2089 lines
58 KiB
Markdown
2089 lines
58 KiB
Markdown
|
||
|
||
|
||
|
||
1. -859-859-13(1)
|
||
|
||
|
||
# Remote Control Panel
|
||
|
||
|
||
## Operating Instructions
|
||
|
||
|
||
Before operating the unit, please read this manual
|
||
thoroughly and retain it for future reference.
|
||
|
||
|
||
## RCP-TX7
|
||
|
||
|
||
- ã 1997 by Sony Corporation
|
||
|
||
|
||
|
||
|
||
# For the customers in the USA
|
||
|
||
|
||
This equipment has been tested and found to comply with the
|
||
limits for a Class A digital device, pursuant to Part 15 of the
|
||
FCC Rules. These limits are designed to provide reasonable
|
||
protection against harmful interference when the equipment
|
||
is operated in a commercial environment. This equipment
|
||
generates, uses, and can radiate radio frequency energy
|
||
and, if not installed and used in accordance with the
|
||
instruction manual, may cause harmful interference to radio
|
||
communications. Operation of this equipment in a residential
|
||
area is likely to cause harmful interference in which case the
|
||
user will be required to correct the interference at his own
|
||
expense.
|
||
|
||
|
||
You are cautioned that any changes or modifications not
|
||
expressly approved in this manual could void your authority
|
||
to operate this equipment.
|
||
|
||
|
||
This device requires shielded interface cables to comply with
|
||
FCC emission limits.
|
||
|
||
|
||
2
|
||
|
||
|
||
|
||
|
||
|Table of Contents|
|
||
|---|
|
||
||
|
||
|
||
|
||
Overview ............................................................................ 4
|
||
Location and Function of Parts ....................................... 5
|
||
Operation Panel and Connector........................................... 5
|
||
1 Main Operation Section................................................ 5
|
||
2 Menu Operation/Setting Display Section ..................... 7
|
||
3 Paint section and CALL button .................................... 8
|
||
Menu Operations .............................................................12
|
||
Displaying menus .............................................................. 12
|
||
Basic Menu Operations ..................................................... 14
|
||
Menu Contents .................................................................. 15
|
||
File Operations ................................................................21
|
||
Operating Scene Files........................................................ 23
|
||
Operating Setup Files (for DXC-D30/D30P Only) ........... 24
|
||
Skin Detail Correction/Skin Matrix Adjustment
|
||
(for DXC-D30/D30P Only) ...........................................25
|
||
Multi-Camera Control......................................................26
|
||
Operating Multiple Cameras from One RCP Unit
|
||
- Command Link........................................................ 26
|
||
Adjusting the Iris and Master Black of Multiple Cameras
|
||
at One Time .................................................................. 27
|
||
Data Transfer Among Multiple Cameras .......................... 27
|
||
Specifications ..................................................................28
|
||
|
||
|
||
3
|
||
|
||
|
||
|
||
|
||
|Overview Overview|
|
||
|---|
|
||
||
|
||
|
||
|
||
The RCP-TX7 Remote Control Panel enables remote
|
||
operation of the DXC-D30/D30P or DXC-637 series
|
||
Color Video Camera.
|
||
This unit's features are described below.
|
||
|
||
|
||
|Connectable to camera control unit or|
|
||
|---|
|
||
|camera head|
|
||
|When a CCU (CCU-TX7/TX7P Camera Control Unit)|
|
||
|has been connected to a CA (CA-TX7/TX7P Camera|
|
||
|Adaptor) that is docked with a camera head, this unit|
|
||
|can be connected to the CCU to enable remote|
|
||
|operation of the camera via the CCU.|
|
||
|When the DXC-D30/D30P is docked with a CA-537/|
|
||
|537P Camera Adaptor or VCR, this unit can be|
|
||
|connected to the DXC-D30/D30P to enable direct|
|
||
|operation of the camera.|
|
||
|Full control of shooting operations|
|
||
|Besides controlling camera adjustments and settings,|
|
||
|this unit can control tripod operations (pan and tilt)|
|
||
|lens settings (focus and zoom).|
|
||
|Confirmation of camera conditions and|
|
||
|operation status|
|
||
|This unit's LCD indicates camera conditions|
|
||
|such as the filter value, and lens|
|
||
|extender The results of the camera's self-|
|
||
|diagnosis tests are also displayed on the LCD panel.|
|
||
|Scene file|
|
||
|The unit provides memory to hold data on shooting|
|
||
|conditions for 16 different scenes, to enable|
|
||
|readjustment of the camera for any memorized scenes.|
|
||
|
||
|
||
and
|
||
|
||
|
||
# Coordination of settings among several cameras
|
||
|
||
|
||
In a system that includes several cameras that are
|
||
connected via CCUs, connecting the CCUs allows this
|
||
unit to set up all of the cameras into the same color
|
||
condition.
|
||
|
||
|
||
# High-precision and high-speed control
|
||
|
||
|
||
Commands can be issued at high speed, which means
|
||
that remote operation with the unit's knobs can be
|
||
performed more smoothly than with previous remote
|
||
control devices. Also, high-precision data transfer
|
||
raises control precision.
|
||
|
||
|
||
4
|
||
|
||
|
||
|
||
|
||
# Location and Function of Parts
|
||
|
||
|
||
Operation Panel and Connector
|
||
|
||
|
||
The following figure shows external views of this unit.
|
||
|
||
|
||
CCU/camera connector
|
||
|
||
|
||
(10-pin): Use the
|
||
|
||
|
||
supplied cable to connect
|
||
this unit to a CCU or
|
||
camera head. The power
|
||
supply to this unit and the
|
||
signal exchange are both
|
||
carried out via this
|
||
connector.
|
||
|
||
|
||
1 Main operation section
|
||
|
||
|
||
2 Menu operation/setting display
|
||
section (see page 7)
|
||
|
||
|
||
|
||
|
||
|
||
3 Paint section and CALL button
|
||
(see page 8)
|
||
|
||
|
||
REMOTE CONTROL PANEL
|
||
|
||
|
||
Operation panel
|
||
|
||
|
||
1 Main Operation Section
|
||
|
||
|
||
## 1 TALLY indicator
|
||
|
||
|
||
## 2 STANDARD button
|
||
|
||
|
||
## 3 MASTER and SLAVE buttons
|
||
|
||
|
||
||||||
|
||
|---|---|---|---|---|
|
||
|
||
|
||
## 4 CAM POWER switch
|
||
|
||
|
||
## 5 BARS button
|
||
|
||
|
||
## 6 AUTO SETUP buttons
|
||
|
||
|
||
## 7 MONITOR SELECT buttons
|
||
|
||
|
||
## 8 OPERATE knob
|
||
|
||
|
||
G BSEQ ENC
|
||
MONITOR SELECT
|
||
|
||
|
||
OPERATE
|
||
|
||
|
||
5
|
||
|
||
|
||
|
||
|
||
# Location and Function of Parts
|
||
|
||
|
||
1 TALLY indicator
|
||
Lights in red when a red tally signal from the CA or
|
||
CCU is received and lights in green when a green tally
|
||
signal is received.
|
||
|
||
|
||
2 STANDARD button
|
||
Press to automatically set up the camera for use under
|
||
standard shooting conditions.
|
||
|
||
|
||
3 MASTER and SLAVE buttons (only when this
|
||
unit is connected to CCU)
|
||
When using several remote control panels connected to
|
||
CCUs, press the MASTER button on the unit to be
|
||
used as the master unit and press the SLAVE button on
|
||
all other units (slave units). Both buttons light when
|
||
pressed.
|
||
Once a unit has been set as the master unit, the
|
||
MASTER button on any other unit cannot be operated.
|
||
To select other unit for master unit, press the
|
||
MASTER button on the current master unit again.
