3x, 2 second gap | 3 | only first group produced 07 80 45 20 D0 68 |
Interpretation:
- The synthetic CALL path is not a strict one-shot latch, because the 2x/2s run clearly retriggered on the second group.
- It is also not cleanly repeatable on every later trigger, because the 2x/5s
and 3x/2s runs only produced the
0x45burst on the first group. - Each successful trigger can produce a short burst of repeated identical
07 80 45 20 D0 68frames rather than a single reply. - Current best model: the CALL path is re-enterable but phase/state-sensitive. Something about timing relative to the RCP's internal scan/heartbeat/session state affects whether later trigger groups are accepted.
Practical takeaway:
- We can use the synthetic CALL pair as a reproducible probe, but not yet as a guaranteed repeatable command in every cycle of a run.
- For future CALL-path experiments, treat one successful
0x45burst per power cycle as the reliable baseline, and repeated triggers as conditional behavior worth probing rather than assuming.
Next retrigger refinement:
python scripts/serial_button_response_test.py --port COM5 --duration 20 --prompt --startup-delay 1.0 --startup-frame-interval 0.05 --startup-frame "00 00 15 80 00 CF" --startup-frame "00 00 15 00 00 4F" --startup-repeat 2 --startup-repeat-interval 2.0 --startup-read-after-group 1.5 --watch-frame "07 80 45 20 D0 68" --watch-frame "07 80 45 30 D0 78" --log captures/rcp-buttons-cold-call-repeat-2x-gap-2s-read1500ms.txt
python scripts/serial_button_response_test.py --port COM5 --duration 23 --prompt --startup-delay 1.0 --startup-frame-interval 0.05 --startup-frame "00 00 15 80 00 CF" --startup-frame "00 00 15 00 00 4F" --startup-repeat 2 --startup-repeat-interval 3.0 --startup-read-after-group 1.5 --watch-frame "07 80 45 20 D0 68" --watch-frame "07 80 45 30 D0 78" --log captures/rcp-buttons-cold-call-repeat-2x-gap-3s-read1500ms.txt
These should help distinguish whether the second-trigger variability is caused by too-short post-trigger read windows, or by a genuine acceptance window/state inside the RCP.
2026-05-13 Adjacent 0x45 Follow-Up Result
Captures:
captures/rcp-buttons-call-adjacent-44-host.txtcaptures/rcp-buttons-call-adjacent-45-host.txtcaptures/rcp-buttons-call-adjacent-46-host.txtcaptures/rcp-buttons-call-adjacent-45-state30.txtcaptures/rcp-buttons-call-adjacent-45-state10.txtcaptures/rcp-buttons-call-adjacent-46-exact.txt
User observation:
- No LCD changes were observed beyond the already known
CONNECT NOT ACT. - No CALL button lamp change was observed in these runs.
Serial result:
| Test | Follow-up frame after 07 80 45 20 D0 68 |
Result |
|---|---|---|
| A1 | 00 00 44 20 D0 EE |
heartbeat only after follow-up |
| A2 | 00 00 45 20 D0 EF |
heartbeat only after follow-up |
| A3 | 00 00 46 20 D0 EC |
heartbeat only after follow-up |
| A4 | 07 80 45 30 D0 78 |
heartbeat only after follow-up |
| A5 | 07 80 45 10 D0 58 |
heartbeat only after follow-up |
| A6 | 07 80 46 20 D0 6B |
heartbeat only after follow-up |
Interpretation:
- None of the first adjacent
0x45family probes appear to drive the CALL lamp or advance the serial state. - The obvious nearby command/state variants are not enough on their own to act like a CALL lamp/tally command.
- The CALL
0x45family remains useful as a probe point, but the lamp control is probably elsewhere in the protocol or needs more session context.
2026-05-13 Outside-Region Clean Confirmation Result
Captures:
captures/rcp-outside-confirm-00-40-4f-8f-ef.txtcaptures/rcp-outside-repeat-00-40.txtcaptures/rcp-outside-repeat-00-4f.txtcaptures/rcp-outside-repeat-00-8f.txtcaptures/rcp-outside-repeat-00-ef.txtcaptures/rcp-outside-single-40.txtcaptures/rcp-outside-single-4f.txtcaptures/rcp-outside-single-8f.txtcaptures/rcp-outside-single-ef.txt
Goal:
- Clean-confirm whether the paused direct-sweep outliers
0x40,0x4F,0x8F, and0xEFare real primer-dependent queries outside the mappedA/B/Ctable. - Check whether they also work as single first-frame commands after boot.
Primer-pair result:
primer: 00 00 00 00 80 DA
candidate: 00 00 CMD 00 80 CHECKSUM
Observed responses:
| Pair | Multi-candidate confirm run | Single-candidate repeat | Current read |
|---|---|---|---|
00 -> 40 |
heartbeat only in the 4-candidate pass | 07 80 50 40 30 FD repeated |
confirmed real, but missed once in the shared sweep |
00 -> 4F |
07 80 0A 04 AB 78 |
07 80 0A 04 6B B8 repeated |
confirmed real, response bytes vary across runs |
00 -> 8F |
07 80 0C 04 AB 7E repeated |
07 80 0C 04 AB 7E once, then heartbeat |
confirmed real and stable in content |
00 -> EF |
07 80 0F 04 AB 7D repeated |
07 80 0F 04 AB 7D repeated |
confirmed real; differs from earlier paused-sweep 07 80 0F 04 EB 3D |
Single-frame control result:
All of these stayed heartbeat-compatible when sent as the first host frame after boot, with no anomalies recorded:
00 00 40 00 80 9A00 00 4F 00 80 9500 00 8F 00 80 5500 00 EF 00 80 35
Interpretation:
0x40,0x4F,0x8F, and0xEFare now confirmed as real primer-dependent readable/query responses outside the cleanA/B/Cmap.- None of the four behave like direct first-frame activation/session commands. They sit much closer to the broader query/status surface than to an unlatching handshake.
0x40appears slightly context- or timing-sensitive because it missed in the shared 4-candidate pass but reproduced cleanly when isolated.0x4Fand0xEFneed extra caution: the response family is real, but the value bytes are not yet fully nailed down across all captures.0x4Fhas been seen as both07 80 0A 04 AB 78and07 80 0A 04 6B B8.0xEFhas been seen as both07 80 0F 04 AB 7Dand the earlier paused direct-sweep07 80 0F 04 EB 3D.
- Best current model: these are legitimate outer-table queries whose returned payload can still depend on selector context, prior sequence, or exactly when in the panel's internal state machine they are sampled.
Host Identity / Capability Exchange Lead Ladder
Goal:
- Test whether the CCU is expected to identify itself before asking for capability/state blocks.
- Separate "query selector/page" behavior from "host identity/session setup" behavior.
- Check whether a short query burst behaves more like a capability poll than a single one-shot request.
Tooling:
- Use
scripts/serial_sequence_probe.pyfor fixed multi-frame sequences where the canonical primer stays constant and only later frames vary. - Use
scripts/serial_primer_candidate_sweep.pywhen only a simpleprimer -> candidatepair is needed.
Test HI1: Prefix Variation On A Stable Query
Keep the known-good primer fixed and vary only the prefix bytes of the A0
query frame. If the response changes, the host prefix bytes may carry CCU
identity, addressing, or mode information rather than being ignored padding.
Power-cycle before each run.
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 00 A0 00 80 7A" --read-after-frame 1.2 --log captures/rcp-hostid-prefix-0000-a0.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 80 A0 00 80 FA" --read-after-frame 1.2 --log captures/rcp-hostid-prefix-0080-a0.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "80 00 A0 00 80 FA" --read-after-frame 1.2 --log captures/rcp-hostid-prefix-8000-a0.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "07 80 A0 00 80 FD" --read-after-frame 1.2 --log captures/rcp-hostid-prefix-0780-a0.txt
What to watch for:
- Same
A0block as baseline: prefix bytes probably are not the missing host identity on their own. - Different structured block: prefix bytes likely select host identity, page, or role.
- Heartbeat only: that prefix pair may be invalid or reserved.
Test HI2: State/Value Variation On A Stable Query
Keep the canonical prefix and command byte, but vary the state/value fields on
the A0 query. This checks whether the host is supposed to present status or
capability bits in fields that we have mostly left at 00 80.
Power-cycle before each run.
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 00 A0 00 80 7A" --read-after-frame 1.2 --log captures/rcp-hostid-a0-0080.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 00 A0 20 D0 0A" --read-after-frame 1.2 --log captures/rcp-hostid-a0-20d0.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 00 A0 40 30 8A" --read-after-frame 1.2 --log captures/rcp-hostid-a0-4030.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 00 A0 60 30 AA" --read-after-frame 1.2 --log captures/rcp-hostid-a0-6030.txt
What to watch for:
- Same
A0block every time: host state/value fields may be ignored here. - Different block family or different returned value bytes: these fields may be host-presented capability/status bits.
- LCD/LED changes without a different serial block: possible session-state side effect rather than a simple table read.
Test HI3: Primer -> Host-Announce -> Query
Try likely selector/identity-looking bytes as a middle frame before the stable
A0 query. This is the direct "CCU says who it is first" test.
Power-cycle before each run.
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 00 90 00 80 4A" --frame "00 00 A0 00 80 7A" --read-after-frame 1.0 --log captures/rcp-hostid-announce-90-then-a0.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 00 9F 00 80 45" --frame "00 00 A0 00 80 7A" --read-after-frame 1.0 --log captures/rcp-hostid-announce-9f-then-a0.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 00 AF 00 80 75" --frame "00 00 A0 00 80 7A" --read-after-frame 1.0 --log captures/rcp-hostid-announce-af-then-a0.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 00 B7 00 80 6D" --frame "00 00 A0 00 80 7A" --read-after-frame 1.0 --log captures/rcp-hostid-announce-b7-then-a0.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 00 BB 00 80 61" --frame "00 00 A0 00 80 7A" --read-after-frame 1.0 --log captures/rcp-hostid-announce-bb-then-a0.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 00 FF 00 80 25" --frame "00 00 A0 00 80 7A" --read-after-frame 1.0 --log captures/rcp-hostid-announce-ff-then-a0.txt
What to watch for:
- Middle frame gets heartbeat only, third frame still returns plain
A0block: the announce byte probably is not sufficient. - Middle frame changes the later
A0response: strong evidence for a host-identity/selector stage. - Middle frame alone produces a new block: it may itself be a readable capability/identity query rather than a pure host announce.
Test HI4: Capability-Poll Block
Send a short family of related queries as if a CCU is polling multiple capability blocks in one startup pass. This checks whether the panel expects a cluster of reads instead of one isolated query.
Power-cycle before each run.
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 00 A0 00 80 7A" --frame "00 00 A1 00 80 7B" --frame "00 00 A4 00 80 7E" --frame "00 00 A5 00 80 7F" --read-after-frame 0.8 --log captures/rcp-hostid-capblock-a-family.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 00 B0 00 80 6A" --frame "00 00 B1 00 80 6B" --frame "00 00 B8 00 80 62" --frame "00 00 BC 00 80 66" --read-after-frame 0.8 --log captures/rcp-hostid-capblock-b-family.txt
What to watch for:
- Only the first query in the block responds: the one-shot model still dominates.
- Later queries also respond once the family is polled as a burst: this would be a major new lead toward CCU-style startup behavior.
- A later query changes the LCD or LEDs even if the first one looks ordinary: still worth treating as a lead.
Test HI5: Repeated Poll Group
Repeat the same short poll group with a gap, to test whether the panel wants periodic polling or whether only the first startup block matters.
Power-cycle before each run.
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 00 B0 00 80 6A" --frame "00 00 B1 00 80 6B" --repeat 3 --repeat-interval 1.5 --read-after-frame 0.8 --read-after-group 0.8 --log captures/rcp-hostid-repeat-b0-b1.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 00 A0 00 80 7A" --repeat 3 --repeat-interval 1.5 --read-after-frame 1.0 --read-after-group 0.8 --log captures/rcp-hostid-repeat-a0.txt
What to watch for:
- Only group 1 responds: startup window or latch behavior still dominates.
- Later groups begin to respond too: periodic polling may be part of the expected CCU session.
- A later group changes visible state even with similar serial output: possible session-timer or keepalive behavior.
Recommended order:
HI3because it most directly tests the "CCU identifies itself first" hypothesis.HI4because a capability-poll burst is a plausible Sony startup pattern.HI1andHI2if the first two stay flat and we need to isolate which host fields matter.
2026-05-13 Host Identity / Capability Result
Captures:
captures/rcp-hostid-prefix-0000-a0.txtcaptures/rcp-hostid-prefix-0080-a0.txtcaptures/rcp-hostid-prefix-8000-a0.txtcaptures/rcp-hostid-a0-0080.txtcaptures/rcp-hostid-a0-20d0.txtcaptures/rcp-hostid-a0-4030.txtcaptures/rcp-hostid-a0-6030.txtcaptures/rcp-hostid-announce-90-then-a0.txtcaptures/rcp-hostid-announce-9f-then-a0.txtcaptures/rcp-hostid-announce-af-then-a0.txtcaptures/rcp-hostid-announce-b7-then-a0.txtcaptures/rcp-hostid-announce-bb-then-a0.txtcaptures/rcp-hostid-announce-ff-then-a0.txtcaptures/rcp-hostid-capblock-a-family.txtcaptures/rcp-hostid-capblock-b-family.txtcaptures/rcp-hostid-repeat-a0.txtcaptures/rcp-hostid-repeat-b0-b1.txt
Not run / no capture present:
captures/rcp-hostid-prefix-0780-a0.txt
HI1: Prefix Variation On A0
Observed result:
| Query frame after primer | Result |
|---|---|
00 00 A0 00 80 7A |
conflicting captures: one run returned 07 80 E8 40 30 45, another returned 07 80 68 40 30 C5 |
00 80 A0 00 80 FA |
heartbeat only |
80 00 A0 00 80 FA |
heartbeat only |
07 80 A0 00 80 FD |
not run |
Read:
- Nonzero host prefix bytes did not help. The tested
00 80and80 00prefixes suppressed theA0response entirely. - The plain
00 00prefix remains the only confirmed working host prefix forA0, although the returned block still varies across runs.
HI2: State/Value Variation On A0
Observed result:
| Query frame after primer | Observed RCP response |
|---|---|
00 00 A0 00 80 7A |
07 80 68 40 30 C5 repeated |
00 00 A0 20 D0 0A |
07 80 E8 48 3A 47 repeated |
00 00 A0 40 30 8A |
07 80 68 58 26 CB repeated |
00 00 A0 60 30 AA |
07 80 68 58 26 CB repeated |
Read:
- This is the strongest new lead in the set.
- The
A0response is not fixed: the hoststate/valuefields clearly affect the returned block. - That strongly supports the idea that these fields are carrying host-presented status, selector, or capability information, not just filler.
HI3: Primer -> Host-Announce -> A0
Observed result:
| Sequence | Middle-frame result | Later A0 result |
|---|---|---|
00 -> 90 -> A0 |
07 80 64 40 30 C9 repeated |
no clean A0; only one more 07 80 64 40 30 C9 then heartbeat |
00 -> 9F -> A0 |
heartbeat only after 9F |
heartbeat only after A0; a prior anomaly 07 80 40 40 30 ED appeared immediately after the primer |
00 -> AF -> A0 |
07 80 0D 04 AB 7F visible with a leading heartbeat fragment |
heartbeat only after A0 |
00 -> B7 -> A0 |
07 80 1B 08 D6 18 repeated |
heartbeat only after A0 |
00 -> BB -> A0 |
07 80 37 10 2C D6 repeated |
no clean A0; only one more 07 80 37 10 2C D6 then heartbeat |
00 -> FF -> A0 |
heartbeat only | heartbeat only |
Read:
- The "announce" bytes behaved more like readable/query commands than like a host identity banner the panel accepts and then builds on.
- In most runs, the middle frame consumed the one-shot response opportunity and
the following
A0did not produce its own block. - So far this argues against a simple three-step handshake of
primer -> host identity -> query.
HI4: Capability-Poll Block
Observed result:
| Block | Result |
|---|---|
00 -> A0 -> A1 -> A4 -> A5 |
only A0 responded (07 80 68 40 30 C5); A1, A4, and A5 were heartbeat only |
00 -> B0 -> B1 -> B8 -> BC |
only B0 responded (07 80 EC 40 30 41 with a leading heartbeat fragment); B1, B8, and BC were heartbeat only |
Read:
- A burst of related readable queries did not unlock later responses in the same startup pass.
- The one-shot model still dominates: first successful readable query responds, later ones in the burst are suppressed.
HI5: Repeated Poll Group
Observed result:
| Repeated group | Result |
|---|---|
00 -> A0, repeated 3 times |
only group 1 produced 07 80 68 40 30 C5; groups 2 and 3 were heartbeat only |
00 -> B0 -> B1, repeated 3 times |
only group 1 B0 produced a response; later groups were heartbeat only and B1 never responded |
Read:
- Periodic polling without a power cycle did not open a sustained session.
- The panel still behaves like it offers one early readable response block, then falls back to heartbeat-only behavior.
Overall interpretation:
- The cleanest new evidence is that host
state/valuefields matter a lot for at least theA0family. - The tested nonzero prefixes do not look like a missing CCU identity by themselves.
- Candidate "announce" bytes mostly act like ordinary readable/query selectors, not like a reusable host identity stage.
- Capability-poll bursts and repeated poll groups did not create a multi-query session.
- Best current model: the startup exchange probably does involve host-presented status or selector bits, but the currently tested sequences still land in a one-shot query regime rather than an active maintained session.
Negative-Space Test Ladder
Goal:
- Find out what the panel quietly ignores versus what changes its internal parser/session state.
- Check whether repetitive "host heartbeat" traffic alone changes anything.
- Recheck whether a known readable query needs silence afterward, or whether the act of repetition itself suppresses later behavior.
- See whether a malformed checksum has any special effect beyond the already
known
CONNECT NOT ACTparser-visible state.
Recommended observation:
- Power-cycle before each test.
- Note any LCD change, especially whether it remains blank/idle or reaches the
usual
CONNECT NOT ACT. - Note any visible LED change, even if the serial log looks ordinary.
NS1: Assumed Host Heartbeat Only
Send only the current assumed host heartbeat frame repeatedly for a longer window, with no follow-up query.
python scripts/serial_probe_response.py --port COM5 --tx-frame "00 00 00 00 80 DA" --repeat 80 --interval 0.25 --delay 3 --after 3 --frame-size 0 --log captures/rcp-negative-heartbeat-only.txt
Read goal:
- If this alone eventually changes visible state, cadence may matter more than command diversity.
- If it remains heartbeat-only and visually inert, the primer/heartbeat frame is probably necessary but not sufficient.
2026-05-13 NS1 Partial Result
User observation from two power-cycled runs:
- During the entire
NS1script run, the panel did not enterCONNECT NOT ACT/CONNECTION NOT ACT. - About 2 seconds after the repeating heartbeat-only script stopped, the panel
entered
CONNECT NOT ACT. - Manually interrupting the script showed the same pattern: while the stream was
active, no
CONNECT NOT ACT; about 2 seconds after transmission ceased, the panel enteredCONNECT NOT ACT. - Once the panel was already in
CONNECT NOT ACT, restarting the heartbeat-only script did not immediately clear that state.