|
||
(The button goes out.)
|
||
|
||
|
||
For details, see "Multi-Camera Control" on page 26.
|
||
|
||
|
||
4 CAM (camera) POWER switch (only when this
|
||
unit is connected to CCU)
|
||
When the power supply is on for the CCU, CA and
|
||
camera head, this switch lights. You can then turn the
|
||
power supply for the camera on or off by pressing the
|
||
switch. The switch lights when the power is on, and
|
||
goes out when the power is off. It takes a moment
|
||
until the power is being turned on or off after the
|
||
switch is pressed. (The switch blinks meanwhile.)
|
||
|
||
|
||
5 BARS (color bars) button
|
||
Press to output color bars from the camera when this
|
||
unit has been connected to a camera. When this unit
|
||
has been connected to a CCU, press this button to
|
||
output color bars from the CCU's internal color bar
|
||
generator.
|
||
|
||
|
||
6 AUTO SETUP buttons
|
||
Press one of these buttons to set up the camera
|
||
automatically for the corresponding item. The buttons
|
||
will blink when pressed.
|
||
Operations of the button are as follows:.
|
||
|
||
|
||
6
|
||
|
||
|
||
## Button Operation
|
||
|
||
|
||
SKIN DETAIL Recalls the AUTO SKIN menu and
|
||
(only for DXC- performs automatic designation of the
|
||
D30/D30P) skin gate area.a)
|
||
a)Skin gate area: target color range of skin detail correction
|
||
or skin matrix adjustment
|
||
|
||
|
||
|LEVEL|Performs auto white balance or auto black balance adjustments. (During adjustment, indications appear on the LCD panel in the menu operation/setting display 2.) When using a DXC-D30/ D30P, the R/B gamma is set to the standard value.|
|
||
|---|---|
|
||
|WHITE|Performs auto white balance adjustment. (During adjustment, indications appear on the LCD panel in the menu operation/ setting display 2.)|
|
||
|BLACK|Performs auto black balance adjustment. (During adjustment, indications appear on the LCD panel in the menu operation/ setting display 2.)|
|
||
|
||
|
||
|Button|Output signal|
|
||
|---|---|
|
||
|R|R signal (The G and B signals can be selected at the same time.)|
|
||
|G|G signal (The R and B signals can be selected at the same time.)|
|
||
|B|B signal (The R and G signals can be selected at the same time.)|
|
||
|SEQ|WFM connector: R, G and B sequence signal PIX connector: signal selected last|
|
||
|ENC|Composite video signal|
|
||
|
||
|
||
7 MONITOR SELECT buttons (only when this
|
||
unit is connected to CCU)
|
||
Press one of these buttons to select the type of signal
|
||
output via the PIX and WFM connectors on the CCU's
|
||
rear panel. The buttons will light when pressed.
|
||
The following signals can be selected.
|
||
|
||
|
||
8 OPERATE knob
|
||
Locks some of the buttons and knobs on the control
|
||
panel.
|
||
FULL: No locking.
|
||
PAINT: Locks the buttons and knobs except for
|
||
those in the paint section 3, CALL button 3,
|
||
AUTO SETUP buttons 6 (excluding LEVEL
|
||
button) and MONITOR SELECT buttons 7.
|
||
IRIS/M.BLACK: Locks the buttons and knobs
|
||
except for those in the iris adjustment block and
|
||
master black adjustment block in the paint section
|
||
3, CALL button 3, and MONITOR SELECT
|
||
buttons 7.
|
||
LOCK: Locks the buttons and knobs except for the
|
||
CALL button 3 and MONITOR SELECT
|
||
buttons 7.
|
||
|
||
|
||
|
||
|
||
# 2 Menu Operation/Setting Display Section
|
||
|
||
|
||
## DETAIL GAMMA KNEE
|
||
|
||
|
||
## FLARE RECALL STORE
|
||
|
||
|
||
1 Menu selection buttons
|
||
|
||
|
||
## FILTER LENSE PAN/TILT SKIN SKIN GATE DETAIL
|
||
|
||
|
||
## SHADING MATRIX
|
||
|
||
|
||
## DYNA BLACK TLCS AUTO LATITUDE STRETCH FUNCTION
|
||
|
||
|
||
## DIAG OTHERS
|
||
|
||
|
||
2 LCD panel
|
||
|
||
|
||
3 INDICATION button
|
||
|
||
|
||
8 Setting buttons
|
||
|
||
|
||
## INDICATION PAGE
|
||
|
||
|
||
## BRIGHT
|
||
|
||
|
||
## PREV
|
||
|
||
|
||
7 BRIGHT knob
|
||
|
||
|
||
4 PAGE buttons
|
||
|
||
|
||
## CONTR
|
||
|
||
|
||
## NEXT
|
||
|
||
|
||
6 CONTR knob
|
||
|
||
|
||
5 Setting knobs
|
||
|
||
|
||
1 Menu selection buttons
|
||
Press one of these buttons to have the corresponding
|
||
menu displayed on the LCD panel 2.
|
||
|
||
|
||
For details, see "Basic Menu Operations" page 14.
|
||
|
||
|
||
2 LCD panel
|
||
Displays menus, messages reporting the progress or
|
||
results of operations, current settings, etc.
|
||
|
||
|
||
3 INDICATION button
|
||
Press this button to change indications on the LCD
|
||
panel in the following order:
|
||
Current settings of detail level, gamma and knee n
|
||
Current setting of white balance n Current setting of
|
||
black balance n Current setting of flare (when the
|
||
FLARE button in the black balance adjustment/flare
|
||
correction block is lit) n No indications and back to
|
||
current settings of detail level, gamma and knee
|
||
If you press this button while a menu is indicated, the
|
||
menu indication disappears and then current settings of
|
||
detail level, gamma and knee appear.
|
||
|
||
|
||
4 PAGE buttons
|
||
Press the PREV button to display the previous menu
|
||
page or the NEXT button to display the next menu
|
||
page. (Each press goes back or forward one page.)
|
||
Pressing both buttons simultaneously displays the first
|
||
menu page.
|
||
|
||
|
||
For details, see "Basic Menu Operations" on page 14.
|
||
|
||
|
||
5 Setting knobs
|
||
Use these knobs to change the settings in various
|
||
menus.
|
||
|
||
|
||
For details, see "Basic Menu Operations" on page 14.
|
||
|
||
|
||
6 CONTR (contrast) knob
|
||
Adjusts the contrast of the LCD panel 2 display.
|
||
|
||
|
||
7 BRIGHT (brightness) knob
|
||
Adjusts the brightness of the LCD panel 2 display.
|
||
|
||
|
||
8 Setting buttons
|
||
Use these buttons to select functions or settings in
|
||
various menus.
|
||
|
||
|
||
For details, see "Basic Menu Operations" on page 14.