Interpretation:
- Continuous transmission of the assumed host heartbeat appears to hold the
panel out of the
CONNECT NOT ACTdisplay state. - The transition into
CONNECT NOT ACTnow looks less like "bad packet was received" and more like "host traffic stopped and a connection/activity timer expired." - That suggests the panel may treat regular host traffic as evidence of a live link, even when the session is not fully active.
- It also suggests
CONNECT NOT ACTmay be a post-timeout idle/failure state rather than an immediate parse-error state. - The fact that restarting the stream does not snap the LCD back out of
CONNECT NOT ACTimplies the entry condition and exit condition are probably different. Keeping traffic alive may prevent the state, but leaving the state may require a separate activation/ack/session step.
Next refinement worth doing:
- Repeat
NS1with different transmit intervals such as100 ms,500 ms, and1.5 sto estimate the timeout threshold for preventingCONNECT NOT ACT.
NS2: Primer Only, Short Burst Groups
Use the sequence probe to send the same primer in repeated groups, with a gap between groups, to see whether grouped startup chatter matters differently than an uninterrupted stream.
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --repeat 6 --repeat-interval 1.0 --read-after-frame 0.6 --read-after-group 0.6 --log captures/rcp-negative-primer-groups.txt
Read goal:
- If a later group produces anything non-heartbeat, the panel may have a boot window or cadence threshold.
- If every group is ignored, plain primer repetition is probably dead air from the panel's point of view.
NS3: Known Readable Query Once, Then Silence
Send a known readable query once after the canonical primer and then do nothing else for a longer read window.
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 00 A0 00 80 7A" --read-after-frame 1.2 --read-after-group 5.0 --log captures/rcp-negative-a0-once-then-silence.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 00 B0 00 80 6A" --read-after-frame 1.2 --read-after-group 5.0 --log captures/rcp-negative-b0-once-then-silence.txt
Read goal:
- If the panel emits extra delayed frames after the initial block, it may be expecting a host response or entering a timed wait state.
- If it cleanly returns to heartbeat-only, the one-shot read probably ends the interaction by itself.
NS4: Known Readable Query Repeated
Send the same readable query repeatedly after a primer, without power-cycling, to separate "one-shot per boot" from "suppressed only by mixed traffic."
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 00 A0 00 80 7A" --repeat 5 --repeat-interval 1.0 --read-after-frame 1.0 --read-after-group 0.8 --log captures/rcp-negative-a0-repeat.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 00 B0 00 80 6A" --repeat 5 --repeat-interval 1.0 --read-after-frame 1.0 --read-after-group 0.8 --log captures/rcp-negative-b0-repeat.txt
Read goal:
- If only the first group responds, that strengthens the one-shot-per-boot model.
- If a later group responds again, repeated identical polling may be more valid than mixed-family polling.
NS5: Malformed Checksum Once
Send one malformed checksum frame with the same shape as the assumed heartbeat, then observe whether the panel does anything beyond ordinary heartbeat and the known parser-visible display state.
python scripts/serial_probe_response.py --port COM5 --tx-frame "00 00 00 00 80 00" --repeat 1 --delay 3 --after 8 --frame-size 0 --log captures/rcp-negative-bad-heartbeat-once.txt
python scripts/serial_probe_response.py --port COM5 --tx-frame "00 00 A0 00 80 00" --repeat 1 --delay 3 --after 8 --frame-size 0 --log captures/rcp-negative-bad-a0-once.txt
Read goal:
- If malformed frames cause no special serial result beyond heartbeat, checksum errors are probably tolerated only enough to flip link-visible state.
- If malformed
A0produces a different visible or serial effect than malformed heartbeat, the parser may be doing more command-byte inspection before checksum rejection than expected.
NS6: Deliberate Silence Control
This is a no-transmit control to compare against all of the above. Just watch RX with no host traffic.
python scripts/serial_button_response_test.py --port COM5 --duration 20
Read goal:
- Confirm the natural idle pattern and visible state with zero host traffic in the exact same bench setup.
Recommended order:
NS6silence controlNS1heartbeat onlyNS3query once then silenceNS4repeated same queryNS5malformed checksum onceNS2primer groups
2026-05-13 Negative-Space Result
Captures:
captures/rcp-negative-heartbeat-only.txtcaptures/rcp-negative-heartbeat-100ms.txtcaptures/rcp-negative-heartbeat-500ms.txtcaptures/rcp-negative-heartbeat-1500ms.txtcaptures/rcp-negative-primer-groups.txtcaptures/rcp-negative-a0-once-then-silence.txtcaptures/rcp-negative-b0-once-then-silence.txtcaptures/rcp-negative-a0-repeat.txtcaptures/rcp-negative-b0-repeat.txtcaptures/rcp-negative-bad-heartbeat-once.txtcaptures/rcp-negative-bad-a0-once.txt
NS1: Assumed Host Heartbeat Only
Observed serial result:
- The repeated host heartbeat usually left RX at ordinary heartbeat, but some
runs produced a short early structured response burst near the second host
heartbeat:
07 80 40 60 30 CD07 80 40 40 30 ED07 80 C0 40 30 6D
- These bursts were transient. After them, the link returned to ordinary heartbeat RX while the host heartbeat stream continued.
Observed LCD/timing result from user notes:
100 msinterval:CONNECT NOT ACTappeared near the end before the script fully finished.500 msinterval:CONNECT NOT ACTappeared once the script finished.1500 msinterval: the panel timed out at the very end, just before the script finished.- Earlier manual observation also still stands: while the heartbeat stream is
actively running, the panel can remain out of
CONNECT NOT ACT, then fall into it roughly 2 seconds after traffic stops.
Read:
- Regular heartbeat traffic clearly affects the panel's visible connection timeout behavior.
- The panel is not treating
00 00 00 00 80 DAas a full activation command, but it does appear to treat it as meaningful host-presence traffic. - The brief
0x40/0xC0response bursts suggest some heartbeat cadences can momentarily steer the panel into a different readable state family even without an explicit query.
NS2: Primer Groups
Observed result:
- Repeated single-frame primer groups produced only heartbeat-compatible RX.
- No anomalies were logged.
Read:
- Sparse primer pings alone do not seem to provoke the panel into a readable state.
- Grouped startup chatter is weaker than a continuous heartbeat stream.
NS3: Known Query Once, Then Silence
Observed result:
| Sequence | Immediate response | Tail behavior |
|---|---|---|
00 -> A0, then silence |
07 80 68 40 30 C5 repeated |
a short additional 07 80 68 40 30 C5 tail, then heartbeat only |
00 -> B0, then silence |
07 80 6C 40 30 C1 repeated |
a short additional 07 80 6C 40 30 C1 tail, then heartbeat only |
Read:
- A successful one-shot readable query continues to drain out a short burst for a moment even after host transmission stops.
- After that short burst, the panel returns cleanly to ordinary heartbeat-only behavior.
NS4: Known Query Repeated
Observed result:
| Repeated sequence | Result |
|---|---|
00 -> A0, repeated 5 times |
only group 1 produced 07 80 68 40 30 C5; groups 2-5 were heartbeat only |
00 -> B0, repeated 5 times |
only group 1 produced 07 80 6C 40 30 C1; groups 2-5 were heartbeat only |
Read:
- Repeating the exact same known-good readable query does not make it reusable.
- This strengthens the one-shot-per-boot model for these query families.
NS5: Malformed Checksum Once
Observed result:
- A malformed heartbeat-shaped frame
00 00 00 00 80 00produced only ordinary heartbeat RX afterward. - A malformed
A0-shaped frame00 00 A0 00 80 00also produced only ordinary heartbeat RX afterward.
Read:
- Malformed frames do not seem to trigger a special serial reaction on their own.
- Whatever visible
CONNECT NOT ACTbehavior malformed frames may cause on the LCD, it is not accompanied by a distinctive RX response block in these runs.
Overall interpretation:
- Silence and malformed traffic are serially boring.
- Successful readable queries still behave as one-shot bursts followed by a return to heartbeat.
- Repeating those same queries still does not reopen them.
- Continuous heartbeat traffic is the one negative-space case that clearly
changes panel behavior:
- it can delay or suppress entry into
CONNECT NOT ACT - it can sometimes provoke brief
0x40/0xC0response-family bursts without any explicit query command
- it can delay or suppress entry into
Heartbeat-Maintained Reuse Test
Goal:
- Check whether keeping a host heartbeat alive between query attempts makes the one-shot readable blocks reusable without power-cycling.
Working idea:
- Earlier repeat tests used
primer -> querygroups with idle gaps. - The new negative-space tests suggest steady heartbeat traffic may hold the panel in a more connection-aware state.
- So the next question is whether interleaving regular heartbeats between query
attempts can reopen
A0orB0.
HR1: A0 With Heartbeat Maintenance
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 00 A0 00 80 7A" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 4 --frame-interval 0.25 --read-after-frame 0.35 --read-after-group 0.5 --log captures/rcp-heartbeat-maintained-a0.txt
HR2: B0 With Heartbeat Maintenance
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 00 B0 00 80 6A" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 4 --frame-interval 0.25 --read-after-frame 0.35 --read-after-group 0.5 --log captures/rcp-heartbeat-maintained-b0.txt
HR3: Denser Heartbeat Maintenance Around A0
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --frame "00 00 A0 00 80 7A" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 4 --frame-interval 0.10 --read-after-frame 0.25 --read-after-group 0.5 --log captures/rcp-heartbeat-maintained-a0-dense.txt
What to watch for:
- group 1 only responds: heartbeat maintenance is not enough; the latch still dominates
- later groups respond with the same readable block: heartbeat maintenance partially reopens the one-shot query path
- later groups do not return
A0/B0but do return0x40/0xC0blocks: heartbeat cadence may be moving the panel into a different selector/state family instead of truly reusing the original query
2026-05-13 Heartbeat-Maintained Reuse Result
Captures:
captures/rcp-heartbeat-maintained-a0.txtcaptures/rcp-heartbeat-maintained-b0.txtcaptures/rcp-heartbeat-maintained-a0-dense.txt
User LCD observation:
- In all three heartbeat-maintained runs, the panel never entered
CONNECT NOT ACT/CONNECTION NOT ACTwhile the script was running.
HR1: A0 With Heartbeat Maintenance
Observed result:
- Group 1:
A0produced07 80 68 40 30 C5- the next heartbeat frame drained the tail of that same
A0burst
- Groups 2-4:
A0produced heartbeat-compatible RX only- surrounding heartbeat frames also stayed heartbeat-only
Read:
- Keeping heartbeat traffic alive after the first
A0response did not makeA0reusable. - It did, however, keep the panel in the non-
CONNECT NOT ACTdisplay state.
HR2: B0 With Heartbeat Maintenance
Observed result:
- Group 1:
B0produced one readable block07 80 6C 40 30 C1
- Groups 2-4:
B0produced heartbeat-compatible RX only- surrounding heartbeat frames stayed heartbeat-only
Read:
- Same outcome as
A0: heartbeat maintenance did not reopen the one-shot query path forB0.
HR3: Denser Heartbeat Maintenance Around A0
Observed result:
- Group 1:
- the second heartbeat frame, before
A0, provoked07 80 40 40 30 ED - the following
A0frame itself produced only heartbeat-compatible RX
- the second heartbeat frame, before
- Groups 2-4:
- no
A0response - surrounding heartbeat frames stayed heartbeat-compatible
- no
Read:
- Denser heartbeat traffic can push the panel into the transient
0x40family state before theA0query arrives. - In that case, the heartbeat-induced
0x40response appears to consume the one-shot response opportunity and suppress theA0block.
Overall interpretation:
- Heartbeat maintenance is strong enough to affect the panel's visible
connection state, but not strong enough by itself to make
A0/B0reusable. - The latch/one-shot behavior still dominates the readable query families.
- Dense heartbeat traffic can compete with or displace a later explicit query by
provoking a transient
0x40-family response first. - Best current model:
- heartbeat cadence helps hold a "live host present" condition
- a separate selector/query opportunity still exists only once per boot or once per internal state phase
- some heartbeat cadences can spend that opportunity on
0x40/0xC0family responses instead ofA0/B0
Next branch worth testing:
- intentionally provoke the transient heartbeat-induced
0x40/0xC0family, then immediately query nearby commands to see whether that state exposes a new readable page - or combine heartbeat maintenance with the synthetic CALL path, to test whether "host present" plus an event-path trigger behaves differently than "host present" plus a plain table query
Camera-Info-Stream Hypothesis Ladder
Goal:
- Test the idea that the panel wants more than a plain link heartbeat.
- Treat one frame family as "host present" and another as possible camera-state/camera-info traffic.
- Check whether the transient heartbeat-induced
0x40/0xC0family is a different readable page or context, not just noise.
Working model:
- host heartbeat says "I am here"
- a second family says "here is current camera state"
- only then does the panel become fully active
CI1: Provoke 0x40 Family, Then Query B0
Use the same dense double-heartbeat pattern that previously provoked
07 80 40 40 30 ED, then immediately ask for a known B0 block.
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --frame "00 00 B0 00 80 6A" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 4 --frame-interval 0.10 --read-after-frame 0.25 --read-after-group 0.5 --log captures/rcp-camerainfo-40-then-b0.txt
Question:
- Does the
0x40family suppressB0, alterB0, or allow a differentB0response family than the normal07 80 6C 40 30 C1?
CI2: Provoke 0x40 Family, Then Query B5
Same idea, but use the strongest discovery-like block we have.
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --frame "00 00 B5 00 80 6F" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 4 --frame-interval 0.10 --read-after-frame 0.25 --read-after-group 0.5 --log captures/rcp-camerainfo-40-then-b5.txt
Question:
- If
B5is really a discovery/status block, does entering the heartbeat-driven0x40state make it return a different page, or consume it entirely?
CI3: Probe Commands Aligned With The Heartbeat-Induced Family
Try a simple 00 -> 40 and 00 -> C0 query again, but now with a small
heartbeat run-up first instead of a bare primer.
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --frame "00 00 40 00 80 9A" --read-after-frame 0.4 --read-after-group 1.0 --log captures/rcp-camerainfo-preheart-40.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --frame "00 00 C0 00 80 1A" --read-after-frame 0.4 --read-after-group 1.0 --log captures/rcp-camerainfo-preheart-c0.txt
Question:
- Do these commands return something closer to the transient
0x40/0xC0response families when the panel has just seen two host heartbeats?
CI4: Sustained Mixed Stream, Status-Block Style
Instead of repeating one query, rotate through a small set of known readable blocks while keeping heartbeat in the stream.
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 00 A0 00 80 7A" --frame "00 00 00 00 80 DA" --frame "00 00 B0 00 80 6A" --frame "00 00 00 00 80 DA" --frame "00 00 B5 00 80 6F" --repeat 3 --frame-interval 0.20 --read-after-frame 0.25 --read-after-group 0.8 --log captures/rcp-camerainfo-mixed-a0-b0-b5.txt
Question:
- Does a rotating "camera info block" stream behave differently from hammering a single one-shot query?
CI5: Sustained Mixed Stream, Heartbeat-Driven Family
Rotate heartbeat around 0x40-family and normal query candidates to see
whether the panel prefers a page/state rhythm instead of a static query.
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 00 40 00 80 9A" --frame "00 00 00 00 80 DA" --frame "00 00 B0 00 80 6A" --frame "00 00 00 00 80 DA" --frame "00 00 C0 00 80 1A" --repeat 3 --frame-interval 0.20 --read-after-frame 0.25 --read-after-group 0.8 --log captures/rcp-camerainfo-mixed-40-b0-c0.txt
Question:
- Does mixing the heartbeat-aligned family with a known readable block expose a reusable page, a new response family, or any visible panel state change?
CI6: Sparse Heartbeat Run-Up, Then A0
Try the same idea as the dense 0x40 trigger, but with slower heartbeat spacing
that previously nudged the 0xC0 family.
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --frame "00 00 A0 00 80 7A" --repeat 3 --frame-interval 1.50 --read-after-frame 0.45 --read-after-group 1.0 --log captures/rcp-camerainfo-c0-then-a0.txt
Question:
- Does a slower heartbeat-derived state family behave differently from the dense
0x40case?
What to watch for:
- the panel stays out of
CONNECT NOT ACTfor the whole run - a known readable block changes family or value fields
- a later query responds where it previously would not
- the transient
0x40/0xC0family appears immediately before a different stable block - any lamp or display change beyond the usual timeout behavior
Recommended order:
CI1CI2CI4CI5CI6
2026-05-13 Camera-Info-Stream Result
Captures:
captures/rcp-camerainfo-40-then-b0.txtcaptures/rcp-camerainfo-40-then-b5.txtcaptures/rcp-camerainfo-preheart-40.txtcaptures/rcp-camerainfo-preheart-c0.txtcaptures/rcp-camerainfo-mixed-a0-b0-b5.txtcaptures/rcp-camerainfo-mixed-40-b0-c0.txtcaptures/rcp-camerainfo-c0-then-a0.txt
User observation:
- In
CI6, the panel appeared to enterCONNECT NOT ACTand then emit a single latch/readable response afterward.
CI1: Provoke 0x40/0xC0, Then Query B0
Observed result:
- Group 1:
- the second heartbeat produced
07 80 C0 40 30 6D - the following
B0query produced only heartbeat-compatible RX
- the second heartbeat produced
- Groups 2-4:
- no structured
B0response - all later frames stayed heartbeat-compatible
- no structured
Read:
- The heartbeat-induced
0xC0family did not open a newB0page. - It appears to consume or displace the normal one-shot response opportunity.
CI2: Provoke 0x40, Then Query B5
Observed result:
- Group 1:
- the second heartbeat produced
07 80 40 40 30 ED - the following
B5query produced only heartbeat-compatible RX
- the second heartbeat produced
- Groups 2-4:
B5remained heartbeat-compatible only
Read:
- Same story as
CI1: the heartbeat-driven family does not seem to lead into a richerB5discovery page. - It suppresses or replaces it.
CI3: Probe Commands Aligned With The Heartbeat-Induced Family
Observed result:
| Sequence | Result |
|---|---|
double heartbeat, then 00 -> 40 |
heartbeat-induced 07 80 40 40 30 ED, then 00 -> 40 gave heartbeat only |
double heartbeat, then 00 -> C0 |
heartbeat-induced 07 80 40 40 30 ED, then 00 -> C0 only drained more 07 80 40 40 30 ED plus heartbeat |
Read:
- The pre-heartbeat
0x40state does not make the explicit40orC0commands bloom into a clear new readable block. - The explicit commands mostly arrive after the transient state is already in progress.
CI4: Sustained Mixed Stream, Status-Block Style
Observed result:
- Group 1:
A0produced07 80 68 40 30 C5- later
B0andB5in the same mixed stream were heartbeat only
- Groups 2-3:
A0,B0, andB5were all heartbeat-compatible only
Read:
- A rotating "camera info block" stream did not keep opening new readable status pages.