|
||
|
||
|
||
7
|
||
|
||
|
||
|
||
|
||
# Location and Function of Parts
|
||
|
||
|
||
3 Paint section and CALL button
|
||
|
||
|
||
## C.SCAN DPR
|
||
|
||
|
||
!™ Shutter setting block
|
||
|
||
|
||
1 Master gain setting block
|
||
|
||
|
||
## ON/OFF SHUTTER
|
||
|
||
|
||
## MASTER GAIN
|
||
|
||
|
||
!¡ DETAIL knob
|
||
|
||
|
||
2 SKIN DETAIL button
|
||
|
||
|
||
## SKIN DETAIL
|
||
|
||
|
||
## AUTO
|
||
|
||
|
||
## DETAIL MASTER GAMMA
|
||
|
||
|
||
3 Knee correction block
|
||
|
||
|
||
0 MASTER GAMMA knob
|
||
|
||
|
||
## KNEE
|
||
|
||
|
||
## BLACK
|
||
|
||
|
||
4 White balance adjustment
|
||
block
|
||
|
||
|
||
## AUTO AUTO PRESET MANUAL
|
||
|
||
|
||
## WHITE
|
||
|
||
|
||
## MANUAL
|
||
|
||
|
||
5 Black balance adjustment/
|
||
flare correction block
|
||
|
||
|
||
## FLARE BLACK/FLARE
|
||
|
||
|
||
## AUTO EXT
|
||
|
||
|
||
## CLOSE OPEN COARSE
|
||
|
||
|
||
## MASTER BLACK
|
||
|
||
|
||
## IRIS
|
||
|
||
|
||
9 Master black adjustment
|
||
block
|
||
|
||
|
||
6 Iris adjustment block
|
||
|
||
|
||
## SENS
|
||
|
||
|
||
8 CALL button
|
||
|
||
|
||
## CALL
|
||
|
||
|
||
## IRIS/M.BLACK LINK
|
||
|
||
|
||
## REMOTE CONTROL PANEL
|
||
|
||
|
||
7 IRIS/M.BLACK LINK button
|
||
|
||
|
||
1 Master gain setting block
|
||
Includes the buttons, a display window, and a DPR
|
||
indicator described below.
|
||
The setting that can be performed via this block differ
|
||
according to the connected camera.
|
||
When using a DXC-D30/D30P: Select the gain
|
||
value from -3, 0, +3, +6, +9, +12, +18, +24 dB,
|
||
and HYPER GAIN. (HYPER GAIN equals 30 dB
|
||
|
||
|
||
+ DPR, but the DPR indicator will not light if it is
|
||
|
||
|
||
selected.)
|
||
When using a DXC-637 series camera: Select the
|
||
gain level from LOW, MID and HIGH. The gain
|
||
value corresponding to each value is set by
|
||
camera.
|
||
|
||
|
||
8
|
||
|
||
|
||
Name Operation
|
||
4 (up) button Each press of this button raises the
|
||
setting value by one step.
|
||
When using the DXC-D30/D30P, press
|
||
the up and down buttons simultaneously
|
||
to set the master gain to 0 dB.
|
||
|
||
|
||
|$ (down) button|Each press of this button lowers the setting value by one step. When using the DXC-D30/D30P, press the up and down buttons simultaneously to set the master gain to 0 dB.|
|
||
|---|---|
|
||
|DPR button and indicator|When the master gain is set at 18 or 24 dB, press this button to activate DPR function a).|
|
||
|Display window|Displays the current master gain value.|
|
||
|
||
|
||
a)DPR (Dual Pixel Readout) function: When this function is
|
||
active, CCD output signal readout is performed one pair
|
||
of two adjacent pixels after another instead of one pixel
|
||
after another. Sensitivity increases (but resolution
|
||
decreases) as signal readout take place at a time for the
|
||
two pixels in each pair.
|
||
|
||
|
||
2 SKIN DETAIL button (only when using DXC-
|
||
D30/D30P)
|
||
Press to perform skin detail correction. (The button
|
||
will light when pressed.)
|
||
|
||
|
||
For details, see "Skin Detail Correction/Skin Matrix
|
||
Adjustment (for DXC-D30/D30P Only) "on page 25.
|
||
|
||
|
||
|
||
|
||
3 Knee correction block
|
||
Press the AUTO button to activate the auto knee
|
||
circuit. The button will light when pressed. However,
|
||
when the DynaLatitude function is set to on (see
|
||
DYNA LATITUDE on page 16), the auto knee circuit
|
||
automatically activates and the AUTO button lights.
|
||
When the AUTO button is not lit and "VARIABLE" is
|
||
selected in the KNEE menu, you can use the knob in
|
||
this block to manually adjust the knee point value.
|
||
To use the preset value, select "PRESET" in the
|
||
KNEE menu.
|
||
|
||
|
||
For details of the KNEE menu, see page 15 (for DXC-D30/
|
||
D30P) or 19 (for DXC-637 series).
|
||
|
||
|
||
4 White balance adjustment block
|
||
Use the following buttons and knobs to automatically
|
||
or manually adjust the white balance. The buttons and
|
||
knobs operate differently according to the connected
|
||
camera.
|
||
|
||
|
||
# When using the DXC-D30/D30P:
|
||
|
||
|
||
# Name Operation
|
||
|
||
|
||
AUTO (auto Press this button (which lights when
|
||
adjust) button pressed) to perform automatic white
|
||
balance adjustment.
|
||
This button does not operate while the
|
||
ATW function a) is operating. (See the
|
||
ATW in the AUTO FUNCTION menu on
|
||
page 16.)
|
||
|
||
|
||
|PRESET button|Press this button (which lights when pressed) to use the preset white balance settings. This button does not operate while the ATW function is operating. (See the ATW in the AUTO FUNCTION menu on page 16.)|
|
||
|---|---|
|
||
|MANUAL button|When this button is pressed and lit, the white balance can be manually adjusted. This button does not operate while the ATW function is operating. (See the ATW in the AUTO FUNCTION menu on page 16.)|
|
||
|WHITE (white balance) R knob|When the MANUAL button is lit, use this knob to adjust the R signal gain.|
|
||
|WHITE (white balance) B knob|When the MANUAL button is lit, use this knob to adjust the B signal gain.|
|
||
|
||
|
||
a)ATW (Auto Tracing White balance) function: This
|
||
function automatically adjusts the white balance when
|
||
lighting conditions change.
|
||
|
||
|
||
# When using the DXC-637 series:
|
||
|
||
|
||
# Name Operation
|
||
|
||
|
||
|AUTO (auto adjust) button|Press this button (which lights when pressed) to perform automatic white and black balance adjustments. While the ATW function is operating (see the ATW in the AUTO FUNCTION menu on page 20), only automatic black balance adjustment is performed.|
|
||
|---|---|
|
||
|PRESET button|Press this button (which lights when pressed) to perform automatic black balance adjustment with using the preset white balance settings. While the ATW function is operating (see the ATW in the AUTO FUNCTION menu on page 20), only automatic black balance adjustment is performed.|
|
||
|MANUAL button|When this button is pressed and lit, the white and black balance can be manually adjusted.a) The white balance cannot be manually adjusted while the ATW function is operating (see the ATW in the AUTO FUNCTION menu on page 20).|
|
||
|WHITE (white balance) R knob WHITE (white balance) B knob|When the MANUAL button is lit, use this knob to adjust the R signal gain. When the MANUAL button is lit, use this knob to adjust the B signal gain.|
|
||
|
||
|
||
a)To manually adjust the black balance, use the BLACK/
|
||
FLARE R, G, and B knobs. See "5 Black balance
|
||
adjustment/flare correction block" on next page.
|
||
|
||
|
||
9
|
||
|
||
|
||
|
||
|
||
# Location and Function of Parts
|
||
|
||
|
||
5 Black balance adjustment/flare correction block
|
||
Use the buttons and knobs described below to perform
|
||
automatic or manual adjustment of black balance and
|
||
to perform flare correction.
|
||
The buttons and knobs operate differently according to
|
||
the connected camera.
|
||
|
||
|
||
## When using the DXC-D30/D30P:
|
||
|
||
|
||
## Name Operation
|
||
|
||
|
||
FLARE button Press this button (which lights when
|
||
pressed) to perform flare correction using
|
||
the BLACK/FLARE knobs when it is
|
||
allowed in the FLARE menu (see page
|
||
|
||
|
||
15).
|
||
|
||
|
||
BLACK AUTO Press this button (which lights when
|
||
(black balance pressed) to perform automatic black
|
||
auto adjust) balance adjustments.