- The first successful block still wins, then the rest are suppressed.
CI5: Sustained Mixed Stream, Heartbeat-Driven Family
Observed result:
- Group 1:
00 -> 40produced07 80 50 40 30 FD- later
B0andC0in the same stream were heartbeat only
- Groups 2-3:
- all later frames were heartbeat-compatible only
Read:
- This confirms
00 -> 40is a stable explicit query family in its own right. - But, again, the first successful readable family suppresses later queries in the same stream.
CI6: Sparse Heartbeat Run-Up, Then A0
Observed result:
- Group 1:
- two widely spaced heartbeat frames stayed heartbeat-compatible
- the later
A0produced a delayed07 80 68 40 30 C5burst
- Groups 2-3:
- the same pattern returned heartbeat-compatible RX only
Read:
- This matches the user's observation well: a slow run-up can leave the panel
visibly in
CONNECT NOT ACT, yet a later single readable/latch response can still occur afterward. - That suggests the visible display state and the one-shot readable window are related, but not identical.
- A panel that has already fallen into
CONNECT NOT ACTmay still accept one later readable query under the right timing.
Overall interpretation:
- The "camera info stream" hypothesis is not wrong, but this particular test set did not show a sustained multi-block camera-state feed.
- The heartbeat-induced
0x40/0xC0family is real, but it mostly acts like a competing one-shot response family, not a gateway into a larger page. - Mixed streams still collapse into "first successful block wins."
- The cleanest new points are:
00 -> 40is a real explicit readable family:07 80 50 40 30 FD- heartbeat cadence can provoke
0x40/0xC0families without an explicit query - a visible
CONNECT NOT ACTstate does not completely forbid one later readable/latch response
Next branch worth testing:
- isolate the delayed-after-
CONNECT NOT ACTcase fromCI6with a small timing ladder around the finalA0 - compare
A0,B0, and40after a deliberate wait-until-CONNECT NOT ACTphase - test whether the
0x40/0xC0families are better thought of as alternate readable pages rather than camera-info keepalives
CONNECT NOT ACT vs Latch-State Decoupling Test
Goal:
- Prove that the visible
CONNECT NOT ACTstate and the one-shot readable/latch state are related, but not the same thing. - Show one case where the latch is spent even though the panel does not
enter
CONNECT NOT ACT. - Show another case where the panel does enter
CONNECT NOT ACTand can still produce one later readable response.
Interpretation target:
- If both paths happen, the LCD state is not a direct indicator of whether the one-shot readable window is still available.
DL1: Latch Spent While CONNECT NOT ACT Stays Away
This is the "no visible timeout, but latch already consumed" proof.
Watch the LCD throughout. The expected result is that the panel stays out of
CONNECT NOT ACT while running.
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 00 A0 00 80 7A" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 3 --frame-interval 0.25 --read-after-frame 0.35 --read-after-group 0.5 --log captures/rcp-decouple-no-connectnotact-a0.txt
What proves decoupling:
- group 1:
A0responds - later groups:
A0does not respond - LCD never enters
CONNECT NOT ACTduring the run
That shows the latch can be spent even while the display does not show the timeout/not-active state.
DL2: Deliberate CONNECT NOT ACT, Then Late A0
This is the "visible timeout, but one late readable response still exists" proof.
Method:
- power-cycle
- watch for the panel to show
CONNECT NOT ACTbetween the first heartbeat and the laterA0
python scripts/serial_sequence_probe.py --port COM5 --prompt --pre-read 1.0 --frame "00 00 00 00 80 DA" --frame "00 00 A0 00 80 7A" --frame-interval 2.50 --read-after-frame 0.30 --read-after-group 1.0 --log captures/rcp-decouple-connectnotact-then-a0.txt
What proves decoupling:
- the panel visibly enters
CONNECT NOT ACT - the later
A0still returns07 80 68 40 30 C5
That shows the visible CONNECT NOT ACT state does not automatically mean the
readable/latch opportunity is gone.
DL3: Deliberate CONNECT NOT ACT, Then Two Late A0 Queries
This tightens DL2 by checking whether the first late query can consume the
remaining one-shot readable window while the LCD state stays the same.
python scripts/serial_sequence_probe.py --port COM5 --prompt --pre-read 1.0 --frame "00 00 00 00 80 DA" --frame "00 00 A0 00 80 7A" --frame "00 00 A0 00 80 7A" --frame-interval 2.50 --read-after-frame 0.30 --read-after-group 1.0 --log captures/rcp-decouple-connectnotact-then-a0-a0.txt
What proves decoupling:
- panel enters
CONNECT NOT ACT - first late
A0responds - second late
A0does not - LCD remains in the same visible state
That shows the latch/readable state can change while the display state does not.
DL4: Compare Late A0, B0, and 40 After CONNECT NOT ACT
This checks whether only some readable families survive the visible timeout state.
python scripts/serial_sequence_probe.py --port COM5 --prompt --pre-read 1.0 --frame "00 00 00 00 80 DA" --frame "00 00 B0 00 80 6A" --frame-interval 2.50 --read-after-frame 0.30 --read-after-group 1.0 --log captures/rcp-decouple-connectnotact-then-b0.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --pre-read 1.0 --frame "00 00 00 00 80 DA" --frame "00 00 40 00 80 9A" --frame-interval 2.50 --read-after-frame 0.30 --read-after-group 1.0 --log captures/rcp-decouple-connectnotact-then-40.txt
Useful outcomes:
- only
A0responds late: the post-timeout window may be family-specific A0,B0, and40all respond late: the timeout state is clearly not the same as the latch state- none respond late:
the
CI6late response was timing-sensitive and needs a tighter delay ladder
DL5: Tight Delay Ladder Around Late A0
If DL2 or DL3 looks close but inconsistent, bracket the timeout edge.
python scripts/serial_sequence_probe.py --port COM5 --prompt --pre-read 1.0 --frame "00 00 00 00 80 DA" --frame "00 00 A0 00 80 7A" --frame-interval 2.00 --read-after-frame 0.30 --read-after-group 1.0 --log captures/rcp-decouple-delay-2000ms-a0.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --pre-read 1.0 --frame "00 00 00 00 80 DA" --frame "00 00 A0 00 80 7A" --frame-interval 2.25 --read-after-frame 0.30 --read-after-group 1.0 --log captures/rcp-decouple-delay-2250ms-a0.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --pre-read 1.0 --frame "00 00 00 00 80 DA" --frame "00 00 A0 00 80 7A" --frame-interval 2.50 --read-after-frame 0.30 --read-after-group 1.0 --log captures/rcp-decouple-delay-2500ms-a0.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --pre-read 1.0 --frame "00 00 00 00 80 DA" --frame "00 00 A0 00 80 7A" --frame-interval 2.75 --read-after-frame 0.30 --read-after-group 1.0 --log captures/rcp-decouple-delay-2750ms-a0.txt
Recommended order:
DL1DL2DL3DL4DL5only ifDL2/DL3are close but inconsistent
2026-05-13 CONNECT NOT ACT vs Latch-State Decoupling Result
Captures:
captures/rcp-decouple-no-connectnotact-a0.txtcaptures/rcp-decouple-connectnotact-then-a0.txtcaptures/rcp-decouple-connectnotact-then-a0-a0.txt
User LCD observation:
DL1: the panel never presentedCONNECT NOT ACTwhile the script was running.DL2andDL3: the panel presentedCONNECT NOT ACTat the start of the script.
DL1: Latch Spent While CONNECT NOT ACT Stays Away
Observed result:
- Group 1:
A0produced a readable block, but this run returned07 80 E8 40 30 45rather than07 80 68 40 30 C5
- Groups 2-3:
A0produced heartbeat-compatible RX only
- LCD:
- no
CONNECT NOT ACTwhile the script was active
- no
Read:
- This is strong evidence for decoupling in one direction:
the readable/latch state can be consumed while the panel does not show
CONNECT NOT ACT. - It also reinforces that the
A0family can vary between at least68andE8forms depending on context/timing.
DL2: Deliberate CONNECT NOT ACT, Then Late A0
Observed result:
- The panel showed
CONNECT NOT ACTearly in the run. - The later
A0query produced heartbeat-compatible RX only. - No delayed
A0readable block appeared at this exact timing.
Read:
- At a
2.50 sgap in this two-frame form, visibleCONNECT NOT ACTdid not guarantee a late readable response. - This weakens the simple "enter
CONNECT NOT ACT, thenA0always still works once" idea.
DL3: Deliberate CONNECT NOT ACT, Then Two Late A0 Queries
Observed result:
- The panel showed
CONNECT NOT ACTearly in the run. - Both later
A0queries produced heartbeat-compatible RX only. - No readable block appeared on either late
A0.
Read:
- This does not provide the hoped-for second half of the decoupling proof.
- Instead, it says that once the panel has visibly entered
CONNECT NOT ACTin this specific timing pattern, the lateA0opportunity may already be gone or may require narrower timing than2.50 s.
Overall interpretation:
- We now have solid evidence for one half of the claim:
CONNECT NOT ACTis not required for the latch/readable state to be consumed. - We do not yet have equally solid evidence for the other half at this
timing:
a visible
CONNECT NOT ACTstate did not still yield a lateA0response inDL2orDL3. - So the current safest statement is:
the LCD state and the latch/readable state are not directly coupled, but the
exact post-timeout behavior is more timing-sensitive than the earlier
CI6observation first suggested.
Best next move:
- run
DL4and then a tightDL5delay bracket - especially around
2.00 s,2.25 s,2.50 s, and2.75 s - because the difference between the earlier
CI6late hit and these no-hit decoupling runs is now most likely timing, framing shape, or both
Heartbeat-Family Echo Probes
Goal:
- Test whether the newer heartbeat-induced response families behave more like camera-state blocks that the host is expected to mirror or acknowledge.
- Compare exact echo versus host-shaped mirror for the same apparent payload.
Best current echo candidates:
- heartbeat-induced:
07 80 40 40 30 ED07 80 40 60 30 CD07 80 C0 40 30 6D
- explicit
00 -> 40family:07 80 50 40 30 FD
- context-sensitive
A0variant:07 80 E8 40 30 45
Host-shaped mirrors:
00 00 40 40 30 6A00 00 40 60 30 4A00 00 C0 40 30 EA00 00 50 40 30 7A00 00 E8 40 30 C2
HE1: Exact Echo Of 07 80 40 40 30 ED
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --frame "07 80 40 40 30 ED" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 3 --frame-interval 0.10 --read-after-frame 0.25 --read-after-group 0.5 --log captures/rcp-heartbeat-echo-exact-404030ed.txt
HE2: Host-Shaped Mirror Of 07 80 40 40 30 ED
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --frame "00 00 40 40 30 6A" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 3 --frame-interval 0.10 --read-after-frame 0.25 --read-after-group 0.5 --log captures/rcp-heartbeat-echo-host-404030.txt
HE3: Exact Echo Of 07 80 C0 40 30 6D
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --frame "07 80 C0 40 30 6D" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 3 --frame-interval 0.10 --read-after-frame 0.25 --read-after-group 0.5 --log captures/rcp-heartbeat-echo-exact-c040306d.txt
HE4: Host-Shaped Mirror Of 07 80 C0 40 30 6D
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --frame "00 00 C0 40 30 EA" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 3 --frame-interval 0.10 --read-after-frame 0.25 --read-after-group 0.5 --log captures/rcp-heartbeat-echo-host-c04030.txt
HE5: Exact Echo Of Explicit 00 -> 40 Response
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 40 00 80 9A" --frame "07 80 50 40 30 FD" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.6 --log captures/rcp-heartbeat-echo-exact-504030fd.txt
HE6: Host-Shaped Mirror Of Explicit 00 -> 40 Response
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 40 00 80 9A" --frame "00 00 50 40 30 7A" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.6 --log captures/rcp-heartbeat-echo-host-504030.txt
HE7: Echo The A0 Variant From DL1
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 A0 00 80 7A" --frame "07 80 E8 40 30 45" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.6 --log captures/rcp-heartbeat-echo-exact-e8403045.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 A0 00 80 7A" --frame "00 00 E8 40 30 C2" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.6 --log captures/rcp-heartbeat-echo-host-e84030.txt
What would count as a hit:
- any new non-heartbeat RCP frame after the echo/mirror
- the panel leaving or changing behavior around
CONNECT NOT ACT - a previously one-shot query family becoming readable again
- the echo path producing a repeatable family-specific response
Recommended order:
HE2HE4HE1HE3HE6HE7
2026-05-13 Heartbeat-Family Echo Result
Captures:
captures/rcp-heartbeat-echo-host-404030.txtcaptures/rcp-heartbeat-echo-host-c04030.txtcaptures/rcp-heartbeat-echo-exact-404030ed.txtcaptures/rcp-heartbeat-echo-exact-c040306d.txtcaptures/rcp-heartbeat-echo-host-504030.txtcaptures/rcp-heartbeat-echo-exact-504030fd.txtcaptures/rcp-heartbeat-echo-exact-e8403045.txtcaptures/rcp-heartbeat-echo-host-e84030.txt
HE1 / HE2 / HE3 / HE4: Echoing The Heartbeat-Induced 0x40 / 0xC0 Families
Observed result:
07 80 40 40 30 EDexact echo: no new structured response after the echo.00 00 40 40 30 6Ahost-shaped mirror: no new structured response after the mirror.07 80 C0 40 30 6Dexact echo: no new structured response after the echo.00 00 C0 40 30 EAhost-shaped mirror: no new structured response after the mirror.
Read:
- The heartbeat-induced
0x40/0xC0families do not currently look like payloads the panel expects to receive back as an echo or mirror. - They behave more like one-way readable/context responses than a bidirectional acknowledge-and-continue exchange.
HE5 / HE6: Echoing The Explicit 00 -> 40 Response Family
Observed result:
00 -> 40again produced the known readable block07 80 50 40 30 FD.- Exact echo of that block,
07 80 50 40 30 FD, produced no new structured response. - Host-shaped mirror,
00 00 50 40 30 7A, also produced no new structured response. - In the host-shaped mirror run, a later plain heartbeat again provoked the
transient
07 80 40 40 30 EDfamily rather than any direct reply to the mirror.
Read:
- The explicit
00 -> 40family also does not behave like something the panel wants echoed back in either exact or host-shaped form. - The reappearance of
07 80 40 40 30 EDafter the mirror reinforces that the heartbeat/context state machine is still active in the background and can dominate what happens next.
HE7: Echoing The A0 Variant From DL1
Observed result:
Two distinct outcomes appeared here:
- Exact echo path:
00 -> A0did not log its usual readable block in the immediate window- sending exact
07 80 E8 40 30 45produced a new unexpected response:07 C0 7A 50 A6 11
- Host-shaped mirror path:
00 00 E8 40 30 C2produced another new structured response:07 80 FA 50 26 51
Read:
- This is the first heartbeat-family echo probe set that produced genuinely new structured responses rather than just heartbeat.
- The
E8/FAarea now looks much more interesting than the40/C0exact echo families. - We do not yet know whether:
07 C0 7A 50 A6 11is a valid stable family or a context-fragmented reply07 80 FA 50 26 51is a proper readable page, an error/status block, or a transformed reply to theE8-family mirror
- But these are strong enough to treat as new leads rather than noise.
Overall interpretation:
- Most heartbeat-family responses do not behave like simple values the host should echo back.
- The exception is the
A0-variant /E8area, where echoing or host-mirroring produced fresh structured responses. - So the most promising echo branch is no longer generic
40/C0heartbeat mirroring, but focused follow-up around:07 80 E8 40 30 4507 80 FA 50 26 5107 C0 7A 50 A6 11
Next branch worth testing:
- reproduce the
E8-mirror path cleanly and see whetherFAand7Aare stable - try host-shaped and exact echoes of
07 80 FA 50 26 51 - probe whether
FA/7Acorrespond to nearby explicit host queries such as00 -> FAor00 -> 7A
HE8: Exact Echo Of 07 80 FA 50 26 51
Recreate the E8 host-mirror path that previously produced
07 80 FA 50 26 51, then immediately send the exact FA frame back.
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 A0 00 80 7A" --frame "00 00 E8 40 30 C2" --frame "07 80 FA 50 26 51" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-heartbeat-echo-exact-fa502651.txt
HE9: Host-Shaped Mirror Of 07 80 FA 50 26 51
Host-shaped checksum for 00 00 FA 50 26 ?? is D6.
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 A0 00 80 7A" --frame "00 00 E8 40 30 C2" --frame "00 00 FA 50 26 D6" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-heartbeat-echo-host-fa5026.txt
What would count as a hit:
- any fresh structured response after the
FAecho or mirror - a repeat of
07 80 FA 50 26 51or07 C0 7A 50 A6 11 - any new family in the
50/7A/FAregion - visible panel behavior changing beyond the usual
CONNECT NOT ACT
2026-05-13 FA Echo Follow-Up Result
Captures:
captures/rcp-heartbeat-echo-exact-fa502651.txtcaptures/rcp-heartbeat-echo-host-fa5026.txt
Result summary:
- Both runs behaved the same way.
- In group 1, the host-shaped
E8step00 00 E8 40 30 C2produced a new structured family:07 80 7A 50 26 D1 - That
7Afamily appeared twice immediately after theE8host-mirror step in both runs. - The following
FAstep, whether exact echo07 80 FA 50 26 51or host-shaped mirror00 00 FA 50 26 D6, did not produce a fresh distinct reply. The receive window only showed one more07 80 7A 50 26 D1followed by heartbeat. - In group 2, both runs were heartbeat-only after the same sequence.
Interpretation:
- The meaningful branch point still appears to be the host-shaped
E8frame, not the subsequentFAecho/mirror. 07 80 FA 50 26 51is not yet behaving like a value the host should directly answer to advance the exchange.07 80 7A 50 26 D1is now a stronger candidate for a real sibling response family in this branch than07 C0 7A 50 A6 11, because it reproduced in both HE8 and HE9 group-1 runs.- The fact that HE8 and HE9 were serially identical suggests the panel likely
emitted a delayed/queued
7A-family response from theE8host-mirror step, rather than parsing theFAfollow-up as a meaningful new command.
Best current model of this branch:
00 00 E8 40 30 C2can lead into a7A/FAresponse family.07 80 FA 50 26 51may be one branch member, but answering it directly did not produce a second-stage exchange.- The next useful probe should probably target
07 80 7A 50 26 D1directly, or compare exact-vs-host handling of7Arather thanFA.
HE10: Exact Echo Of 07 80 7A 50 26 D1
Recreate the host-shaped E8 path that now reproducibly yields
07 80 7A 50 26 D1, then immediately send that exact 7A frame back.
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 A0 00 80 7A" --frame "00 00 E8 40 30 C2" --frame "07 80 7A 50 26 D1" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-heartbeat-echo-exact-7a5026d1.txt
HE11: Host-Shaped Mirror Of 07 80 7A 50 26 D1
Host-shaped checksum for 00 00 7A 50 26 ?? is 56.