|
||
button
|
||
BLACK When this button is pressed and lit, the
|
||
MANUAL (black black balance can be manually adjusted.
|
||
balance manual
|
||
adjust) button
|
||
BLACK FLARE When the BLACK MANUAL button is lit,
|
||
R knob use this knob to adjust the R signal level.
|
||
When the FLARE button is lit, use this
|
||
knob to perform flare correction of the R
|
||
signal.
|
||
BLACK FLARE When the BLACK MANUAL button is lit,
|
||
B knob use this knob to adjust the B signal level.
|
||
When the FLARE button is lit, use this
|
||
knob to perform flare correction of the B
|
||
signal.
|
||
BLACK FLARE When the BLACK MANUAL button is lit,
|
||
G knob use this knob to adjust the G signal level.
|
||
When the FLARE button is lit, use this
|
||
knob to perform flare correction of the G
|
||
signal.
|
||
|
||
|
||
## When using the DXC-637 series:
|
||
|
||
|
||
## Name Operation
|
||
|
||
|
||
|FLARE button|This button does not (because|
|
||
|---|---|
|
||
||manual flare correction is disallowed on|
|
||
||the DXC-637 series).|
|
||
|BLACK AUTO|This button does not operate.|
|
||
|auto||
|
||
|||
|
||
|button||
|
||
|BLACK MANUAL|This button does not operate.|
|
||
|balance adjustment)||
|
||
|button||
|
||
|BLACK R knob|When the MANUAL button in the white balance block 4 is lit, use|
|
||
||this knob to adjust the R signal level.|
|
||
|BLACK B knob|When the MANUAL button in the white balance block 4 is lit, use|
|
||
||this knob to adjust the B signal level.|
|
||
|BLACK G knob|When the MANUAL button in the white balance block 4 is lit, use|
|
||
||this knob to adjust the G signal level.|
|
||
|6 Iris Use the or manually|block buttons and knobs to automatically the iris setting.|
|
||
|Name|Operation|
|
||
|AUTO (auto|Press this button (which lights when|
|
||
|adjust) button|pressed) to activate auto iris function.|
|
||
|EXT indicator|Lights when a lens extender is used. (This indicator does not when|
|
||
||using the DXC-637 series).|
|
||
|Display|The current F-stop value is shown in this window. (When the DXC-637|
|
||
||series, only manual adjustment values|
|
||
||are shown.)|
|
||
|IRIS knob|Use this knob to manually adjust the iris|
|
||
||when the AUTO button is not lit. When|
|
||
||the AUTO button is lit, use this knob to|
|
||
||manually adjust the iris override.|
|
||
|COARSE (iris|Use this knob to coarsely adjust the iris|
|
||
|coarse adjust)|when the AUTO button is not lit. If the|
|
||
|knob|AUTO button is lit, use this knob to|
|
||
||manually adjust the iris override.|
|
||
|SENS|Use this knob to adjust how many|
|
||
|(sensitivity|rotations of the IRIS knob are required to|
|
||
|adjust) knob|set the full iris range from open to closed.|
|
||
||MIN: About four rotations|
|
||
||CENTER: About one rotation|
|
||
||MAX: About 1/2 rotation|
|
||
|
||
|
||
10
|
||
|
||
|
||
|
||
|
||
7 IRIS/M.BLACK LINK (iris/master black
|
||
adjustment link) button
|
||
Press this button (which lights when pressed) to
|
||
perform linked adjustments of iris and master black for
|
||
several cameras.
|
||
|
||
|
||
For details, see "Adjusting the Iris and Master Black of
|
||
Multiple Cameras at One Time" on page 27.
|
||
|
||
|
||
8 CALL button
|
||
Press this button (which lights when pressed) to light
|
||
the CALL button and red tally indicator on the camera,
|
||
CA, and CCU. This button lights when the unit
|
||
receives a tally signal from the CA or CCU.
|
||
|
||
|
||
9 Master black adjustment block
|
||
Use the knob to adjust the master black. During
|
||
adjustment, adjustment value is shown in the display
|
||
window here.
|
||
|
||
|
||
0 MASTER GAMMA knob
|
||
Use this knob to adjust the master gamma. During
|
||
adjustment, adjustment value is shown on the LCD
|
||
panel in the menu operation/setting display section 2.
|
||
|
||
|
||
!¡ DETAIL knob
|
||
Use this knob to adjust the master detail. During
|
||
adjustment, adjustment value is shown on the LCD
|
||
panel in the menu operation/setting display section 2.
|
||
|
||
|
||
!™ Shutter setting block
|
||
Use the buttons described below to set the shutter's
|
||
operation mode, speed, and CLS (clear scan)
|
||
frequency.
|
||
|
||
|
||
|Name|Operation|
|
||
|---|---|
|
||
|C. SCAN (clear scan) button|Press this button (which lights when pressed) to set the CLS frequency. This button does not operate when the TLCS (total level control system) is operating.|
|
||
|SHUTTER ON/ OFF button|Press this button (which lights when pressed) to set the shutter speed. This button does not operate when the camera's TLCS is operating.|
|
||
|4 (up) button|Each press of this button raises the CLS frequency or shutter speed setting value by one step. (The CLS frequency value changes continuously while the button is being pressed.) Press the up and down buttons simultaneously to select the minimum value.|
|
||
|$ (down) button|Each press of this button lowers the CLS frequency or shutter speed setting value by one step. (The CLS frequency value changes continuously while the button is being pressed.) Press the up and down buttons simultaneously to select the minimum value.|
|
||
|Display window|Displays the current CLS frequency when the C.SCAN button is lit. Displays the current shutter speed when the ON button is lit.|
|
||
|
||
|
||
11
|
||
|
||
|
||
|
||
|
||
|Men Location u and Operations Function of Parts|
|
||
|---|
|
||
|Displaying menus|
|
||
|
||
|
||
Press one of the menu selection buttons to have the
|
||
corresponding menu displayed in the LCD panel. To
|
||
access the AUTO SKIN menu (see peges 17 and 19),
|
||
however, press the AUTO SETUP SKIN DETAIL
|
||
button (see page 6).
|
||
The menus that correspond to the buttons are listed
|
||
below.
|
||
|
||
|
||
Most of menus consist of several pages which are
|
||
divided into two types: normal setting pages and
|
||
advanced setting pages. This unit is allowed to access
|
||
only normal setting pages when it is powered on.
|
||
To access advanced setting pages, follow the
|
||
procedure described below and set the unit to the
|
||
advanced setting mode.
|
||
|
||
|
||
# Setting the unit to the advanced setting mode
|
||
|
||
|
||
|||OPERATION PAINT||1,2 2|
|
||
|---|---|---|---|---|
|
||
|
||
|
||
1
|
||
|
||
|
||
Set the OPERATE knob to "PAINT".
|
||
|
||
|
||
"ADV>" appears on the LCD panel.
|
||
2 Set the OPERATE knob to "FULL" while pressing
|
||
down the setting button on the right of the
|
||
"ADV>" indication.
|
||
|
||
|
||
# Note
|
||
|
||
|
||
During menu operations, the message "ITEM NOT
|
||
AVAILABLE" appears on the LCD panel under the
|
||
following situations. Wait until the message
|
||
disappears and perform correct operations.
|
||
When using the DXC-D30/D30P, trying to access a
|
||
menu consisting of only advanced setting pages (such
|
||
as the GAMMA or SHADING menu) without setting
|
||
the unit to the advanced setting mode
|
||
When using the DXC-637 series, pressing a menu
|
||
selection button which does not operate for the DXC-
|
||
637 series (such as the DETAIL button)
|
||
|
||
|
||
12
|
||
|
||
|
||
|
||
|
||
|Button/menu title|Principle settings When using DXC-D30/D30P Normal settingsa)|Advanced settingsa)|When using DXC-637 series|
|
||
|---|---|---|---|
|
||
|DETAIL|Detail correction-1 (page 15)| Detail correction-2 (page 17) Aperture correction (page 17)|-|
|
||
|GAMMA|-|Gamma correction (page 18)|-|
|
||
|KNEE|Knee correction (page 15)|White clip circuit on/off (page 18)|Knee correction (page 19)|
|
||
|FLARE|Flare correction (page 15)|-|-|
|
||
|RECALL|Recall scene file/setup file (page 15)|-|Recall scene file (page 19)|
|
||
|STORE|Store scene file/setup file (page 15)|-|Store scene file (page 19)|
|
||
|SHADING|-|Shading correction (page 18)|-|
|
||
|MATRIX| Matrix adjustment-1 (page 16) Skin matrix adjustment (page 16)|Matrix adjustment-2 (page 18)|Matrix adjustment mode (page 19)|
|
||
|FILTER|Filter position indication (page 16)|-|-|
|
||
|LENS|Focus/zoom control (page 16)|-|Focus/zoom control (page 20)|
|
||
|PAN/TILT|Pan/tilt operation (page 16)|-|Pan/tilt operation (page 20)|
|
||
|SKIN GATE|Skin gate setting-1 (page 16)|Skin gate setting-2 (page 18)|-|
|
||
|SKIN DETAIL|Skin detail correction (page 16)|-|-|
|
||
|DYNA LATITUDE|DynaLatitude function (page 16)|-|-|
|
||
|BLACK STRETCHb)|Black stretch/compress-1 (page 16)|Black stretch/compress-2 (page 18)|-|
|
||
|TLCS (total level control system)|TLCS function (page 16)|-|-|
|
||
|AUTO FUNCTION| Auto iris mode (page 16) ATW function (page 16)|-| Auto iris mode (page 20) ATW function (page 20)|
|
||
|DIAG (diagnosis)|-|Displaying camera self- diagnosis results (page 18)|-|
|
||
|OTHERS| EVS/ECS (page 16) Camera ID (page 16) Clock indication (page 17) Center marker (page 17) Safety zone marker (page 17)| Data transfer (page 18) 1 kHz-tone signal (page 18) Color bars type (page 18) Screen mode display (page 18) Items set by command link operation (page 19)| EVS (page 20) Title (page 20) Clock indication (page 20) Advanced settingsa) Data transfer (page 20) Items set by command link operation (page 20)|
|
||
|AUTO SETUP SKIN DETAILC)| Automatic designation of the skin gate (page 17) Skin gate setting-1 (page 17)|Skin gate setting-2 (page 19)|-|
|
||
|
||
|
||
1. When the unit is set to the advanced setting mode, both the normal and advanced settings can be performed.
|
||
|
||
2. The menu title is "BLACK STR".
|
||
|
||
3. This button is not a menu selection button (see 6 AUTO SETUP buttons on page 6). The menu title is "AUTO SKIN".
|
||
|
||
4.
|
||
|
||
|
||
|
||
|
||
# Menu Operations
|
||
|
||
|
||
## Basic Menu Operations
|
||
|
||
|
||
## Changing pages
|
||
|
||
|
||
Press a menu selection button to display the first page
|
||
of the corresponding menu.
|
||
|
||
|
||
Menu title
|
||
|
||
|
||
## MENU TITLE <A
|
||
|
||
|
||
B>
|
||
|
||
|
||
<C D>
|
||
|
||
|
||
If your desired item is not on the first page, press the
|
||
NEXT button to go to the next page. You can also
|
||
change the pages by pressing the menu selection
|
||
button repeatedly.
|
||
To go back one page, press the PREV button.
|
||
Pressing both buttons simultaneously recalls the first
|
||
menu page.
|
||
When the unit is set to the advance setting mode (see
|
||
page 12), the advanced setting pages can be displayed
|
||
in addition to the normal setting pages.
|
||
|
||
|
||
## Using the knobs and buttons
|
||
|
||
|
||
Three knobs and four buttons are used to make settings
|
||
via menu operations.
|
||
The following figure shows how these knobs and
|
||
buttons are used.
|
||
|
||
|
||
How to use the buttons
|
||
Functions of the buttons vary according to menu.
|
||
|
||
|
||
Example: KNEE menu (KNEE MODE setting
|
||
page)
|
||
|
||
|
||
||Setting buttons||
|
||
|---|---|---|
|
||
||||
|
||
|
||
|
||
KNEE
|
||
<PRESET
|
||
MANUAL KNEE
|
||
<VARIABLE
|
||
|
||
|
||
VARIABLE button: Not lit
|
||
|
||
|
||
PRESET button: Lit
|
||
|
||
|
||
In this case, the upper left button operates as PRESET
|
||
button, and the lower left button operates as
|
||
VARIABLE button. The PRESET button is lit because
|
||
the preset mode is currently selected.
|
||
Press the VARIABLE button to select the variable
|
||
mode.
|
||
|
||
|
||
How to use the knobs
|
||
Functions of the knobs vary according to menu.
|
||
|
||
|
||
Example: DETAIL menu
|
||
Adjustment value set
|
||
by FREQ knob
|
||
|
||
|
||
||DETAIL H/V +01|
|
||
|---|---|
|
||
|FREQ|H/V knob|
|
||
|
||
|
||
Adjustment value set
|
||
by H/V knob
|
||
|
||
|
||
14
|
||
|
||
|
||
In this case, the left knob operates as FREQ
|
||
(frequency) knob, and the right knob operates as H/V
|
||
knob.
|
||
To set the frequency, turn the FREQ knob. To set the
|
||
H/V, turn the H/V knob.
|
||
|
||
|
||
|
||
|
||
# Note
|
||
|
||
|
||
The adjustment values displayed on the LCD panel
|
||
may be relative values (not real values). Slight turn of
|
||
a knob sometimes causes undesirable sudden change
|
||
of values.
|
||
Even in the case that they are real values, values may
|
||
change while they are transferred to the camera.
|
||
|
||
|
||
## Menu Contents
|
||
|
||
|
||
The contents of each menu, which vary according to
|
||
the camera, are listed in the table below.
|
||
|
||
|
||
|Menu title|Knob/button|Setting or operation|
|
||
|---|---|---|
|
||
|DETAIL|FREQ knob: LL/M/H/HH H/V knob: -99 to 00 to 99|Boost frequency for the detail correction Ratio of V (vertical) detail to H (horizontal) detail (As the value becomes larger, the V detail ratio increases.)|
|
||
|KNEE (1/2)|PRESET button VARIABLE button|Setting the knee point (level at which the knee correction starts) and knee slope (amount of the knee correction) manually using the preset values (see page 9). Setting the knee point and knee slope manually (see page 9). Values can be set by the knob in the knee correction block or the POINT and SLOPE knobs on page 2/2 of the KNEE menu.|
|
||
|KNEE (2/2)|POINT knob: -99 to 00 to 99 SLOPE knob: -99 to 00 to 99|Knee point (As the value becomes larger, the start level lowers, which enhances the knee correction effect.) Knee slope|
|
||
|FLARE|ON/OFF buttons RED/GREEN/BLUE knobs: -99 to 00 to 99|Select whether or not you will perform flare correction. Amounts of flare correction for R, G and B signals.|
|
||
|RECALL (1/2) See page 23 for details.|SCENE F. RECALL button SEL knob: USR01 to USR16|Press to recall a scene file stored in this unit's memory. Select a scene file that you will recall.|
|
||
|RECALL (2/2) See page 24 for details.|SETUP F. RECALL button SEL knob: PRE1 to PRE5 and USR1 to USR3|Press to recall a setup file stored in the camera's memory. Select a setup file that you will recall.|
|
||
|STORE (1/2) See page 23 for details.|SCENE F. STORE button CUR knob SEL knob: USR01 to USR16 CHR knob:|Press to store a scene file onto this unit's memory. Use the SEL knob to number the file. Move the cursor to enter a file name (eight characters). Select a number for the file that you will store. Select characters to enter a file name.|
|
||
|STORE (2/2) See page 24 for details.|SETUP F. STORE button CUR knob SEL knob: USR1 to USR3 CHR knob:|Press to store a setup file onto the camera's memory. Use the SEL knob to number the file. Move the cursor to enter a file name (eight characters). Select a number for the file that you will store. Select characters to enter a file name.|
|
||
|
||
|
||
## When using the DXC-D30/D30P
|
||
|
||
|
||
The list for the case of using the DXC-637 series is on page
|
||
|
||
|
||
19.