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 A0 00 80 7A" --frame "00 00 E8 40 30 C2" --frame "00 00 7A 50 26 56" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-heartbeat-echo-host-7a5026.txt
What would count as a hit:
- any new non-heartbeat response after the
7Aecho or mirror - a stable second-stage family after
07 80 7A 50 26 D1 - recurrence of
FA,7A, or another new50-region family - any visible panel behavior change beyond the usual
CONNECT NOT ACT
2026-05-13 7A Echo Follow-Up Result
Captures:
captures/rcp-heartbeat-echo-exact-7a5026d1.txtcaptures/rcp-heartbeat-echo-host-7a5026.txt
Result summary:
- Both runs again point to the host-shaped
E8step as the meaningful branch trigger. - In group 1,
00 00 E8 40 30 C2reproduced07 80 7A 50 26 D1in both tests. - The exact-echo run was the cleanest:
00 00 E8 40 30 C2produced one07 80 7A 50 26 D1- exact echo
07 80 7A 50 26 D1produced only heartbeat afterwards
- The host-shaped mirror run behaved like the earlier
FAtests:00 00 E8 40 30 C2produced07 80 7A 50 26 D1twice- host-shaped
00 00 7A 50 26 56then only drained one more07 80 7A 50 26 D1followed by heartbeat
- In group 2, both tests were heartbeat-only after the same sequence.
Interpretation:
07 80 7A 50 26 D1is now a confirmed reproducible response family on the host-shapedE8branch.- But directly echoing
7A, whether exact or host-shaped, still did not create a second-stage exchange, visible state change, or reusable session behavior. - This makes
7Alook more like another readable/event family emitted by the branch, not yet like the next host command the panel expects. - The asymmetry is useful:
- host-shaped
E8can provoke7A 7Aitself does not obviously provoke anything back
- host-shaped
Best current model of the E8 branch:
00 00 E8 40 30 C2is the active stimulus.07 80 7A 50 26 D1is the most reproducible downstream response in that branch.07 80 FA 50 26 51and07 C0 7A 50 A6 11remain side-family observations, but neither has overtaken7Aas the strongest lead.
HE12: Nearby Host-Shaped E8 Neighbors
Test whether the 7A branch is specific to E8, or whether nearby host-shaped
commands in the same region also provoke structured responses.
Checksums:
00 00 E7 40 30 CD00 00 E9 40 30 C300 00 EA 40 30 C0
HE12a: Host-Shaped E7
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 A0 00 80 7A" --frame "00 00 E7 40 30 CD" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-heartbeat-neighbor-e7.txt
HE12b: Host-Shaped E9
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 A0 00 80 7A" --frame "00 00 E9 40 30 C3" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-heartbeat-neighbor-e9.txt
HE12c: Host-Shaped EA
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 A0 00 80 7A" --frame "00 00 EA 40 30 C0" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-heartbeat-neighbor-ea.txt
What would count as a hit:
- any non-heartbeat response after
E7,E9, orEA - recurrence of
07 80 7A 50 26 D1 - recurrence of
07 80 FA 50 26 51or07 C0 7A 50 A6 11 - any new stable family that suggests
E8belongs to a broader selector block
2026-05-13 E8 Neighbor Result
Captures:
captures/rcp-heartbeat-neighbor-e7.txtcaptures/rcp-heartbeat-neighbor-e9.txtcaptures/rcp-heartbeat-neighbor-ea.txt
Result summary:
E7,E9, andEAdo not behave the same way, so this is not a simple "everything aroundE8lands in the same branch" region.- All three effects only appeared in group 1. Group 2 was heartbeat-only in every run.
Observed outputs:
| Host step | Structured result |
|---|---|
00 00 E7 40 30 CD |
later heartbeat provoked 07 80 40 40 30 ED |
00 00 E9 40 30 C3 |
produced 07 80 7A 28 D3 5C |
00 00 EA 40 30 C0 |
later heartbeat provoked 07 80 C0 40 30 6D |
Interpretation:
E8still appears special, because it is the one that most cleanly enters the reproducible07 80 7A 50 26 D1branch.E9is the first nearby neighbor to produce a clearly related but distinct7A-family frame:07 80 7A 28 D3 5C
E7andEAlook more like they bias the panel toward known heartbeat-family transients (07 80 40 40 30 EDand07 80 C0 40 30 6D) rather than the7A/FAbranch.- So the emerging picture is not a broad contiguous "E* equals same page" block, but a mixed neighborhood where nearby host-shaped values steer the panel into different transient/readable families.
Best current follow-up:
- treat
E9as the strongest neighbor lead - test exact and host-shaped handling of
07 80 7A 28 D3 5C - optionally compare
E8vsE9timing to see whether the differing7Apayloads reflect selector choice or timing/context
HE13: Exact Echo Of 07 80 7A 28 D3 5C
Recreate the E9 neighbor path, then immediately send the exact 7A-family
response back to the panel.
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 A0 00 80 7A" --frame "00 00 E9 40 30 C3" --frame "07 80 7A 28 D3 5C" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-heartbeat-echo-exact-7a28d35c.txt
HE14: Host-Shaped Mirror Of 07 80 7A 28 D3 5C
Host-shaped checksum for 00 00 7A 28 D3 ?? is DB.
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 A0 00 80 7A" --frame "00 00 E9 40 30 C3" --frame "00 00 7A 28 D3 DB" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-heartbeat-echo-host-7a28d3.txt
What would count as a hit:
- any non-heartbeat response after the exact or host-shaped
7A 28 D3frame - a repeat of
07 80 7A 28 D3 5C - crossover into the
E8-style07 80 7A 50 26 D1or07 80 FA 50 26 51branch - any new stable family that suggests
E9is a second entry point into the same broader selector surface
2026-05-13 E9 Mirror Result
Captures:
captures/rcp-heartbeat-echo-exact-7a28d35c.txtcaptures/rcp-heartbeat-echo-host-7a28d3.txt
Result summary:
E9cleanly reproduced its7A-family response in group 1 in both tests:07 80 7A 28 D3 5C
- Exact echo
07 80 7A 28 D3 5Cproduced only heartbeat afterwards. - Host-shaped mirror
00 00 7A 28 D3 DBdid not open a new stage either; it only drained more copies of07 80 7A 28 D3 5Cbefore falling back to heartbeat. - Group 2 was heartbeat-only in both tests.
Interpretation:
E9behaves very much like theE8branch structurally:- the host-shaped
E9step is the active stimulus - the downstream
7Aresponse is real and reproducible - but directly echoing or mirroring that
7Aresponse does not advance the exchange
- the host-shaped
- So
E8andE9now look like sibling selector-style entry points into related but distinct7A-family outputs:E8->07 80 7A 50 26 D1E9->07 80 7A 28 D3 5C
- This strengthens the idea that the
Exregion may be selecting pages or classes of status rather than carrying the real session-advance command.
Best current next move:
- test more nearby
Exvalues to see whether this is a broader selector strip - or try explicit host queries for the downstream family bytes (
00 -> 7A,00 -> FA) afterE8/E9selection
HE15: Continue Outward In The Ex Neighborhood
Push one step farther out from the now-interesting E8 / E9 region and see
whether the selector-like behavior continues, shifts family again, or collapses
back into heartbeat-only behavior.
Checksums:
00 00 E6 40 30 CC00 00 EB 40 30 C100 00 EC 40 30 C6
HE15a: Host-Shaped E6
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 A0 00 80 7A" --frame "00 00 E6 40 30 CC" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-heartbeat-neighbor-e6.txt
HE15b: Host-Shaped EB
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 A0 00 80 7A" --frame "00 00 EB 40 30 C1" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-heartbeat-neighbor-eb.txt
HE15c: Host-Shaped EC
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 A0 00 80 7A" --frame "00 00 EC 40 30 C6" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-heartbeat-neighbor-ec.txt
What would count as a hit:
- any new non-heartbeat response after
E6,EB, orEC - recurrence of the
E8-style07 80 7A 50 26 D1orE9-style07 80 7A 28 D3 5C - recurrence of known heartbeat-family transients like
07 80 40 40 30 EDor07 80 C0 40 30 6D - any additional family that strengthens the idea of a selector strip across
the
Exregion
2026-05-13 Outward Ex Result
Captures:
captures/rcp-heartbeat-neighbor-e6.txtcaptures/rcp-heartbeat-neighbor-eb.txtcaptures/rcp-heartbeat-neighbor-ec.txt
Result summary:
E6andEBbehaved the same way:- no immediate structured reply at the
Exstep - the following heartbeat provoked
07 80 40 40 30 ED
- no immediate structured reply at the
ECproduced a new structured family in group 1:07 80 7B 50 26 D0
- As with the other recent selector tests, all interesting behavior was group 1 only. Group 2 was heartbeat-only.
Observed outputs:
| Host step | Structured result |
|---|---|
00 00 E6 40 30 CC |
later heartbeat provoked 07 80 40 40 30 ED |
00 00 EB 40 30 C1 |
later heartbeat provoked 07 80 40 40 30 ED |
00 00 EC 40 30 C6 |
produced 07 80 7B 50 26 D0 |
Interpretation:
- The
Exneighborhood is continuing to look like a selector-like strip with mixed outcomes, not a uniform command class. E6,E7, andEBnow cluster together as values that bias into the07 80 40 40 30 EDheartbeat-family transient.E8andE9open distinct7A-family responses:E8->07 80 7A 50 26 D1E9->07 80 7A 28 D3 5C
ECnow extends that pattern one step further with a new sibling:EC->07 80 7B 50 26 D0
EAremains its own case steering toward07 80 C0 40 30 6D.
Best current follow-up:
- treat
ECas the next strong lead and test exact/host-shaped handling of07 80 7B 50 26 D0 - optionally try
EDnext to see whether the7Bbranch continues
HE16: Exact Echo Of 07 80 7B 50 26 D0
Recreate the EC selector path, then immediately send the exact 7B-family
response back to the panel.
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 A0 00 80 7A" --frame "00 00 EC 40 30 C6" --frame "07 80 7B 50 26 D0" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-heartbeat-echo-exact-7b5026d0.txt
HE17: Host-Shaped Mirror Of 07 80 7B 50 26 D0
Host-shaped checksum for 00 00 7B 50 26 ?? is 57.
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 A0 00 80 7A" --frame "00 00 EC 40 30 C6" --frame "00 00 7B 50 26 57" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-heartbeat-echo-host-7b5026.txt
What would count as a hit:
- any non-heartbeat response after the exact or host-shaped
7B 50 26frame - a repeat of
07 80 7B 50 26 D0 - crossover into the
7A-family branches or any new sibling family - any sign that
ECis a second-stage exchange rather than just another selector-produced readable response
2026-05-13 EC Mirror Result
Captures:
captures/rcp-heartbeat-echo-exact-7b5026d0.txtcaptures/rcp-heartbeat-echo-host-7b5026.txt
Result summary:
ECdid not behave exactly like the earlierE8/E9branches.- In the host-shaped mirror run:
00 00 EC 40 30 C6reproduced07 80 7B 50 26 D0in group 1- host-shaped mirror
00 00 7B 50 26 57did not advance the exchange; it only drained one more07 80 7B 50 26 D0and then returned to heartbeat
- In the exact-echo run:
- the
ECselector step itself did not expose the7Bfamily inside the immediate read window - but exact echo
07 80 7B 50 26 D0produced a fresh new family:07 C0 2F 95 09 2E - that new family appeared twice in group 1, then the run returned to heartbeat
- the
- Group 2 was heartbeat-only in both runs.
Interpretation:
ECis the firstExselector case so far where the exact downstream echo appears to matter more than the host-shaped mirror.- That makes the
7Bbranch more interesting than the7Abranches:E8/E9downstream7Aechoes did not produce a clean second-stage family- exact
7Becho produced07 C0 2F 95 09 2E
07 C0 2F 95 09 2Eis now a strong follow-up target. It may be:- a second-stage response
- a different page/family reached through exact
7Becho - or a context-specific branch member that only appears on the exact-echo path
Best current follow-up:
- test exact and host-shaped handling of
07 C0 2F 95 09 2E - optionally compare whether exact
EC -> 7Becho is timing-sensitive, since the host-shaped mirror path did not reach the same family
HE18: Exact Echo Of 07 C0 2F 95 09 2E
Recreate the EC -> 7B exact-echo branch, then immediately send the new
2F 95 09 family frame back exactly as seen.
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 A0 00 80 7A" --frame "00 00 EC 40 30 C6" --frame "07 80 7B 50 26 D0" --frame "07 C0 2F 95 09 2E" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-heartbeat-echo-exact-2f95092e.txt
HE19: Host-Shaped Mirror Of 07 C0 2F 95 09 2E
Host-shaped checksum for 00 00 2F 95 09 ?? is E9.
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 A0 00 80 7A" --frame "00 00 EC 40 30 C6" --frame "07 80 7B 50 26 D0" --frame "00 00 2F 95 09 E9" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-heartbeat-echo-host-2f9509.txt
What would count as a hit:
- any non-heartbeat response after the exact or host-shaped
2F 95 09frame - a repeat of
07 C0 2F 95 09 2E - any fresh family after the
2Fstage that suggests a real chained exchange - any sign that the
EC -> 7B -> 2Fpath is the closest thing yet to a proper request/response ladder
2026-05-13 2F Mirror Result
Captures:
captures/rcp-heartbeat-echo-exact-2f95092e.txtcaptures/rcp-heartbeat-echo-host-2f9509.txt
Result summary:
- These runs did not extend the
EC -> 7B -> 2Fpath into a stable next stage. - Instead, group 1 shifted the
ECselector response itself into a new sibling family:07 80 FB 50 26 50
- That happened in both runs, before the
2Ffollow-up frame was even sent. - After that:
- exact
07 C0 2F 95 09 2Eproduced only heartbeat - host-shaped
00 00 2F 95 09 E9also produced only heartbeat
- exact
- Group 2 was heartbeat-only in both tests.
Observed group-1 shape:
| Step | Exact-echo run | Host-mirror run |
|---|---|---|
00 00 EC 40 30 C6 |
07 80 FB 50 26 50 x2 |
07 80 FB 50 26 50 x3 |
07 80 7B 50 26 D0 |
heartbeat only | heartbeat only |
2F follow-up |
heartbeat only | heartbeat only |
Interpretation:
- We did not get a reproducible chained reply to the
2Fstage. - The more important finding is that the
ECbranch itself is context-sensitive and can emit at least two sibling downstream families:07 80 7B 50 26 D007 80 FB 50 26 50
- That makes the
ECbranch look more like a selector into a family space than a strict linear ladder. 07 C0 2F 95 09 2Eis still real from the earlier run, but these follow-ups did not confirm it as the next stable step in an ongoing exchange.
Best current model:
- We are getting closer to a structured understanding of the RCP:
certain host-side
Exvalues reliably push it into specific response families. - But we are not yet at a stable "conversation" where the panel is clearly accepting our last reply and moving to the next deterministic turn.
- Right now the strongest evidence is for:
- selector-like host entries (
E8,E9,EC) - family-specific downstream responses (
7A,7B,FB) - occasional exact-echo sensitivity on some branches
- but not a fully reproducible multi-turn protocol ladder yet
- selector-like host entries (
HE20: EC Timing / Context Split
Try to separate whether EC chooses 7B vs FB because of timing around the
selector step, or because of the deeper branch context.
HE20a: EC With Shorter Spacing
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 A0 00 80 7A" --frame "00 00 EC 40 30 C6" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.10 --read-after-frame 0.25 --read-after-group 0.8 --log captures/rcp-heartbeat-ec-short-spacing.txt
HE20b: EC With Longer Spacing
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 A0 00 80 7A" --frame "00 00 EC 40 30 C6" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.35 --read-after-frame 0.35 --read-after-group 0.8 --log captures/rcp-heartbeat-ec-long-spacing.txt
HE20c: EC Without Leading A0
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 EC 40 30 C6" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-heartbeat-ec-no-a0.txt
What would count as a hit:
- one setup consistently yielding
07 80 7B 50 26 D0 - another setup consistently yielding
07 80 FB 50 26 50 - evidence that leading
A0is part of the selector context rather than just a neutral primer
HE21: Exact Echo Of 07 80 FB 50 26 50
If FB is a real sibling branch, exact echoing it may show whether it behaves
more like 7B or like the inert 7A families.
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 A0 00 80 7A" --frame "00 00 EC 40 30 C6" --frame "07 80 FB 50 26 50" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-heartbeat-echo-exact-fb502650.txt
HE22: Host-Shaped Mirror Of 07 80 FB 50 26 50
Host-shaped checksum for 00 00 FB 50 26 ?? is D7.
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 A0 00 80 7A" --frame "00 00 EC 40 30 C6" --frame "00 00 FB 50 26 D7" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-heartbeat-echo-host-fb5026.txt
What would count as a hit:
- any non-heartbeat response after exact or host-shaped
FB - crossover from
FBinto2F,7B, or another fresh family - evidence that
FBis a meaningful downstream branch rather than just a selector-side variant
2026-05-13 EC Timing And FB Result
Captures:
captures/rcp-heartbeat-ec-short-spacing.txtcaptures/rcp-heartbeat-ec-long-spacing.txtcaptures/rcp-heartbeat-ec-no-a0.txtcaptures/rcp-heartbeat-echo-exact-fb502650.txtcaptures/rcp-heartbeat-echo-host-fb5026.txt
HE20: Timing / Context Split
Observed outcomes:
| Setup | Group-1 result |
|---|---|
short spacing (0.10 s) |
07 80 7B 50 26 D0 |
long spacing (0.35 s) |
07 80 7B 50 26 D0 |
no leading A0 |
07 80 C0 40 30 6D |
Interpretation:
- The
A0lead-in matters a lot for theECbranch. - With
A0present, both short and long spacing still favored07 80 7B 50 26 D0. - Without
A0,ECcollapsed back into the known heartbeat-family transient07 80 C0 40 30 6D. - So the best current read is that
A0is part of the selector context for theEC -> 7B/FBfamily space, not just a neutral primer. - Timing still may matter for
7BvsFB, but this batch says context matters more strongly than spacing in the tested range.
HE21 / HE22: FB Echo Handling
Observed outcomes:
| Setup | Group-1 result |
|---|---|
exact 07 80 FB 50 26 50 |
EC again produced 07 80 7B 50 26 D0; exact FB echo produced no new family |
host-shaped 00 00 FB 50 26 D7 |
EC produced 07 80 7B 50 26 D0; host-shaped FB mirror produced no new family |
Interpretation:
FBdid not behave like a meaningful next-turn reply target.- Both exact and host-shaped
FBhandling fell flat after theECselector produced a7Bresponse in these runs. - That weakens the idea that
FBis a stable downstream branch command. It now looks more like a sibling family observation that can appear on theECbranch, but not something the panel predictably wants answered.
Best current EC model:
A0 + ECcan open a selector-like family space.- In that family space:
7Bis the most stable downstream response so farFBis real, but less stable and not yet actionable- without
A0,ECfalls back toward heartbeat-family behavior
- This is closer to a controlled state map than where we started, but it is still not a stable multi-turn "conversation" ladder.
HE23: Does A0 Also Context E8 And E9?
The EC branch now strongly suggests that leading A0 is part of branch
selection context rather than just a neutral primer. These tests ask whether the
same is true for E8 and E9.
HE23a: E8 Without Leading A0
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 E8 40 30 C2" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-heartbeat-e8-no-a0.txt
HE23b: E9 Without Leading A0
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 E9 40 30 C3" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-heartbeat-e9-no-a0.txt
HE23c: A0 Then E8 Control Repeat
This is just the known-good comparison run so the no-A0 tests can be read
against a fresh control captured in the same phase of work.
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 A0 00 80 7A" --frame "00 00 E8 40 30 C2" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-heartbeat-e8-with-a0-control.txt
HE23d: A0 Then E9 Control Repeat
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 A0 00 80 7A" --frame "00 00 E9 40 30 C3" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-heartbeat-e9-with-a0-control.txt
What would count as a hit:
E8orE9withoutA0still producing their known branches:07 80 7A 50 26 D107 80 7A 28 D3 5C
E8orE9withoutA0collapsing into heartbeat-family transients like07 80 40 40 30 EDor07 80 C0 40 30 6D- a clear difference between no-
A0and with-A0controls that would promoteA0from "possible primer" to "general selector context"
2026-05-13 A0 Context Test For E8 / E9
Captures:
captures/rcp-heartbeat-e8-no-a0.txtcaptures/rcp-heartbeat-e9-no-a0.txtcaptures/rcp-heartbeat-e8-with-a0-control.txtcaptures/rcp-heartbeat-e9-with-a0-control.txt
Observed outcomes:
| Setup | Group-1 result |
|---|---|
E8 without A0 |
later heartbeat provoked 07 80 40 40 30 ED |
E9 without A0 |
later heartbeat provoked 07 80 40 40 30 ED |
A0 -> E8 control |
07 80 7A 50 26 D1 |
A0 -> E9 control |
heartbeat only in this repeat |
Interpretation:
E8now clearly matches theECpattern in one important way: without leadingA0, it falls back into heartbeat-family behavior instead of opening its7Abranch.E9withoutA0also fell back to the same heartbeat-family transient07 80 40 40 30 ED.- So
A0is now more plausibly a broader selector-context opener, not just anEC-specific quirk. - However,
A0is not sufficient to make every selector deterministic: theA0 -> E9control repeat produced only heartbeat in this run, even though earlierA0 -> E9work did produce07 80 7A 28 D3 5C.
Best current read:
A0looks necessary or at least strongly supportive for entering theE8andECfamily spaces.E9remains more timing- or state-sensitive thanE8;A0helps define the context, but does not guarantee the7A 28 D3branch on every clean repeat.- This strengthens the state-map model:
- no
A0-> selector values tend to collapse into heartbeat-family transients - with
A0-> some selector values can open structured family spaces
- no
HE24: Can Something Other Than A0 Open The Ex Selector Surface?
Goal:
- Determine whether
A0is the main gate into theE8/E9/ECselector surface, or whether other known meaningful host frames can provide similar context.
Strategy:
- Keep the selector fixed.
- Change only the leading context frame.
- Use a small set of context candidates that have already shown real protocol
significance elsewhere:
00 00 A0 00 80 7Aas the known-good context00 00 90 00 80 4Abecause90has previously behaved like setup/context00 00 AF 00 80 75becauseAFhas produced structured responses in other sequences- bare heartbeat
00 00 00 00 80 DAas a minimal host-present control
What would count as a hit:
- a non-
A0context causingE8,E9, orECto open the same structured branch we normally associate withA0 - a non-
A0context causing a different but stable structured family - all non-
A0contexts collapsing to heartbeat-family transients, which would makeA0look much more like the main gate
HE24a: 90 As Context For E8
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 00 80 4A" --frame "00 00 E8 40 30 C2" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-context-90-e8.txt
HE24b: 90 As Context For E9
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 00 80 4A" --frame "00 00 E9 40 30 C3" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-context-90-e9.txt
HE24c: 90 As Context For EC
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 00 80 4A" --frame "00 00 EC 40 30 C6" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-context-90-ec.txt
HE24d: AF As Context For E8
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 AF 00 80 75" --frame "00 00 E8 40 30 C2" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-context-af-e8.txt
HE24e: AF As Context For E9
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 AF 00 80 75" --frame "00 00 E9 40 30 C3" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-context-af-e9.txt
HE24f: AF As Context For EC
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 AF 00 80 75" --frame "00 00 EC 40 30 C6" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-context-af-ec.txt
HE24g: Bare Heartbeat Context For E8
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 00 E8 40 30 C2" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-context-hb-e8.txt
HE24h: Bare Heartbeat Context For E9
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 00 E9 40 30 C3" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-context-hb-e9.txt
HE24i: Bare Heartbeat Context For EC
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 00 00 80 DA" --frame "00 00 EC 40 30 C6" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-context-hb-ec.txt
Recommended run order:
HE24c(90 -> EC)HE24f(AF -> EC)HE24i(heartbeat ->EC)HE24a/HE24b(90 -> E8/E9)HE24d/HE24e(AF -> E8/E9)HE24g/HE24h(heartbeat ->E8/E9)
That order keeps the most stateful selector (EC) first, which should tell us
quickly whether A0 is special or whether there is a broader family of context
openers.
2026-05-13 Non-A0 Context Ladder Result
Captures:
captures/rcp-context-90-e8.txtcaptures/rcp-context-90-e9.txtcaptures/rcp-context-90-ec.txtcaptures/rcp-context-af-e8.txtcaptures/rcp-context-af-e9.txtcaptures/rcp-context-af-ec.txtcaptures/rcp-context-hb-e8.txtcaptures/rcp-context-hb-e9.txtcaptures/rcp-context-hb-ec.txt
Observed group-1 outcomes:
| Context -> selector | Result |
|---|---|
90 -> E8 |
07 80 7A 50 26 D1 |
90 -> E9 |
07 80 7A 28 D3 5C |
90 -> EC |
07 80 7B 50 26 D0 |
AF -> E8 |
07 80 FA 50 26 51 |
AF -> E9 |
07 80 7A 28 D3 5C |
AF -> EC |
07 80 7B 50 26 D0 |
heartbeat -> E8 |
07 80 7A 50 26 D1 |
heartbeat -> E9 |
07 80 7A 28 D3 5C |
heartbeat -> EC |
no 7B; initial heartbeat provoked 07 80 40 40 30 ED, then EC stayed heartbeat-only |
Interpretation:
A0is not the only context opener for theExselector surface.90can stand in as a strong general context opener for all three tested selectors:E8->7A 50 26E9->7A 28 D3EC->7B 50 26
AFcan also open meaningful selector branches:AF -> E9matched the knownE9familyAF -> ECmatched the knownECfamilyAF -> E8shifted to the alternate siblingFA 50 26family instead of7A 50 26
- Bare heartbeat is enough context for
E8andE9, but not forEC.ECstill appears stricter and more context-sensitive than theE8/E9branch pair.
Best current read:
- We are not looking at a single hard gate byte.
- We are looking at a broader context-opener family:
A090AF- and, for at least
E8/E9, even bare heartbeat context
E8andE9seem easier to open thanEC.ECmay require a stronger or richer context class than plain heartbeat.AF -> E8 -> FA 50 26is especially interesting because it suggests the context frame can influence which sibling family the selector opens, not just whether it opens anything at all.
HE25: Do 90 And AF Change Downstream Behavior Too?
Goal:
- Check whether
90andAFonly change the first family opened by a selector, or whether they also change what happens when we answer that family.
Method:
- Use a context opener (
90orAF) - Open a known selector branch (
E8,E9, orEC) - Immediately send the exact downstream family frame that branch produced
- Compare whether the follow-up behavior differs by opener
This keeps the selector and downstream family fixed while changing only the context opener.
What would count as a hit:
- the same downstream exact echo behaving differently under
90vsAF - one opener causing a new second-stage family while the other falls flat
- the opener changing whether the branch drains to heartbeat or continues
HE25a: 90 -> E8 -> exact 7A 50 26
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 00 80 4A" --frame "00 00 E8 40 30 C2" --frame "07 80 7A 50 26 D1" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-context-90-e8-exact-7a5026.txt
HE25b: AF -> E8 -> exact FA 50 26
This uses the family that AF -> E8 actually opened.
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 AF 00 80 75" --frame "00 00 E8 40 30 C2" --frame "07 80 FA 50 26 51" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-context-af-e8-exact-fa5026.txt
HE25c: 90 -> E9 -> exact 7A 28 D3
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 00 80 4A" --frame "00 00 E9 40 30 C3" --frame "07 80 7A 28 D3 5C" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-context-90-e9-exact-7a28d3.txt
HE25d: AF -> E9 -> exact 7A 28 D3
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 AF 00 80 75" --frame "00 00 E9 40 30 C3" --frame "07 80 7A 28 D3 5C" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-context-af-e9-exact-7a28d3.txt
HE25e: 90 -> EC -> exact 7B 50 26
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 00 80 4A" --frame "00 00 EC 40 30 C6" --frame "07 80 7B 50 26 D0" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-context-90-ec-exact-7b5026.txt
HE25f: AF -> EC -> exact 7B 50 26
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 AF 00 80 75" --frame "00 00 EC 40 30 C6" --frame "07 80 7B 50 26 D0" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-context-af-ec-exact-7b5026.txt
Recommended order:
HE25e(90 -> EC -> exact 7B)HE25f(AF -> EC -> exact 7B)HE25c/HE25d(90/AF -> E9 -> exact 7A 28 D3)HE25a/HE25b(90 -> E8 -> exact 7A 50 26,AF -> E8 -> exact FA 50 26)
That order keeps the most stateful selector first again, while still checking
whether opener choice changes the downstream echo behavior on the simpler E8
and E9 branches.
2026-05-13 Opener-Dependent Downstream Behavior Result
Captures:
captures/rcp-context-90-e8-exact-7a5026.txtcaptures/rcp-context-af-e8-exact-fa5026.txtcaptures/rcp-context-90-e9-exact-7a28d3.txtcaptures/rcp-context-af-e9-exact-7a28d3.txtcaptures/rcp-context-90-ec-exact-7b5026.txtcaptures/rcp-context-af-ec-exact-7b5026.txt
Observed group-1 outcomes:
| Setup | Selector result | Exact-echo follow-up result |
|---|---|---|
90 -> E8 -> exact 7A 50 26 |
07 80 7A 58 26 D9 |
heartbeat only after sending 07 80 7A 50 26 D1 |
AF -> E8 -> exact FA 50 26 |
07 80 7A 50 26 D1 |
heartbeat only after sending 07 80 FA 50 26 51 |
90 -> E9 -> exact 7A 28 D3 |
07 80 7A 28 D3 5C |
heartbeat only |
AF -> E9 -> exact 7A 28 D3 |
07 80 7A 28 D3 5C |
heartbeat only |
90 -> EC -> exact 7B 50 26 |
07 80 FB 50 26 50 |
heartbeat only after sending 07 80 7B 50 26 D0 |
AF -> EC -> exact 7B 50 26 |
07 80 7B 50 26 D0 |
heartbeat only |
Interpretation:
- No opener produced a stable second-stage reply to the downstream exact echo.
- So, for now, opener choice seems to affect the branch entry much more than the reply-to-the-branch behavior.
- But opener choice definitely matters at the selector result level:
90 -> E8shifted the response from the familiar7A 50 26family to the sibling7A 58 26 D990 -> ECshifted the response from7B 50 26 D0to the siblingFB 50 26 50AF -> ECpreserved the7B 50 26 D0branch
E9looks more stable across openers thanE8andEC: both90andAFstill opened07 80 7A 28 D3 5C
Most important takeaway:
- opener bytes are not just yes/no "permissions" for the selector surface
- they can change which sibling family a selector lands in
- but once that family appears, echoing the expected downstream frame still did not create a reproducible next turn
Best current model:
- context opener selects or biases a family page
- selector byte chooses within that opened space
- downstream family frames still look more like readable responses than clear host prompts
Best next move:
- when a selector result shifts under a different opener, answer the actually observed downstream frame instead of the previously known sibling frame
- the strongest immediate candidates are:
90 -> E8 -> exact 07 80 7A 58 26 D990 -> EC -> exact 07 80 FB 50 26 50
HE26: Answer The Actually Observed 90-Shifted Family
Goal:
- Now that
90is clearly able to shift the family/page opened byE8andEC, answer the observed downstream frame rather than the older sibling family we expected from earlier runs.
Hypothesis:
- If opener choice is selecting a page or family, the correct next probe is the exact frame from that page, not a nearby family member learned under another opener.
What would count as a hit:
- any fresh non-heartbeat family after the exact observed-frame echo
- a reproducible second-stage branch that only appears when the echoed frame matches the opener-selected family
- visible evidence that page-matched echoing behaves differently from sibling-mismatched echoing
HE26a: 90 -> E8 -> exact 7A 58 26
Under 90, E8 produced 07 80 7A 58 26 D9, so answer that exact frame.
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 00 80 4A" --frame "00 00 E8 40 30 C2" --frame "07 80 7A 58 26 D9" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-context-90-e8-exact-7a5826.txt
HE26b: 90 -> EC -> exact FB 50 26
Under 90, EC produced 07 80 FB 50 26 50, so answer that exact frame.
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 00 80 4A" --frame "00 00 EC 40 30 C6" --frame "07 80 FB 50 26 50" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-context-90-ec-exact-fb5026.txt
Recommended order:
HE26b(90 -> EC -> exact FB 50 26)HE26a(90 -> E8 -> exact 7A 58 26)
EC still looks like the more stateful branch, so it has the better chance of
showing whether page-matched echoing matters.
2026-05-13 Page-Matched Echo Result
Captures:
captures/rcp-context-90-e8-exact-7a5826.txtcaptures/rcp-context-90-ec-exact-fb5026.txt
Observed outcomes:
| Setup | Selector result | Page-matched exact echo result |
|---|---|---|
90 -> E8 -> exact 7A 58 26 |
actual run produced 07 80 7A 50 26 D1 |
sending 07 80 7A 58 26 D9 did not open a new family; the queued 7A 50 26 D1 drained, then heartbeat |
90 -> EC -> exact FB 50 26 |
07 80 FB 50 26 50 |
sending 07 80 FB 50 26 50 did not open a new family; then heartbeat |
Interpretation:
- Page-matched echoing still did not create a stable second-stage exchange.
- For
EC, this is fairly clean: the observedFB 50 26family was echoed back exactly and the branch still collapsed to heartbeat. - For
E8, the run is interesting in a different way:- the earlier
90 -> E8test had produced sibling07 80 7A 58 26 D9 - this repeat instead produced
07 80 7A 50 26 D1 - sending the page-matched
7A 58 26 D9frame did not redirect or extend the branch; the observed7A 50 26 D1simply drained out
- the earlier
- So the strongest conclusion is still: opener choice clearly biases the family/page the selector lands in, but the downstream family frames still do not behave like obvious prompts the host is expected to answer.
Best current read:
- We are getting better at steering the RCP into specific family spaces.
- We are not yet seeing evidence that matching the page family in our reply is enough to advance to a deterministic next turn.
- That keeps the focus on:
- context opener
- selector
- family chosen rather than on any confirmed reply ladder after the family appears.
HE27: Host State/Value Probing Ladder
Goal:
- Test whether the hidden rule lives in the opener
state/valuebytes, the selectorstate/valuebytes, or both. - Keep the structure disciplined:
- vary opener
state/valuewith selector fixed - vary selector
state/valuewith opener fixed
- vary opener
This is the first intentionally broad state/value ladder aimed at the selector-surface model, rather than raw command discovery.
What would count as a hit:
- a state/value change shifting the opened family while command bytes stay fixed
- one state/value pair acting like a stronger opener than another
- a selector state/value pair opening a family that the baseline selector does not
- repeated collapse to the same family regardless of state/value, which would tell us that the command byte matters more than those fields on that branch
Tier 1: Opener State/Value Sweep With Fixed Selectors
Use the same selector each time and vary only the opener payload.
State/value variants:
- opener baseline:
00 80 - opener alt 1:
20 D0 - opener alt 2:
40 30 - opener alt 3:
60 30
Checksums:
90 00 80->00 00 90 00 80 4A90 20 D0->00 00 90 20 D0 3A90 40 30->00 00 90 40 30 BA90 60 30->00 00 90 60 30 9AAF 00 80->00 00 AF 00 80 75AF 20 D0->00 00 AF 20 D0 05AF 40 30->00 00 AF 40 30 85AF 60 30->00 00 AF 60 30 A5
HE27a: 90 payload sweep into E8
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 00 80 4A" --frame "00 00 E8 40 30 C2" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-statevalue-90-e8-0080.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 20 D0 3A" --frame "00 00 E8 40 30 C2" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-statevalue-90-e8-20d0.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 40 30 BA" --frame "00 00 E8 40 30 C2" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-statevalue-90-e8-4030.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 60 30 9A" --frame "00 00 E8 40 30 C2" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-statevalue-90-e8-6030.txt
HE27b: 90 payload sweep into EC
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 00 80 4A" --frame "00 00 EC 40 30 C6" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-statevalue-90-ec-0080.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 20 D0 3A" --frame "00 00 EC 40 30 C6" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-statevalue-90-ec-20d0.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 40 30 BA" --frame "00 00 EC 40 30 C6" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-statevalue-90-ec-4030.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 60 30 9A" --frame "00 00 EC 40 30 C6" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-statevalue-90-ec-6030.txt
HE27c: AF payload sweep into E8
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 AF 00 80 75" --frame "00 00 E8 40 30 C2" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-statevalue-af-e8-0080.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 AF 20 D0 05" --frame "00 00 E8 40 30 C2" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-statevalue-af-e8-20d0.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 AF 40 30 85" --frame "00 00 E8 40 30 C2" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-statevalue-af-e8-4030.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 AF 60 30 A5" --frame "00 00 E8 40 30 C2" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-statevalue-af-e8-6030.txt
HE27d: AF payload sweep into EC
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 AF 00 80 75" --frame "00 00 EC 40 30 C6" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-statevalue-af-ec-0080.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 AF 20 D0 05" --frame "00 00 EC 40 30 C6" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-statevalue-af-ec-20d0.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 AF 40 30 85" --frame "00 00 EC 40 30 C6" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-statevalue-af-ec-4030.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 AF 60 30 A5" --frame "00 00 EC 40 30 C6" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-statevalue-af-ec-6030.txt
Tier 2: Selector State/Value Sweep With Fixed Openers
Now hold the opener steady and vary only selector state/value.