|
||
|
||
|
||
## Normal setting pages
|
||
|
||
|
||
Underlined values or settings are selected at the
|
||
shipping of the camera.
|
||
|
||
|
||
See page 17 for advanced setting pages.
|
||
|
||
|
||
(continued)
|
||
|
||
|
||
15
|
||
|
||
|
||
|
||
|
||
# Menu Operations
|
||
|
||
|
||
|Menu title|Knob/button|Setting or operation|
|
||
|---|---|---|
|
||
|MATRIX (1/2)|ON/OFF buttons SAT/HUE knobs: -99 to 00 to +99|Select whether or not you will perform linear matrix adjustment. Saturation and hue|
|
||
|MATRIX (2/2: SKIN)|ON/OFF buttons SAT/HUE knob: -99 to 00 to +99|Select whether or not you will perform matrix adjustment of the skin gate area. Saturation and hue of the skin gate area|
|
||
|FILTER|-|Displays the current filter position (1, 2, 3, or 4).|
|
||
|LENSa)|ON/OFF buttons FOCUS knob: -99 to 00 to +99 ZOOM knob: -99 to 00 to +99|Activate optional control function 1 or not. Focus Zoom|
|
||
|PAN/TILTb)|ON/OFF buttons PAN knob: -99 to 00 to +99 TILT knob: -99 to 00 to +99|Activate optional control function 2 or not. Rotation of the tripod head Tilt of the tripod head|
|
||
|SKIN GATE (1/2)|ON/OFF buttons GATE SIZE knob: -99 to 00 to +99|Select whether or not you will display the skin gate area (color range designated as skin tone) using the PIX output from the CCU-TX7/7P. R-Y and B-Y ranges of the skin gate area (for setting each range to the same value at the same time)|
|
||
|SKIN GATE (2/2: SIZE)|R-Y knob: -99 to 00 to +99 B-Y knob: -99 to 00 to +99|R-Y range of the skin gate area B-Y range of the skin gate area|
|
||
|SKIN DETAIL|LEVEL knob: -99 to 00 to +99|Amount of skin detail correction (As the value becomes larger, the detail level lowers.)|
|
||
|DYNA LATITUDE|OFF button LOW/MID/HI buttons|Do not use the DynaLatitude function. Select the DynaLatitude level.|
|
||
|BLACK STR|LEVEL knob: -99 to 00 to +99|Black stretch level|
|
||
|TLCS|ON/OFF button AGC knob: F5.6/F4/F2.8/F1.8 GAIN knob: 0/3/6/9/12dB AE knob: F5.6/F8/F11/F16|Select whether or not you will use the TLCS (total level control system) function. F-stop value at which the auto iris control is switched to the AGC (auto gain control) Upper limit value for the AGC F-stop value at which the auto iris control is switched to the AE (auto exposure).|
|
||
|AUTO FUNCTION (1/2: ATW)|ON/OFF buttons|Select whether or not you will use the ATW (auto tracing white balance) function.|
|
||
|AUTO FUNCTION (2/2: A.IRIS MODE)|STD button SPOT.L button AI button BACK.L button|Standard auto iris mode Auto iris mode for shooting spot-lit subjects Intelligent auto iris mode Auto iris mode for shooting back-lit subjects|
|
||
|OTHERS (1/6: SHUTTER)|EVS button|Set the shutter to the EVS mode. If you do not use the EVS mode, set the C.SCAN button or SHUTTER ON/OFF button to ON in the shutter setting block !™ (see page 11).|
|
||
|OTHERS (2/6: CAM ID SET)|CUR knob CHR knob|Move the cursor to enter a camera ID (eight characters). Select characters to enter a camera ID (alphanumerics, symbols, and space).|
|
||
|OTHERS (3/6: CAM ID IND)|ON/OFF buttons|Select whether or not you will display a camera ID.|
|
||
|
||
|
||
16
|
||
|
||
|
||
|
||
|
||
|Menu title|Knob/button|Setting or operation|
|
||
|---|---|---|
|
||
|OTHERS (4/6: CLOCK IND)|CAM button OFF button BARS button|Display the date/time. Do not display the date/time. Display the date/time only when camera color bars are displayed.|
|
||
|OTHERS (5/6: CENTER MARKER)|ON/OFF buttons|Select whether or not you will display the center marker.|
|
||
|OTHERS (6/6: SAFETY ZONE)|80%/90% buttons OFF button|Select safety zone marker size. Do not display the safety zone marker.|
|
||
|AUTO SKIN c)|GATE SIZE knob: -99 to 00 to +99|R-Y and B-Y ranges of the skin gate area (for setting each range to the same value at the same time)|
|
||
|
||
|
||
(not supplied) and camera adaptor interface unit for lens control
|
||
|
||
|
||
# a) Lens control requires a focus and zoom servo interface unit (not supplied).
|
||
|
||
|
||
b) Use an electrical tripod head for remote pan/tilt operation. A camera adaptor interface unit for tripod head control (not
|
||
supplied) is required.
|
||
|
||
|
||
# c) This menu is recalled with the AUTO SETUP SKIN DETAIL button on page 6.
|
||
|
||
|
||
# Advanced setting pages
|
||
|
||
|
||
For each menu, the advanced setting pages as
|
||
described below are displayed in addtition to the
|
||
normal setting pages (listed on page 15). In this menu
|
||
display mode, the page numbering system is serial,
|
||
|
||
|
||
|Menu title|Knob/button|Setting or operation|
|
||
|---|---|---|
|
||
|DETAIL (2/8)|ON/OFF buttons|Select whether or not you will perform detail correction.|
|
||
|DETAIL (3/8)|CRISP knob: -99 to 00 to +99 (Factory setting: -96) LEV DEP knob: -99 to 00 to +99 (Factory setting: 63) V-DTL LIMIT knob: -99 to 00 to +99 (Factory setting: -71)|Crispening level (at which details of noise signals are removed) Level dependence (level at which the detail signal starts being suppressed.) Limit value of the vertical detail|
|
||
|DETAIL (4/8)|HIGHLIGHT knob: -99 to 00 to +99 AFTER GAMMA knob: -99 to 00 to +99 (Factory setting: -71)|Highlight detail (amount of detail suppression to highlight areas) Amount of detail added after gamma correction|
|
||
|DETAIL (5/8: APERTURE)|ON/OFF buttons LEVEL knob: -99 to 00 to +99|Select whether or not you will perform aperture correction. Amount of aperture correction|
|
||
|DETAIL (6/8: KNEE APERTURE)|ON/OFF buttons LEVEL knob: -99 to 00 to +99 (Factory setting: 51)|Select whether or not you will perform detail correction to the levels higher than the knee point. Amount of the detail correction to the levels higher than the knee point.|
|
||
|DETAIL (7/8: CROSS COLOR SUPPRESS)|CROSS COLOR SUPPRESS knob: -99 to 00 to +99|Amount of cross color suppression|
|
||
|DETAIL (8/8: COMB FILTER)|RED ON/OFF buttons GRN ON/OFF buttons|Select whether or not you will activate the red comb filter in the detail circuit. If you select OFF, clarity improves but cross color increases. Select whether or not you will activate the green comb filter in the detail circuit. If you select OFF, clarity improves but cross color increases.|
|
||
|GAMMA (1/2)|ON/OFF buttons RED/BLUE knobs: -99 to 00 to +99 MAST knob: -99 to 00 to +99|Select whether or not you will perform gamma correction. Amount of R and B gamma Amount of master gamma|
|
||
|
||
|
||
that is, the total number refers to the sum of both
|
||
normal and advanced setting pages.