Selector checksums:
E8 00 80->00 00 E8 00 80 32E8 20 D0->00 00 E8 20 D0 42E8 40 30->00 00 E8 40 30 C2E8 60 30->00 00 E8 60 30 E2E9 00 80->00 00 E9 00 80 33E9 20 D0->00 00 E9 20 D0 43E9 40 30->00 00 E9 40 30 C3E9 60 30->00 00 E9 60 30 E3EC 00 80->00 00 EC 00 80 36EC 20 D0->00 00 EC 20 D0 46EC 40 30->00 00 EC 40 30 C6EC 60 30->00 00 EC 60 30 E6
HE27e: 90 opener with selector payload sweep on E8
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 00 80 4A" --frame "00 00 E8 00 80 32" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-statevalue-sel-e8-0080.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 00 80 4A" --frame "00 00 E8 20 D0 42" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-statevalue-sel-e8-20d0.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 00 80 4A" --frame "00 00 E8 40 30 C2" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-statevalue-sel-e8-4030.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 00 80 4A" --frame "00 00 E8 60 30 E2" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-statevalue-sel-e8-6030.txt
HE27f: 90 opener with selector payload sweep on E9
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 00 80 4A" --frame "00 00 E9 00 80 33" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-statevalue-sel-e9-0080.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 00 80 4A" --frame "00 00 E9 20 D0 43" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-statevalue-sel-e9-20d0.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 00 80 4A" --frame "00 00 E9 40 30 C3" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-statevalue-sel-e9-4030.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 00 80 4A" --frame "00 00 E9 60 30 E3" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-statevalue-sel-e9-6030.txt
HE27g: 90 opener with selector payload sweep on EC
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 00 80 4A" --frame "00 00 EC 00 80 36" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-statevalue-sel-ec-0080.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 00 80 4A" --frame "00 00 EC 20 D0 46" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-statevalue-sel-ec-20d0.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 00 80 4A" --frame "00 00 EC 40 30 C6" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-statevalue-sel-ec-4030.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 00 80 4A" --frame "00 00 EC 60 30 E6" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-statevalue-sel-ec-6030.txt
Recommended order:
HE27b(90payload sweep intoEC)HE27d(AFpayload sweep intoEC)HE27g(90opener with selector payload sweep onEC)HE27a(90payload sweep intoE8)HE27c(AFpayload sweep intoE8)HE27e/HE27f(90opener with selector payload sweep onE8/E9)
That keeps the most stateful branch (EC) in front while still giving us a
comprehensive way to separate opener payload effects from selector payload
effects.
2026-05-13 State/Value Probing Ladder Result
This ladder gave the clearest evidence so far that the state/value bytes are
meaningful and can steer family selection.
Tier 1: Opener Payload Sweep
90 opener into E8
| Opener payload | Result |
|---|---|
90 00 80 |
07 80 7A 50 26 D1 |
90 20 D0 |
07 80 7A 50 26 D1 |
90 40 30 |
07 80 7A 50 26 D1 |
90 60 30 |
07 80 FA 50 26 51 |
Read:
90opener payload is meaningful onE8.60 30flips the branch from7A 50 26into siblingFA 50 26.
90 opener into EC
| Opener payload | Result |
|---|---|
90 00 80 |
07 80 7B 58 26 D8 |
90 20 D0 |
07 80 FB 50 26 50 |
90 40 30 |
07 80 7B 50 26 D0 |
90 60 30 |
07 80 7B 50 26 D0 |
Read:
90opener payload clearly changes which sibling family/pageECopens.00 80gives a shifted7B 58 26variant.20 D0flips toFB 50 26.40 30and60 30both land on7B 50 26.
AF opener into E8
| Opener payload | Result |
|---|---|
AF 00 80 |
07 80 7A 50 26 D1 |
AF 20 D0 |
07 80 C0 40 30 6D |
AF 40 30 |
07 80 7A 50 26 D1 |
AF 60 30 |
07 80 40 40 30 ED |
Read:
AFopener payload can either preserve theE8 -> 7Abranch or collapse it back into heartbeat-family transients.20 D0and60 30appear hostile or misdirecting on this branch.
AF opener into EC
| Opener payload | Result |
|---|---|
AF 00 80 |
07 80 FB 50 26 50 |
AF 20 D0 |
later heartbeat-family 07 80 40 40 30 ED |
AF 40 30 |
later heartbeat-family 07 80 40 40 30 ED |
AF 60 30 |
later heartbeat-family 07 80 40 40 30 ED |
Read:
AFopener payload is even more selective onEC.- Only the baseline
00 80payload opened a structured family. 20 D0,40 30, and60 30all collapsed into heartbeat-family behavior.
Tier 2: Selector Payload Sweep Under Fixed 90 00 80
E8 selector payload
| Selector payload | Result |
|---|---|
E8 00 80 |
07 80 7A 40 30 D7 |
E8 20 D0 |
07 80 7A 48 3A D5 |
E8 40 30 |
07 80 7A 50 26 D1 |
E8 60 30 |
07 80 7A 58 26 D9 |
E9 selector payload
| Selector payload | Result |
|---|---|
E9 00 80 |
07 80 7A 20 D8 5F |
E9 20 D0 |
07 80 7A 24 FD 7E |
E9 40 30 |
07 80 7A 28 D3 5C |
E9 60 30 |
07 80 7A 2C D3 58 |
EC selector payload
| Selector payload | Result |
|---|---|
EC 00 80 |
07 80 FB 40 30 56 |
EC 20 D0 |
07 80 E4 40 30 49 |
EC 40 30 |
07 80 FB 50 26 50 |
EC 60 30 |
07 80 7B 58 26 D8 |
Interpretation:
- Selector
state/valuebytes are strongly meaningful. - On
E8andE9, the response family byte stayed at7A, while the following bytes changed systematically with selector payload. - On
EC, selector payload changes were even stronger: the family itself shifted amongFB,E4, and7B. - This is the best current evidence that:
- command byte picks a broad selector region
state/valuebytes pick a page, subtype, or data class within that region
Best current model after HE27:
- opener command matters
- opener payload matters
- selector command matters
- selector payload matters
- the protocol surface is more parameterized than we first thought
- but we still do not have a stable proof that the downstream family frames are host prompts rather than readable response blocks
HE28: Off-Grid Pair Test
Goal:
- Test whether the two payload bytes behave more like an accepted pair code than two semantically independent fields.
Idea:
- We already know these combinations are meaningful on several branches:
00 8020 D040 3060 30
- Now try mixed combinations that were not part of the known-good set:
00 3020 3040 D060 80
What would count as a hit:
- mixed pairs behaving just like nearby known-good pairs, which would support more independent byte meanings
- mixed pairs mostly collapsing to heartbeat/transients or producing odd outliers, which would support the "2-byte code" model
- one branch accepting mixed pairs while another rejects them, which would mean pairing rules are selector-specific
Checksums:
E8 00 30->00 00 E8 00 30 82E8 20 30->00 00 E8 20 30 A2E8 40 D0->00 00 E8 40 D0 22E8 60 80->00 00 E8 60 80 52E9 00 30->00 00 E9 00 30 83E9 20 30->00 00 E9 20 30 A3E9 40 D0->00 00 E9 40 D0 23E9 60 80->00 00 E9 60 80 53EC 00 30->00 00 EC 00 30 86EC 20 30->00 00 EC 20 30 A6EC 40 D0->00 00 EC 40 D0 26EC 60 80->00 00 EC 60 80 56
Keep the opener fixed to the strongest baseline opener for each local map:
- use
90 00 80beforeE8,E9, andEC
HE28a: Off-grid selector pairs on E8
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 00 80 4A" --frame "00 00 E8 00 30 82" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-pairtest-e8-0030.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 00 80 4A" --frame "00 00 E8 20 30 A2" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-pairtest-e8-2030.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 00 80 4A" --frame "00 00 E8 40 D0 22" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-pairtest-e8-40d0.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 00 80 4A" --frame "00 00 E8 60 80 52" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-pairtest-e8-6080.txt
HE28b: Off-grid selector pairs on E9
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 00 80 4A" --frame "00 00 E9 00 30 83" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-pairtest-e9-0030.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 00 80 4A" --frame "00 00 E9 20 30 A3" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-pairtest-e9-2030.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 00 80 4A" --frame "00 00 E9 40 D0 23" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-pairtest-e9-40d0.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 00 80 4A" --frame "00 00 E9 60 80 53" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-pairtest-e9-6080.txt
HE28c: Off-grid selector pairs on EC
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 00 80 4A" --frame "00 00 EC 00 30 86" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-pairtest-ec-0030.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 00 80 4A" --frame "00 00 EC 20 30 A6" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-pairtest-ec-2030.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 00 80 4A" --frame "00 00 EC 40 D0 26" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-pairtest-ec-40d0.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --frame "00 00 90 00 80 4A" --frame "00 00 EC 60 80 56" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-pairtest-ec-6080.txt
Recommended order:
HE28c(ECoff-grid pairs)HE28a(E8off-grid pairs)HE28b(E9off-grid pairs)
That keeps the most expressive selector first, where the pair-code hypothesis is most likely to show itself clearly.
2026-05-13 Off-Grid Pair Result
This ladder weakens the strict "only a few accepted 2-byte pair codes" model.
E8 off-grid pairs under 90 00 80
| Selector payload | Result |
|---|---|
E8 00 30 |
07 80 7A 40 26 C1 |
E8 20 30 |
07 80 FA 48 26 49 |
E8 40 D0 |
07 80 7A 50 3A CD |
E8 60 80 |
07 80 7A 58 30 CF |
E9 off-grid pairs under 90 00 80
| Selector payload | Result |
|---|---|
E9 00 30 |
07 80 7A 20 D3 54 |
E9 20 30 |
07 80 7A 24 D3 50 |
E9 40 D0 |
07 80 7A 28 DD 52 |
E9 60 80 |
07 80 7A 2C D8 53 |
EC off-grid pairs under 90 00 80
| Selector payload | Result |
|---|---|
EC 00 30 |
07 80 7B 40 26 C0 |
EC 20 30 |
07 80 7B 4C 26 CC |
EC 40 D0 |
07 80 FB 50 3A 4C |
EC 60 80 |
07 80 7B 58 30 CE |
Interpretation:
- The RCP did not reject the off-grid mixed combinations.
- Instead, it returned structured, checksum-valid sibling families in a highly systematic way.
- That makes the strongest current model:
- these are still two separate bytes on the wire
- and their meanings appear at least partly compositional, not just a small fixed whitelist of accepted pair codes
- In other words, the "strict 2-byte enum only" hypothesis is weaker now.
- A more likely model is:
- selector command chooses a region
- first payload byte strongly influences one axis/page
- second payload byte also influences the returned subtype/data bytes
- some selectors, especially
EC, can still flip whole sibling families (7BvsFB) depending on the combination
Best current takeaway:
- the
state/valuebytes are meaningful - they are not behaving like arbitrary filler
- but they also are not behaving like only four hardcoded legal pair tokens
- they look more like a small 2-byte parameter space with selector-specific mapping rules
HE29: Valid-Connection / Camera-Info Stream Fan-Out
Goal:
- Fan back out from one-shot reads and selector branches into sustained host-present plus camera-info-like traffic.
- Try to answer a more practical question:
can we send a stream that the panel treats as a real CCU/camera connection,
even if only enough to change
CONNECT NOT ACT, light a lamp, or wake a readout?
Working idea:
- Plain host heartbeat can hold the panel out of
CONNECT NOT ACTwhile it is flowing, but it does not by itself produce a stable active session. - The panel may want both:
- ongoing host presence/cadence
- and a rotating set of camera/capability/status pages
- We now have several families that are plausible candidates for those pages:
- discovery surface:
A0,B0,B5 - selector surface:
90 -> E8/E9/EC - host-shaped family mirrors:
7A,7B,FB - heartbeat-adjacent base families:
40,C0,50
- discovery surface:
What would count as a hit:
- the panel stays out of
CONNECT NOT ACTand- a light changes
- a numeric readout changes
- the LCD changes to something new
- or one-shot branches become reusable while the stream is running
- repeated non-heartbeat RX beyond the usual single group-1 burst
- any sign that the panel begins acting "session alive" rather than merely "host present"
Note:
serial_sequence_probe.pynow supports--prompt-screen, so the final screen/light observation can live in the same capture log.
Checksums already known:
- heartbeat:
00 00 00 00 80 DA A0:00 00 A0 00 80 7AB0:00 00 B0 00 80 6AB5:00 00 B5 00 80 6F90:00 00 90 00 80 4AAF:00 00 AF 00 80 75E8 40 30:00 00 E8 40 30 C2E9 40 30:00 00 E9 40 30 C3EC 40 30:00 00 EC 40 30 C6- host
7A 50 26:00 00 7A 50 26 56 - host
7A 28 D3:00 00 7A 28 D3 DB - host
7B 50 26:00 00 7B 50 26 57 - host
FB 50 26:00 00 FB 50 26 D7 - host
FA 50 26:00 00 FA 50 26 D6 - host
40 40 30:00 00 40 40 30 6A - host
C0 40 30:00 00 C0 40 30 EA - host
50 40 30:00 00 50 40 30 7A
HE29a: Discovery carousel under maintained heartbeat
Hypothesis:
- The panel may want periodic readable capability/status pages, not just a lone one-shot query at boot.
python scripts/serial_sequence_probe.py --port COM5 --prompt --prompt-screen --pre-read 1.0 --frame "00 00 00 00 80 DA" --frame "00 00 A0 00 80 7A" --frame "00 00 00 00 80 DA" --frame "00 00 B0 00 80 6A" --frame "00 00 00 00 80 DA" --frame "00 00 B5 00 80 6F" --repeat 10 --frame-interval 0.12 --read-after-frame 0.06 --repeat-interval 0.15 --read-after-group 0.20 --log captures/rcp-session-fanout-discovery-carousel.txt
Watch for:
- later groups reopening
68,6C, or6Dfamilies - the panel leaving
CONNECT NOT ACTwhile the carousel runs - any lamp or readout change
HE29b: Selector-page carousel under strong 90 context
Hypothesis:
- The selector surface may actually be a rotating camera-info page set, and the panel may want repeated page selection rather than isolated one-shot use.
python scripts/serial_sequence_probe.py --port COM5 --prompt --prompt-screen --pre-read 1.0 --frame "00 00 90 00 80 4A" --frame "00 00 E8 40 30 C2" --frame "00 00 00 00 80 DA" --frame "00 00 90 00 80 4A" --frame "00 00 E9 40 30 C3" --frame "00 00 00 00 80 DA" --frame "00 00 90 00 80 4A" --frame "00 00 EC 40 30 C6" --repeat 8 --frame-interval 0.12 --read-after-frame 0.06 --repeat-interval 0.15 --read-after-group 0.20 --log captures/rcp-session-fanout-selector-carousel.txt
Watch for:
- later groups still opening
7A,7B,FB, orFAfamilies - the selector space becoming reusable instead of draining to heartbeat
- any visible wake-up on the panel
HE29c: Direct host-shaped family feed
Hypothesis:
- The panel may want host-origin camera-state frames that look more like the downstream family blocks than like discovery queries.
python scripts/serial_sequence_probe.py --port COM5 --prompt --prompt-screen --pre-read 1.0 --frame "00 00 00 00 80 DA" --frame "00 00 7A 50 26 56" --frame "00 00 00 00 80 DA" --frame "00 00 7A 28 D3 DB" --frame "00 00 00 00 80 DA" --frame "00 00 7B 50 26 57" --frame "00 00 00 00 80 DA" --frame "00 00 FB 50 26 D7" --repeat 10 --frame-interval 0.12 --read-after-frame 0.06 --repeat-interval 0.15 --read-after-group 0.20 --log captures/rcp-session-fanout-direct-family-feed.txt
Watch for:
- any visible panel reaction with no preceding opener/selector steps
- whether any of these host-shaped family blocks seem to act like camera values
- whether the panel begins sending a different recurring status frame
HE29d: Hybrid select-then-feed stream
Hypothesis:
- The panel may want a selector/page choice immediately followed by page data, not just a readback-like query.
python scripts/serial_sequence_probe.py --port COM5 --prompt --prompt-screen --pre-read 1.0 --frame "00 00 90 00 80 4A" --frame "00 00 E8 40 30 C2" --frame "00 00 7A 50 26 56" --frame "00 00 00 00 80 DA" --frame "00 00 90 00 80 4A" --frame "00 00 E9 40 30 C3" --frame "00 00 7A 28 D3 DB" --frame "00 00 00 00 80 DA" --frame "00 00 90 00 80 4A" --frame "00 00 EC 40 30 C6" --frame "00 00 7B 50 26 57" --repeat 8 --frame-interval 0.12 --read-after-frame 0.06 --repeat-interval 0.15 --read-after-group 0.20 --log captures/rcp-session-fanout-hybrid-90.txt
Watch for:
- whether later groups stop collapsing after the first selector-family burst
- whether page-matched host data makes the selector space feel more "live"
- any call lamp, tally, or numeric display change
HE29e: AF-biased sibling-family stream
Hypothesis:
AFchanges which sibling family opens; maybe that opener is closer to a real CCU "camera data" context than90for some pages.
python scripts/serial_sequence_probe.py --port COM5 --prompt --prompt-screen --pre-read 1.0 --frame "00 00 AF 00 80 75" --frame "00 00 E8 40 30 C2" --frame "00 00 FA 50 26 D6" --frame "00 00 00 00 80 DA" --frame "00 00 AF 00 80 75" --frame "00 00 EC 40 30 C6" --frame "00 00 7B 50 26 57" --repeat 8 --frame-interval 0.12 --read-after-frame 0.06 --repeat-interval 0.15 --read-after-group 0.20 --log captures/rcp-session-fanout-hybrid-af.txt
Watch for:
- whether
AFkeepsE8in theFAsibling family more reliably - whether
AFchanges visible panel behavior even if serial RX still looks one-shot
HE29f: Heartbeat-family base-status feed
Hypothesis:
- The
40/C0/50families may be a base camera-status layer rather than mere "wrong" answers, and the panel may want them as a background stream.
python scripts/serial_sequence_probe.py --port COM5 --prompt --prompt-screen --pre-read 1.0 --frame "00 00 00 00 80 DA" --frame "00 00 40 40 30 6A" --frame "00 00 00 00 80 DA" --frame "00 00 C0 40 30 EA" --frame "00 00 00 00 80 DA" --frame "00 00 50 40 30 7A" --repeat 10 --frame-interval 0.12 --read-after-frame 0.06 --repeat-interval 0.15 --read-after-group 0.20 --log captures/rcp-session-fanout-base-status.txt
Watch for:
- whether this suppresses
CONNECT NOT ACTmore convincingly than plain heartbeat alone - whether any lamp or readout reacts even if selector-space branches do not
- whether the panel responds with a recurring non-heartbeat family rather than isolated group-1 bursts
Recommended order:
HE29adiscovery carouselHE29dhybrid90select-then-feedHE29cdirect host-shaped family feedHE29fheartbeat-family base-status feedHE29bselector carouselHE29eAF-biased sibling-family stream
Reasoning:
HE29aandHE29dare the two most plausible "real CCU behavior" guesses: periodic readable pages, or page-select plus page-data.HE29casks whether the panel can be fed camera-state blocks directly.HE29fis the slightly weirder but still useful branch: maybe the heartbeat-adjacent40/C0/50families are actually the base layer the panel wants before richer pages make sense.
2026-05-13 HE29 Fan-Out Results
Front-panel result first:
- No tested HE29 stream changed the visible panel state in a useful way.
- No run produced a new LCD state beyond the previously known inactive behavior, and no lamp/readout change was observed.
That said, the wire result was not completely dead.
HE29a: Discovery carousel under maintained heartbeat
Log:
captures/rcp-session-fanout-discovery-carousel.txt
Result:
- The sustained
heartbeat -> A0 -> heartbeat -> B0 -> heartbeat -> B5carousel produced only heartbeat-compatible RX for every group. - None of the older one-shot readable families (
68,6C,6D) reopened under this maintained cycle.
Read:
- Simple repeated discovery-page polling does not look like the missing live session traffic.
- It also did not make the one-shot readable surface reusable.
HE29b: Selector carousel under strong 90 context
Log:
captures/rcp-session-fanout-selector-carousel.txt
Result:
- Group 1,
90 -> E8, produced:07 80 FA 50 26 51
90 -> E9and90 -> ECin the same cycle then stayed heartbeat-only.- Groups 2-8 were heartbeat-only throughout.
Read:
- Repeating selector-page choice in a rotating carousel still does not sustain a richer session.
- The stream appears to spend a single selector-family opening and then collapse back into ordinary heartbeat behavior.
HE29c: Direct host-shaped family feed
Log:
captures/rcp-session-fanout-direct-family-feed.txt
Result:
- Group 1, host-shaped
00 00 7A 50 26 56produced a new RCP family:07 80 2F 95 C9 AE
- After that:
- host-shaped
7A 28 D3produced no structured reply - host-shaped
7B 50 26stayed heartbeat-only - host-shaped
FB 50 26stayed heartbeat-only
- host-shaped
- Later groups did not reproduce the
2F 95 C9family.
Read:
- This is the first HE29 branch where a pure host-shaped family feed produced a genuinely new structured response.
- It still behaved one-shot and did not wake the panel visually.
- So direct family feed is not enough to create a live connection, but it does look protocol-meaningful.
HE29d: Hybrid 90 select-then-feed
Log:
captures/rcp-session-fanout-hybrid-90.txt
Result:
- Group 1:
90 -> E8produced07 80 7A 50 26 D1- immediate host-shaped
7A 50 26feed produced no next stage
- The later
E9andECportions of the same group stayed heartbeat-only. - Groups 2-8 were heartbeat-only throughout.
Read:
- Page-select plus matching host feed still does not turn the selector space into a reusable or "live" stream.
- This weakens the idea that the missing session is simply "select page, then send that page's payload."
HE29e: AF-biased sibling-family stream
Log:
captures/rcp-session-fanout-hybrid-af.txt
Result:
- Group 1:
AF -> E8produced07 80 7A 50 26 D1- host-shaped
FA 50 26feed produced no next stage
- The later
AF -> ECportion stayed heartbeat-only. - Groups 2-8 were heartbeat-only throughout.
Read:
AFdid not behave like a more realistic camera-data opener in this sustained mixed-stream form.- Even the sibling-family-biased branch still collapsed immediately after the first selector-family burst.
HE29f: Heartbeat-family base-status feed
Log:
captures/rcp-session-fanout-base-status.txt
Result:
- Group 1, host-shaped
00 00 40 40 30 6Aproduced a new RCP family:07 80 D0 50 26 7B
- The following host-shaped
C0 40 30and50 40 30frames did not open a new visible stage. - Groups 2-10 were heartbeat-only throughout.
Read:
- This is the second HE29 branch that produced a genuinely new structured family.
- So the
40family is still worth taking seriously as more than a pure "wrong" response bucket. - But, like the
2F 95 C9branch above, it is still one-shot and did not visibly activate the panel.
HE29 Overall Read
What failed:
- No tested sustained stream woke the panel visually.
- No tested stream cleared the broader "not really connected" condition.
- No tested stream made the selector surface reusable in a stable way.
What still matters:
- Two new structured families appeared when we treated the known response
families as host-origin traffic instead of just things to mirror:
00 00 7A 50 26 56->07 80 2F 95 C9 AE00 00 40 40 30 6A->07 80 D0 50 26 7B
- That strengthens the idea that some of these families are not just passive readback blocks; they can still act as meaningful stimuli from the host side.
Best current read after HE29:
- The missing active session still does not look like:
- plain heartbeat
- repeated discovery reads
- repeated selector-page reads
- naive page-select plus matching host feed
- The next smarter branch is probably to stay narrow around the two new
host-stimulated response families (
2F 95 C9andD0 50 26) and test whether they represent a deeper camera/base-status layer rather than just more one-shot siblings.
HE30: Targeted Follow-Up On 2F 95 C9 And D0 50 26
Goal:
- Treat the two new HE29 host-stimulated families as real protocol leads:
07 80 2F 95 C9 AE07 80 D0 50 26 7B
- Work out whether they are:
- simple one-shot siblings
- a deeper base-status layer
- or part of a real next-turn exchange that we have not answered correctly yet
Strategy:
- Reproduce each family cleanly and answer that exact observed family
- Try the host-shaped mirror of the observed family
- Compare the new
2F 95 C9branch to the older2F 95 09branch - Probe nearby host-side trigger siblings to see whether the branch is narrow or family-wide
- Test whether the new family itself works cold after boot, or only as a response branch
Checksums:
- host
2F 95 C9->00 00 2F 95 C9 29 - host
D0 50 26->00 00 D0 50 26 FC - older host
2F 95 09->00 00 2F 95 09 E9 - host
7A 58 26->00 00 7A 58 26 5E - host
7A 50 3A->00 00 7A 50 3A 4A - host
40 60 30->00 00 40 60 30 4A
HE30a: Exact and host-shaped answers to 07 80 2F 95 C9 AE
Hypothesis:
- If
2F 95 C9is a real second-stage family, answering the exact observed frame or its host-shaped mirror may produce a cleaner third step than the old2F 95 09branch did.
python scripts/serial_sequence_probe.py --port COM5 --prompt --prompt-screen --pre-read 1.0 --frame "00 00 00 00 80 DA" --frame "00 00 7A 50 26 56" --frame "07 80 2F 95 C9 AE" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-he30-exact-2f95c9.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --prompt-screen --pre-read 1.0 --frame "00 00 00 00 80 DA" --frame "00 00 7A 50 26 56" --frame "00 00 2F 95 C9 29" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-he30-host-2f95c9.txt
HE30b: Compare new 2F 95 C9 with old 2F 95 09
Hypothesis:
- The new
2Fbranch may be a close sibling of the older07 C0 2F 95 09 2Ebranch fromEC -> 7B. - If so, sending the older host-shaped
2F 95 09after provoking the new2F 95 C9branch may reveal whether the last data byte is page/subtype rather than a completely separate family.
python scripts/serial_sequence_probe.py --port COM5 --prompt --prompt-screen --pre-read 1.0 --frame "00 00 00 00 80 DA" --frame "00 00 7A 50 26 56" --frame "00 00 2F 95 09 E9" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-he30-host-2f9509-after-2f95c9.txt
HE30c: Exact and host-shaped answers to 07 80 D0 50 26 7B
Hypothesis:
- If
D0 50 26is a deeper base-status family, it may respond differently to exact and host-shaped answers than the selector-space7A/7B/FBfamilies do.
python scripts/serial_sequence_probe.py --port COM5 --prompt --prompt-screen --pre-read 1.0 --frame "00 00 00 00 80 DA" --frame "00 00 40 40 30 6A" --frame "07 80 D0 50 26 7B" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-he30-exact-d05026.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --prompt-screen --pre-read 1.0 --frame "00 00 00 00 80 DA" --frame "00 00 40 40 30 6A" --frame "00 00 D0 50 26 FC" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-he30-host-d05026.txt
HE30d: Trigger-sibling probes around the 2F 95 C9 branch
Hypothesis:
- The new
2F 95 C9branch may not belong only to host7A 50 26. - Nearby host-side
7Asiblings might land on related2Fpages if this is a small camera-data family rather than a single magic value.
python scripts/serial_sequence_probe.py --port COM5 --prompt --prompt-screen --pre-read 1.0 --frame "00 00 00 00 80 DA" --frame "00 00 7A 58 26 5E" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-he30-trigger-7a5826.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --prompt-screen --pre-read 1.0 --frame "00 00 00 00 80 DA" --frame "00 00 7A 50 3A 4A" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-he30-trigger-7a503a.txt
HE30e: Trigger-sibling probes around the D0 50 26 branch
Hypothesis:
- If
D0 50 26is tied to a broader base-status surface, nearby host-side40/50/C0style pages may land on related families.
python scripts/serial_sequence_probe.py --port COM5 --prompt --prompt-screen --pre-read 1.0 --frame "00 00 00 00 80 DA" --frame "00 00 50 40 30 7A" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-he30-trigger-504030.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --prompt-screen --pre-read 1.0 --frame "00 00 00 00 80 DA" --frame "00 00 40 60 30 4A" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-he30-trigger-406030.txt
HE30f: Cold-start direct tests of the new host-shaped families
Hypothesis:
- If these families are really camera/base-status feed pages, they may work directly after boot without needing the earlier provoking host frame.
- If they do not, they are more likely to be second-stage response branches.
python scripts/serial_sequence_probe.py --port COM5 --prompt --prompt-screen --pre-read 1.0 --frame "00 00 2F 95 C9 29" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-he30-cold-2f95c9.txt
python scripts/serial_sequence_probe.py --port COM5 --prompt --prompt-screen --pre-read 1.0 --frame "00 00 D0 50 26 FC" --frame "00 00 00 00 80 DA" --repeat 2 --frame-interval 0.20 --read-after-frame 0.30 --read-after-group 0.8 --log captures/rcp-he30-cold-d05026.txt
Recommended order:
HE30aexact/host2F 95 C9HE30cexact/hostD0 50 26HE30fcold-start direct testsHE30bold-vs-new2FcomparisonHE30dandHE30etrigger-sibling probes
Reasoning:
- First check whether the new families themselves can be answered meaningfully.
- Then check whether they are direct-feed candidates or only response branches.
- Only after that spend time mapping nearby siblings.
2026-05-13 HE30 Results
This ladder did not produce a stable multi-turn exchange, but it did reveal a stronger family structure around both new HE29 branches.
HE30a: Answering 07 80 2F 95 C9 AE
Logs:
captures/rcp-he30-exact-2f95c9.txtcaptures/rcp-he30-host-2f95c9.txt
Result:
- Group 1, host
00 00 7A 50 26 56again produced:07 80 2F 95 C9 AE
- Answering that with either:
- exact
07 80 2F 95 C9 AE - or host
00 00 2F 95 C9 29produced no new stage.
- exact
- Group 2 was heartbeat-only in both runs.
Read:
2F 95 C9is real and reproducible as a one-shot branch under the7A 50 26host feed.- But it still does not behave like an immediate prompt that the host can simply echo back.
HE30b: Comparing new 2F 95 C9 to old 2F 95 09
Log:
captures/rcp-he30-host-2f9509-after-2f95c9.txt
Result:
- This run did not reproduce the new
2F 95 C9branch first. - Instead, the initial host heartbeat itself provoked:
07 80 C0 40 30 6D
- After that, host
00 00 7A 50 26 56and host00 00 2F 95 09 E9stayed heartbeat-compatible only.
Read:
- This run did not establish a useful direct relationship between
2F 95 C9and the older2F 95 09branch. - It does reinforce that these branches are timing/context-sensitive and can be pre-empted by fallback-family behavior.
HE30c: Answering 07 80 D0 50 26 7B
Logs:
captures/rcp-he30-exact-d05026.txtcaptures/rcp-he30-host-d05026.txt
Result:
- The originally observed
07 80 D0 50 26 7Bdid not reproduce exactly. - Instead,
00 00 40 40 30 6Aproduced sibling families:- exact-answer run:
07 80 50 78 26 D3 - host-answer run:
07 80 50 50 26 FB
- exact-answer run:
- Answering those with either:
- exact
07 80 D0 50 26 7B - or host
00 00 D0 50 26 FCdid not open a new stage.
- exact
- Group 2 was heartbeat-only in both runs.
Read:
- The
40-triggered branch is real, but the stable thing is not a single fixedD0family. - It looks more like a parameterized
50 xx 26sibling strip that can vary by context.
HE30d: 7A trigger siblings
Logs:
captures/rcp-he30-trigger-7a5826.txtcaptures/rcp-he30-trigger-7a503a.txt
Result:
00 00 7A 58 26 5Eproduced:07 80 2F 65 F2 65
00 00 7A 50 3A 4Aproduced:07 80 2F 95 52 35
- Both appeared in group 1 only.
- Group 2 was heartbeat-only.
Read:
- This is a strong result.
- The
7Ahost-fed branch is not a single magic trigger for one fixed2F 95 C9reply. - It looks like a family mapping:
host-side
7A ...variants can produce related2F ...response variants.
HE30e: 40/50 trigger siblings
Logs:
captures/rcp-he30-trigger-504030.txtcaptures/rcp-he30-trigger-406030.txt
Result:
00 00 50 40 30 7Aproduced:07 80 D4 50 26 7F
00 00 40 60 30 4Aproduced:07 80 50 58 26 F3
- Both appeared in group 1 only.
- Group 2 was heartbeat-only.
Read:
- This is the matching strong result on the heartbeat/base-status side.
- The
40/50host-fed branch also looks like a family mapping, not a lone one-off response.
HE30f: Cold-start direct tests
Logs:
captures/rcp-he30-cold-2f95c9.txtcaptures/rcp-he30-cold-d05026.txt
Result:
- Cold host
00 00 2F 95 C9 29did not reproduce the2Fbranch directly. - Instead, on the second group tail it drifted into:
07 80 40 40 30 ED
- Cold host
00 00 D0 50 26 FCdid not reproduce theD0/50branch directly. - Instead, on the second group tail it drifted into:
07 80 C0 40 30 6D
Read:
- These new families do not currently look like valid cold-start camera feed pages by themselves.
- They look more like second-stage response families or branch-local pages that require earlier context/stimulus.
HE30 Overall Read
Most important change in our model:
- We now have good evidence for two additional parameterized response
surfaces:
- host
7A ...-> RCP2F ... - host
40/50 ...-> RCP50/D4 ...
- host
Concrete examples:
7A 50 26->2F 95 C97A 58 26->2F 65 F27A 50 3A->2F 95 5240 40 30->50 78 26or50 50 2650 40 30->D4 50 2640 60 30->50 58 26
What this suggests:
- some host-fed family frames are acting more like query/page selectors within a deeper status space
- and the resulting RCP families are parameterized, not isolated one-offs
What it does not yet suggest:
- that we have found the full active-session feed
- that these second-stage families can simply be echoed back to advance the conversation
- that they are valid cold-start traffic on their own
Best next move after HE30:
- Stay narrow and dense-map one family at a time, especially:
- the host
7A ...-> RCP2F ...surface - the host
40/50 ...-> RCP50/D4 ...surface
- the host
- Those now look more promising than continuing to brute-force entirely new top-level selectors.
HE31: Wake-The-Panel Pass
Goal:
- Go back to the practical question: can we make the RCP behave more "awake" on the front panel, even if we still do not know the full PT2 conversation?
- Specifically watch for:
- leaving
CONNECT NOT ACT - any lamp change
- any numeric readout change
- selector/query branches becoming reusable while the run is active
- leaving
Why this pass is different:
- We now know a lot of the protocol is structured, but broad mixed streams did not wake the panel.
- That suggests the wake condition may depend more on:
- boot timing
- consistent page identity
- slower realistic cadence
- or a background base-status layer plus a single active page than on throwing many valid-looking families at it at once.
What we are testing here:
- very early boot-window traffic
- one stable page repeated instead of carousels
- base-status background plus one stable page
- CALL event path while a stable session-like stream is present
HE31a: Early-boot 90 -> E8 repeated page
Hypothesis:
- The panel may only accept wake/session framing very early after power-on.
90 -> E8is one of the cleanest structured selectors we have, so treat it like a plausible "current camera page" and present it immediately.
python scripts/serial_sequence_probe.py --port COM5 --prompt --prompt-screen --pre-read 0.2 --delay 0.0 --frame "00 00 90 00 80 4A" --frame "00 00 E8 40 30 C2" --frame "00 00 7A 50 26 56" --repeat 12 --frame-interval 0.15 --read-after-frame 0.08 --repeat-interval 0.35 --read-after-group 0.20 --log captures/rcp-he31-boot-e8-page.txt
HE31b: Early-boot base-status plus E8 page
Hypothesis:
- The panel may want a base status layer before it treats a page feed as live.
- Use the strongest current base-status candidates together with the clean
E8page family.
python scripts/serial_sequence_probe.py --port COM5 --prompt --prompt-screen --pre-read 0.2 --delay 0.0 --frame "00 00 40 40 30 6A" --frame "00 00 00 00 80 DA" --frame "00 00 90 00 80 4A" --frame "00 00 E8 40 30 C2" --frame "00 00 7A 50 26 56" --repeat 10 --frame-interval 0.15 --read-after-frame 0.08 --repeat-interval 0.35 --read-after-group 0.20 --log captures/rcp-he31-boot-base-plus-e8.txt
HE31c: Slow realistic E8 page cadence
Hypothesis:
- Our earlier fan-outs may have been too dense or too "computer-ish."
- Try a slower, more boring, repeated page cadence as if a CCU is refreshing one visible control page.
python scripts/serial_sequence_probe.py --port COM5 --prompt --prompt-screen --pre-read 1.0 --frame "00 00 90 00 80 4A" --frame "00 00 E8 40 30 C2" --frame "00 00 7A 50 26 56" --repeat 20 --frame-interval 0.25 --read-after-frame 0.10 --repeat-interval 0.80 --read-after-group 0.20 --log captures/rcp-he31-slow-e8-page.txt
HE31d: Slow realistic base-status only cadence
Hypothesis:
- If the wake condition is mostly "camera is alive and reporting status", the base-status side may matter more than the selector side at first.
python scripts/serial_sequence_probe.py --port COM5 --prompt --prompt-screen --pre-read 1.0 --frame "00 00 40 40 30 6A" --frame "00 00 00 00 80 DA" --frame "00 00 50 40 30 7A" --repeat 20 --frame-interval 0.25 --read-after-frame 0.10 --repeat-interval 0.80 --read-after-group 0.20 --log captures/rcp-he31-slow-base-status.txt
HE31e: Base-status background plus stable EC page
Hypothesis:
ECis stricter thanE8/E9and may correspond to a more central "connected" page.- Feed a background base-status layer and then one stable
ECpage only.
python scripts/serial_sequence_probe.py --port COM5 --prompt --prompt-screen --pre-read 1.0 --frame "00 00 40 40 30 6A" --frame "00 00 00 00 80 DA" --frame "00 00 90 00 80 4A" --frame "00 00 EC 40 30 C6" --frame "00 00 7B 50 26 57" --repeat 15 --frame-interval 0.20 --read-after-frame 0.10 --repeat-interval 0.60 --read-after-group 0.20 --log captures/rcp-he31-base-plus-ec.txt
HE31f: CALL while stable E8 page is present
Hypothesis:
- The panel may only treat operator events as meaningful when it sees a stable enough background page/session context.