|
||
Underlined values or settings are selected as factory
|
||
settings for the camera. (Factory settings are otherwise
|
||
indicated in some menus.)
|
||
|
||
|
||
(continued)
|
||
|
||
|
||
17
|
||
|
||
|
||
|
||
|
||
# Menu Operations
|
||
|
||
|
||
|Menu title|Knob/button|Setting or operation|
|
||
|---|---|---|
|
||
|GAMMA (2/2: GAMMA INIT GAIN)|3.5/4.0 buttons|Select the slope of the initial part of the gamma curve for low-brightness.|
|
||
|KNEE (3/3: WHITE CLIP)|ON/OFF buttons LEVEL knob: -99 to 00 to +99|Select whether or not you will activate the white clip circuit. Amount of white clip (As the value becomes larger, the output level lowers.)|
|
||
|SHADING (WHITE V SAW)|RED/GREEN/BLUE knobs: -99 to 00 to +99|Amount of vertical white shading for R, G and B signals|
|
||
|MATRIX (3/4)|R-G knob: -99 to 00 to +99 (Factory setting: +65 for DXC-D30 or +38 for DXC-D30P ) B-G knob: -99 to 00 to +99 (Factory setting: +28 for DXC-D30 or +22 for DXC-D30P ) G-R knob: -99 to 00 to +99 (Factory setting: +31 for DXC-D30 or +12 for DXC-D30P )|R-G level of the linear matrix R-B level of the linear matrix G-R level of the linear matrix|
|
||
|MATRIX (4/4)|G-B knob: -99 to 00 to +99 (Factory setting: +32 for DXC-D30 or +15 for DXC-D30P ) B-R knob: -99 to 00 to +99 (Factory setting: +22 for DXC-D30 or +12 for DXC-D30P ) B-G knob: -99 to 00 to +99 (Factory setting: +6 for DXC-D30 or +15 for DXC-D30P )|G-B level of the linear matrix B-R level of the linear matrix B-G level of the linear matrix|
|
||
|SKIN GATE (3/3)|POSI R-Y/B-Y knobs: -99 to 00 to +99|R-Y and B-Y levels of the skin gate|
|
||
|BLACK STR (2/3: STRETCH LEVEL)|POINT 1 knob: -99 to 00 to +99 (Factory setting: -39) POINT 2 knob: -99 to 00 to +99 (Factory setting: -41)|Lower limit of the signal levels which activate the black stretch function Upper limit of the signal levels which activate the black stretch function|
|
||
|BLACK STR (3/3: COMPRESS LEVEL)|POINT 1 knob: -99 to 00 to +99 (Factory setting: -77) POINT 2 knob: -99 to 00 to +99|Lower limit of the signal levels which activate the black compress function Upper limit of the signal levels which activate the black compress function|
|
||
|DIAG|RESET button REQ button|Reset (erase) the camera's self-diagnosis data. Press to request camera's self-diagnosis data. If an abnormality has been detected, the data will be transferred to the RCP and displayed. Change the menu page to change data indications. (If there is no abnormality, no data will be displayed.)|
|
||
|OTHERS (2/11: COPY TO SLAVES) For details, see page 27.|COPY TO SLAVES button|Copy the settings of the master unit to the slave units.|
|
||
|OTHERS (8/11: TONE/ BARS TYPE)|ON/OFF buttons BARS TYPE knob: SMPTE/SNG/FULL FIELD 75%/FULL FIELD 100%(For DXC-D30) or SPLIT/SNG/EBU 75%/ EBU 100% (For DXC-D30P)|Select whether or not you will allow the camera to output a 1-kHz audio signal when color bars are displayed. Select color bars output from the camera (not from the CCU-TX7/7P).|
|
||
|OTHERS (9/11: SCREEN MODE)|-|Display the screen mode (4:3).|
|
||
|
||
|
||
18
|
||
|
||
|
||
|
||
|
||
|Menu title|Knob/button|Setting or operation|
|
||
|---|---|---|
|
||
|OTHERS (10/11: COMM LINK|GAIN button|Activate command link operation of gain setting among several cameras.|
|
||
|For details, see 27.|SHUTTER button|Activate command link operation of shutter setting among several cameras.|
|
||
|OTHERS (11/11: COMM LINK|WHITE button|Activate command link operation of manual white balance adjustment among several cameras.|
|
||
|see 27.|BLACK button|Activate command link operation of manual black balance adjustment among several cameras.|
|
||
||FLARE button|Activate command link of manual flare correction|
|
||
|||among several cameras.|
|
||
|AUTO SKIN (2/3) a)|ON/OFF buttons|Select whether or not will the window|
|
||
|||the skin on the viewfinder screen. (When the AUTO|
|
||
|||SKIN menu is recalled, the ON button is|
|
||
|||selected.)|
|
||
||V-POSI knob: -99 to 00 +99|Vertical position of the window|
|
||
|AUTO SKIN (3/3) a)|ON/OFF buttons|Select whether or not will the window|
|
||
|||the skin on the viewfinder screen. (When the AUTO|
|
||
|||SKIN menu is recalled, the ON button is|
|
||
|||selected.)|
|
||
||WIDTH knob: -99 to 00 +99 HEIGHT knob: -99 to 00|Width of the window Height of the window|
|
||
|a) This menu is|with the AUTO SETUP|button on page 6. DETAIL|
|
||
|When using Only the pages.|DXC-637 series menu contains the advanced|Underlined values or settings are selected at the shipping of the camera.|
|
||
|Menu title|Knob/button|Setting or operation|
|
||
|KNEE (1/2)|PRESET button|the knee (level at which the knee correction|
|
||
|||starts) manually using the preset values (see page 9).|
|
||
||VARIABLE button|the knee (see 9). A value can|
|
||
|||be set the knob in the knee correction block or the|
|
||
|||MANUAL KNEE knob on page 2/2 of the KNEE menu.|
|
||
|KNEE (2/2)|MANUAL KNEE knob:|Knee (As the value becomes the start level|
|
||
||-99 to 00 to +99|lowers, which enhances the knee correction effect.)|
|
||
|RECALL|SCENE F. RECALL button|Press to recall a scene file stored in this unit's memory.|
|
||
|details.|SEL knob: USR01 to|Select a scene file that you will recall.|
|
||
|STORE|SCENE F. STORE button|Press to store a scene file onto this unit's Use the|
|
||
|See page 23 for||SEL knob to number the file.|
|
||
|details.|CUR knob|Move the cursor to enter a file name (eight characters).|
|
||
||CHR knob:|Select characters to enter a file name.|
|
||
|MATRIX|STD/FL/H.SAT buttons|Select color matrix mode.|
|
||
|||STD: standard|
|
||
|||FL: for under fluorescent|
|
||
|||H.SAT: saturation the saturation of|
|
||
|||colors)|
|
||
|
||
|
||
(continued)
|
||
|
||
|
||
19
|
||
|
||
|
||
|
||
|
||
# Menu Operations
|
||
|
||
|
||
|Menu title|Knob/button|Setting or operation|
|
||
|---|---|---|
|
||
|LENSa)|ON/OFF buttons FOCUS knob: -99 to 00 to +99 ZOOM knob: -99 to 00 to +99|Activate optional control function 1 or not. Focus Zoom|
|
||
|PAN/TILTb)|ON/OFF buttons PAN knob: -99 to 00 to +99 TILT knob: -99 to 00 to +99|Activate optional control function 2 or not. Rotation of the tripod head Tilt of the tripod head|
|
||
|AUTO FUNCTION (1/2: ATW)|ON/OFF buttons|Select whether or not you will use the ATW (auto tracing white balance) function.|
|
||
|AUTO FUNCTION (2/2: A.IRIS MODE)|STD button SPOT.L button BACK.L button|Standard auto iris mode Auto iris mode for shooting spot-lit subjects Auto iris mode for shooting back-lit subjects|
|
||
|OTHERS (1/3: EVS)|EVS button|Set the shutter to the EVS mode. If you do not use the EVS mode, set the C.SCAN button or SHUTTER ON/OFF button to ON in the shutter setting block !™ (see page 11).|
|
||
|OTHERS (2/3: TITLE IND)|ON/OFF buttons|Select whether or not you will display the title set on the camera.|
|
||
|OTHERS (3/3: CLOCK IND)|ON/OFF buttons|Select whether or not you will display the date and time.|
|
||
|
||
|
||
a)Lens control requires a focus and zoom servo interface unit (not supplied) and camera adaptor interface unit for lens contrtol
|
||
(not supplied).
|
||
|
||
|
||
b)Use an electrical tripod head for remote pan/tilt operation. A camera adaptor interface unit for tripod head control (not
|
||
supplied) is required.
|
||
|
||
|
||
## Advanced setting pages (OTHERS menu)
|
||
|
||
|
||
The following advanced setting pages are displayed in
|
||
addition to the normal setting pages. In this menu
|
||
|
||
|
||
|Menu title|Knob/button|Setting or operation|
|
||
|---|---|---|
|
||
|OTHERS (4/6: COPY TO SLAVES) For details, see page 27.|COPY TO SLAVES button|Copy the settings of the master unit to the slave units.|
|
||
|OTHERS (5/6: COMM LINK ITEM-1) For details, see page 27.|GAIN button SHUTTER button|Activate command link operation of gain setting among several cameras. Activate command link operation of shutter setting among several cameras.|
|
||
|OTHERS (6/6: COMM LINK ITEM-2) For details, see page 27.|WHITE button BLACK button|Activate command link operation of manual white balance adjustment among several cameras. Activate command link operation of manual black balance adjustment among several cameras.|
|
||
|
||
|
||
display mode, the page numbering system is serial,
|
||
that is, the total number refers to the sum of both
|
||
normal and advanced setting pages.
|
||
|
||
|
||
20
|
||
|
||
|
||
|
||
|
||
|File Operations|
|
||
|---|
|
||
||
|
||
|
||
|
||
This unit can operate two types of files: scene files and
|
||
setup files.
|
||
Setting data of cameras can be registered as scene files
|
||
or setup files and recalled as required. (For the DXC-
|
||
|
||
|
||
|Setting item|DXC-D30/D30P Setup file|Scene file|DXC-637 series Scene file|
|
||
|---|---|---|---|
|
||
|Selecting shooting picture or color bars||OK|OK|
|
||
|Master black|OK|OK|OK|
|
||
|Iris||OK|OK|
|
||
|Auto iris mode||OK|OK|
|
||
|Master gain||OK|OK|
|
||
|TLCS||OK||
|
||
|Upper limit value for AGC||OK||
|
||
|Initial F-stop value for AGC||OK||
|
||
|Initial F-stop value for AE||OK||
|
||
|Shutter/Clear scan||OK|OK|
|
||
|Shutter speed||OK|OK|
|
||
|Clear scan frequency||OK|OK|
|
||
|Filter position||OK||
|
||
|Selecting white balance or black balance adjustment|OK|OK||
|
||
|ATW on/off||OK|OK|
|
||
|R/B white balance adjustment||OK|OK|
|
||
|R/B black balance adjustment||OK|OK|
|
||
|Flare correction on/off||OK||
|
||
|R/G/B flare correction||OK||
|
||
|Detail correction on/off||OK||
|
||
|Detail level|OK|OK|OK|
|
||
|Detail boost frequency|OK|OK||
|
||
|Crispening level|OK|OK||
|
||
|Level dependence value|OK|OK||
|
||
|Detail H/V|OK|OK||
|
||
|V-detail limit value|OK|OK||
|
||
|Highlight detail|OK|OK||
|
||
|After gamma detail|OK|OK||
|
||
|Aperture correction on/off||OK||
|
||
|Aperture correction value|OK|OK||
|
||
|Knee aperture correction on/off||OK||
|
||
|Knee aperture correction value|OK|OK||
|
||
|Cross color suppress value|OK|OK||
|
||
|R/G comb filter on/off|OK|OK||
|
||
|Knee correction mode||OK|OK|
|
||
|Master knee point|OK|OK|OK|
|
||
|Master knee slope|OK|OK||
|
||
|White clip circuit on/off||OK||
|
||
|White clip value||OK||
|
||
|Gamma correction on/off||OK||
|
||
|
||
|
||
637 series camera, only scene files are available.)
|
||
The table below shows the setting items which can be
|
||
registered as either of the files.
|
||
|
||
|
||
(continued)
|
||
|
||
|
||
21
|
||
|
||
|
||
|
||
|
||
# File Operations
|
||
|
||
|
||
|Setting item|DXC-D30/D30P Setup file|Scene file|DXC-637 series Scene file|
|
||
|---|---|---|---|
|
||
|Master gamma|OK|OK||
|
||
|R/B gamma||OK||
|
||
|Gamma initial gain|OK|OK||
|
||
|Black stretch level|OK|OK||
|
||
|Upper/lower limit value for black stretch|OK|OK||
|
||
|Upper/lower limit value for black compress|OK|OK||
|
||
|DynaLatitude effect||OK||
|
||
|Matrix adjustment on/off||OK||
|
||
|Saturation/hue|OK|OK||
|
||
|Matrix adjustment mode|||OK|
|
||
|Matrix parameter (R-G, R-B, G-R, G-B, B-R, B-G)|OK|OK||
|
||
|Skin detail level||OK||
|
||
|Skin matrix saturation/hue|OK|OK||
|
||
|Skin gate position/size||OK||
|
||
|Position/size of skin gate detect window||OK||
|
||
|Focus/zoom||OK|OK|
|
||
|Pan/tilt||OK|OK|
|
||
|On/off selection of optional control 1 or 2||OK|OK|
|
||
|
||
|
||
22
|
||
|
||
|
||
|
||
|
||
|||
|
||
|---|---|
|
||
|
||
|
||
# Operating Scene Files
|
||
|
||
|
||
Scene files are stored in the memory of the RCP.
|
||
Perform the following procedure to recall or store
|
||
scene files.
|
||
|
||
|
||
## Recalling a scene file
|
||
|
||
|
||
1
|
||
|
||
|
||
Use the RECALL menu in the following way.
|
||
|
||
|
||
File number
|
||
|
||
|
||
File namea)
|
||
|
||
|
||
STORE
|
||
SCENE F. STORE>
|
||
USR03
|
||
CUR SEL CHR
|
||
|
||
|
||
4
|
||
3
|
||
|
||
|
||
1
|
||
|
||
|
||
RECALL
|
||
SCENE F. RECALL>
|
||
USR03 file name
|
||
SEL
|
||
|
||
|
||
2
|
||
|
||
|
||
3
|
||
2
|
||
|
||
|
||
1
|
||