- Keep a simple
E8page stream running, then inject the known synthetic CALL pair into the same group.
python scripts/serial_sequence_probe.py --port COM5 --prompt --prompt-screen --pre-read 1.0 --frame "00 00 90 00 80 4A" --frame "00 00 E8 40 30 C2" --frame "00 00 7A 50 26 56" --frame "00 00 15 80 00 CF" --frame "00 00 15 00 00 4F" --repeat 10 --frame-interval 0.20 --read-after-frame 0.12 --repeat-interval 0.60 --read-after-group 0.25 --log captures/rcp-he31-e8-plus-call.txt
HE31g: CALL while base-status background is present
Hypothesis:
- Same idea as above, but maybe the event path wants base-status presence more than selector-page presence.
python scripts/serial_sequence_probe.py --port COM5 --prompt --prompt-screen --pre-read 1.0 --frame "00 00 40 40 30 6A" --frame "00 00 00 00 80 DA" --frame "00 00 15 80 00 CF" --frame "00 00 15 00 00 4F" --repeat 10 --frame-interval 0.20 --read-after-frame 0.12 --repeat-interval 0.60 --read-after-group 0.25 --log captures/rcp-he31-base-plus-call.txt
Recommended order:
HE31aearly-bootE8pageHE31bearly-boot base-status plusE8HE31cslowE8page cadenceHE31ebase-status plusECHE31fE8plus CALLHE31dslow base-status onlyHE31gbase-status plus CALL
Reasoning:
- The most likely miss so far is timing and stability, not absence of valid bytes.
- So this pass biases toward:
- early boot
- one stable page
- one stable background layer
- and one meaningful operator event
2026-05-13 HE31 Results
Front-panel result:
- No HE31 run visibly woke the panel.
- No useful LCD, lamp, or numeric-display change was recorded.
Note on the PANEL lines in some logs:
- A few captures contain the next command line pasted into the
--prompt-screenprompt. - Those lines are not treated as evidence of panel state.
HE31a: Early-boot E8 page
Log:
captures/rcp-he31-boot-e8-page.txt
Result:
- Group 1 did produce the expected early structured branch:
07 80 FA 50 26 51
- Groups 2-12 then stayed heartbeat-compatible only.
Read:
- Starting very early after boot did not turn the
E8page stream into a reusable or session-like wake path. - It still behaved like a one-shot branch that immediately collapsed.
HE31b: Early-boot base-status plus E8
Log:
captures/rcp-he31-boot-base-plus-e8.txt
Result:
- Group 1 briefly produced:
07 80 40 40 30 ED
- After that, the whole run stayed heartbeat-compatible.
- No later
E8page family reopened.
Read:
- Adding a base-status layer at boot did not help
E8; it actually biased the run toward the known fallback/transient family.
HE31c: Slow realistic E8 page cadence
Log:
captures/rcp-he31-slow-e8-page.txt
Result:
- Group 1 produced the familiar:
07 80 7A 50 26 D1
- Groups 2-20 then stayed heartbeat-compatible only.
Read:
- A slower, more boring cadence did not make the
E8page stream feel more alive to the panel. - So the earlier dense fan-outs likely were not failing just because they were too fast or too "computer-ish."
HE31d: Slow base-status only cadence
Log:
captures/rcp-he31-slow-base-status.txt
Result:
- Group 1 produced:
07 80 40 40 30 ED
- Groups 2-20 then stayed heartbeat-compatible only.
Read:
- Repeating only the base-status side also failed to wake the panel.
- It behaved like a fallback-presence layer, not a true active-session layer.
HE31e: Base-status plus stable EC
Log:
captures/rcp-he31-base-plus-ec.txt
Result:
- Group 1 produced:
07 80 40 60 30 CD
- After that, the full run stayed heartbeat-compatible.
ECdid not reopen a stable7Bpage under this background.
Read:
- Even the stricter
ECbranch did not become more useful under a stable base-status background. - This argues against "just add one richer page on top of base status" as the missing wake condition.
HE31f: E8 page plus CALL
Log:
captures/rcp-he31-e8-plus-call.txt
Result:
- Group 1 again showed the early
E8branch:07 80 FA 50 26 51
- The following synthetic CALL pair:
00 00 15 80 00 CF00 00 15 00 00 4Fproduced only heartbeat-compatible traffic.
- No
0x45CALL-family reply appeared.
Read:
- A stable
E8page context does not make the CALL synthetic event path become richer or more session-like. - In this context, CALL actually looks less interesting than in the earlier dedicated CALL work.
HE31g: Base-status plus CALL
Log:
captures/rcp-he31-base-plus-call.txt
Result:
- Group 1 produced:
07 80 40 40 30 ED
- The synthetic CALL pair after that stayed heartbeat-compatible only.
- No
0x45CALL-family reply appeared.
Read:
- Base-status presence also does not make CALL act like a wake/session trigger.
HE31 Overall Read
The wake-oriented pass answers a few important questions pretty cleanly:
- Early boot timing alone is not enough.
- One stable repeated page alone is not enough.
- Base-status background plus one page is not enough.
- CALL injected into those contexts is not enough.
Most important practical conclusion:
- The panel still does not look like it is waiting for merely:
- a believable page stream
- a believable base-status stream
- or an operator event inside those streams
So the missing wake condition is probably something more specific, such as:
- a CCU identity/mode declaration we still have not found
- a different class of background page entirely
- or a stricter startup sequence/order than our current page-first models
HE32: Best-Shot Startup / Handshake Ladder
Goal:
- Try the most plausible remaining startup shapes rather than broad exploration.
- Bias toward sequences that feel more like a real CCU boot:
- declare identity or capability once
- select a page once
- then maintain a simpler background/value stream
Why these are the best next options:
- HE31 suggests the panel is not waking on:
- simple early boot timing
- one stable repeated page
- base-status plus one page
- CALL inside those contexts
- So the stronger remaining hypothesis is that we are missing a more structured startup order, not just more valid traffic.
Current best candidate building blocks:
- possible identity / discovery:
00 00 A0 00 80 7A00 00 B0 00 80 6A00 00 B5 00 80 6F
- possible opener / page-class:
00 00 90 00 80 4A00 00 AF 00 80 75
- possible maintained page feed:
00 00 E8 40 30 C200 00 7A 50 26 56
- possible maintained background:
00 00 00 00 80 DA00 00 40 40 30 6A00 00 50 40 30 7A
What would count as a hit:
- any visible wake-up on the panel
- selector/query families reopening later in the same run
- a new recurring non-heartbeat family replacing the current idle rhythm
- a run that behaves differently from the usual "group 1 only, then collapse"
HE32a: Discovery-first, then 90 -> E8, then maintained 7A
Hypothesis:
- The panel may want to see readable identity/capability pages before it accepts a page/value stream.
python scripts/serial_sequence_probe.py --port COM5 --prompt --prompt-screen --pre-read 0.5 --frame "00 00 A0 00 80 7A" --frame "00 00 B0 00 80 6A" --frame "00 00 B5 00 80 6F" --frame "00 00 90 00 80 4A" --frame "00 00 E8 40 30 C2" --frame "00 00 7A 50 26 56" --frame "00 00 00 00 80 DA" --frame "00 00 7A 50 26 56" --frame "00 00 00 00 80 DA" --frame "00 00 7A 50 26 56" --read-after-frame 0.15 --frame-interval 0.20 --read-after-group 2.0 --log captures/rcp-he32-discovery-then-e8-maintain.txt
HE32b: A0 -> 90 -> E8, then heartbeat-only maintenance
Hypothesis:
- The missing piece may be a one-time selector/opening chain, with heartbeat alone sufficient afterward.
python scripts/serial_sequence_probe.py --port COM5 --prompt --prompt-screen --pre-read 0.5 --frame "00 00 A0 00 80 7A" --frame "00 00 90 00 80 4A" --frame "00 00 E8 40 30 C2" --frame "00 00 7A 50 26 56" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --frame "00 00 00 00 80 DA" --read-after-frame 0.15 --frame-interval 0.20 --read-after-group 3.0 --log captures/rcp-he32-a0-90-e8-heartbeat-tail.txt
HE32c: A0 -> 90 -> E8, then 7A-only maintenance
Hypothesis:
- Heartbeat may only mean "host present," while
7A 50 26may be the real page value stream the panel wants once opened.
python scripts/serial_sequence_probe.py --port COM5 --prompt --prompt-screen --pre-read 0.5 --frame "00 00 A0 00 80 7A" --frame "00 00 90 00 80 4A" --frame "00 00 E8 40 30 C2" --frame "00 00 7A 50 26 56" --frame "00 00 7A 50 26 56" --frame "00 00 7A 50 26 56" --frame "00 00 7A 50 26 56" --read-after-frame 0.15 --frame-interval 0.25 --read-after-group 3.0 --log captures/rcp-he32-a0-90-e8-7a-tail.txt
HE32d: AF -> 90 -> E8, then maintained FA
Hypothesis:
AFmay be a more camera-flavored opener, andFA 50 26may be the sibling page/value family this context actually wants.
python scripts/serial_sequence_probe.py --port COM5 --prompt --prompt-screen --pre-read 0.5 --frame "00 00 AF 00 80 75" --frame "00 00 90 00 80 4A" --frame "00 00 E8 40 30 C2" --frame "00 00 FA 50 26 D6" --frame "00 00 00 00 80 DA" --frame "00 00 FA 50 26 D6" --frame "00 00 00 00 80 DA" --frame "00 00 FA 50 26 D6" --read-after-frame 0.15 --frame-interval 0.20 --read-after-group 2.0 --log captures/rcp-he32-af-90-e8-fa-tail.txt
HE32e: A0 -> AF -> EC, then maintained 7B
Hypothesis:
ECis stricter thanE8; it may need both a general opener and a mode opener before the page/value feed makes sense.
python scripts/serial_sequence_probe.py --port COM5 --prompt --prompt-screen --pre-read 0.5 --frame "00 00 A0 00 80 7A" --frame "00 00 AF 00 80 75" --frame "00 00 EC 40 30 C6" --frame "00 00 7B 50 26 57" --frame "00 00 00 00 80 DA" --frame "00 00 7B 50 26 57" --frame "00 00 00 00 80 DA" --frame "00 00 7B 50 26 57" --read-after-frame 0.15 --frame-interval 0.20 --read-after-group 2.0 --log captures/rcp-he32-a0-af-ec-7b-tail.txt
HE32f: Repeated 90 identity beacon, then single E8 page
Hypothesis:
- The panel may want to see a short identity/mode beacon first, before any page selection at all.
python scripts/serial_sequence_probe.py --port COM5 --prompt --prompt-screen --pre-read 0.5 --frame "00 00 90 00 80 4A" --frame "00 00 90 00 80 4A" --frame "00 00 90 00 80 4A" --frame "00 00 E8 40 30 C2" --frame "00 00 7A 50 26 56" --frame "00 00 00 00 80 DA" --frame "00 00 7A 50 26 56" --read-after-frame 0.15 --frame-interval 0.25 --read-after-group 2.5 --log captures/rcp-he32-90-beacon-then-e8.txt
HE32g: Repeated AF identity beacon, then single EC page
Hypothesis:
- Same idea as above, but aimed at the stricter
ECbranch.
python scripts/serial_sequence_probe.py --port COM5 --prompt --prompt-screen --pre-read 0.5 --frame "00 00 AF 00 80 75" --frame "00 00 AF 00 80 75" --frame "00 00 AF 00 80 75" --frame "00 00 EC 40 30 C6" --frame "00 00 7B 50 26 57" --frame "00 00 00 00 80 DA" --frame "00 00 7B 50 26 57" --read-after-frame 0.15 --frame-interval 0.25 --read-after-group 2.5 --log captures/rcp-he32-af-beacon-then-ec.txt
Recommended order:
HE32adiscovery-first thenE8HE32bA0 -> 90 -> E8then heartbeat tailHE32cA0 -> 90 -> E8then7AtailHE32eA0 -> AF -> ECthen7BtailHE32f90beacon thenE8HE32dAF -> 90 -> E8thenFAtailHE32gAFbeacon thenEC
Reasoning:
- These are the strongest remaining handshake-shaped guesses:
- discovery before page
- stacked openers rather than alternative openers
- set-once then maintain-later
- beacon first, page second
2026-05-13 HE32 Results
Front-panel result:
- No HE32 startup/handshake sequence visibly woke the panel.
- No useful LCD, lamp, or readout change was observed.
Serially, though, the ladder was still informative: the panel did not become "live", but several of the startup-shaped sequences diverted into alternate one-shot response families instead of opening the expected page streams.
HE32a: Discovery-first, then 90 -> E8, then maintained 7A
Log:
captures/rcp-he32-discovery-then-e8-maintain.txt
Result:
A0produced no structured reply in this run.B0produced the known readable block:07 80 6C 40 30 C1
B5then produced no new stage.- The later
90 -> E8 -> 7Aportion stayed heartbeat-compatible only.
Read:
- Discovery-first ordering did not turn later page maintenance into a live session.
- It mostly behaved like "consume one discovery/readable block, then collapse."
HE32b: A0 -> 90 -> E8, then heartbeat-only maintenance
Log:
captures/rcp-he32-a0-90-e8-heartbeat-tail.txt
Result:
A0 -> 90produced a new family:07 80 64 40 30 C9
- After that,
E8,7A, and the heartbeat tail stayed heartbeat-compatible.
Read:
- This is a useful new lead.
A0 -> 90does not look like a wake path, but it does look like a distinct startup/opening branch rather than random failure.
HE32c: A0 -> 90 -> E8, then 7A-only maintenance
Log:
captures/rcp-he32-a0-90-e8-7a-tail.txt
Result:
- This reproduced the same startup branch more strongly:
07 80 64 40 30 C9
- Repeated
7A 50 26after that did not open a new stage.
Read:
64 40 30now looks real, not a one-off accident.- It is associated with the
A0 -> 90stacked-opener idea, not with a live maintained page stream.
HE32d: AF -> 90 -> E8, then maintained FA
Log:
captures/rcp-he32-af-90-e8-fa-tail.txt
Result:
AF -> 90also diverted into the same family:07 80 64 40 30 C9
- The later
E8and repeatedFAhost feed stayed heartbeat-compatible only.
Read:
64 40 30is not unique toA0 -> 90;AF -> 90can also land there.- That makes it look more like a startup/opening class than a branch-local oddity.
HE32e: A0 -> AF -> EC, then maintained 7B
Log:
captures/rcp-he32-a0-af-ec-7b-tail.txt
Result:
A0 -> AFproduced another distinct family:07 80 0D 04 AB 7F
ECand the repeated7Bhost feed after that stayed heartbeat-compatible.
Read:
- This is another useful startup-shaped diversion:
A0 -> AFappears to open a discovery/status-like family of its own. - But again, it did not enable the later page/value stream.
HE32f: Repeated 90 beacon, then single E8 page
Log:
captures/rcp-he32-90-beacon-then-e8.txt
Result:
- This capture contains two runs.
- Run 1:
- repeated
90beacon produced07 80 64 40 30 C9
- repeated
- Run 2:
- repeated
90beacon produced07 80 E4 40 30 49
- repeated
- In both runs, the later
E8 -> 7Aportion stayed heartbeat-compatible only.
Read:
- Repeated
90by itself is not waking the panel, but it is clearly not meaningless. - It can steer the panel into at least two startup/readable families:
64 40 30E4 40 30
HE32g: Repeated AF beacon, then single EC page
Log:
captures/rcp-he32-af-beacon-then-ec.txt
Result:
- Repeated
AFbeacon produced:07 80 0D 04 EB 3F
- The later
EC -> 7Bportion stayed heartbeat-compatible only.
Read:
- Repeated
AFalso looks meaningful as a startup beacon, but again only in the sense of opening a one-shot family, not in waking the panel into a live session.
HE32 Overall Read
This ladder did not wake the panel, but it did sharpen the handshake model:
- the panel is still not waking on our best "declare then maintain" startup sequences
- but stacked openers and beacon-like traffic are clearly meaningful
New startup-shaped families observed:
A0 -> 90orAF -> 90->07 80 64 40 30 C9- repeated
90beacon ->07 80 64 40 30 C9or07 80 E4 40 30 49 A0 -> AF->07 80 0D 04 AB 7F- repeated
AFbeacon ->07 80 0D 04 EB 3F
Best current interpretation:
90andAFare increasingly looking like mode/class beacons or startup selectors, not just ordinary page openers- but the missing wake condition is still something beyond those beacon effects
- once one of these startup families is opened, the later page/value stream still collapses to heartbeat instead of becoming active
So HE32 rules out another important family of guesses:
- the panel does not appear to wake just because we got the startup order closer to reality
It may still require:
- a different class of maintained traffic after those beacon stages
- a missing hardware/state signal on another wire
- or a specific startup family we have touched indirectly but not yet maintained
2026-05-13 CAM POWER Context Retests
Goal:
- Re-test the older
CAM POWERexact echo inside stronger modern contexts:- stable
E8page context - base-status context
- stable
- See whether
CAM POWERstarts to behave like a meaningful event once the panel already has more believable host/session traffic behind it.
Logs found:
captures/rcp-cam-power-e8-context-exact-echo.txtcaptures/rcp-cam-power-base-context-exact-echo.txt
Note:
- I do not currently see separate host-shaped context reruns in
captures/. This section only reflects the two exact-echo context captures that are present.
CAM POWER exact echo inside E8 page context
Sequence:
- repeating startup page stream:
00 00 90 00 80 4A00 00 E8 40 30 C200 00 7A 50 26 56
- button response:
00 00 07 80 00 DD
Result:
- The page stream initially produced the known
E8family:07 80 7A 50 26 D1
- During the run, the panel emitted repeated
CAM POWERevent frames:00 00 07 80 00 DD
- When the exact echo was finally sent back, no new structured response family appeared afterward.
- The run remained on button-event / heartbeat-class behavior with no visible wake-up.
Read:
- Stronger page context does not make the older exact
CAM POWERecho turn into a session-advancing command. - It does show that
CAM POWERtraffic can coexist with theE8page stream without disrupting the panel into a richer state.
CAM POWER exact echo inside base-status context
Sequence:
- repeating startup base-status stream:
00 00 40 40 30 6A00 00 00 00 80 DA00 00 50 40 30 7A
- button response:
00 00 07 80 00 DD
Result:
- The first startup cycle briefly showed:
07 80 C0 40 30 6D
- After that, the run settled into plain heartbeat-compatible traffic.
- No useful new structured response appeared after the base-status context.
- No visible wake-up occurred.
Read:
- Base-status context also does not make the exact
CAM POWERecho behave like a meaningful wake/session event. - Compared with the
E8context run, this one looks even flatter.
Context-Retest Read
What changed:
- We re-tested
CAM POWERexact echo inside stronger session-like backgrounds.
What did not change:
- no panel wake-up
- no new session-like serial stage
- no evidence that
CAM POWERbecomes a useful host/CCU handshake element when wrapped inE8page traffic or base-status traffic
Best current read: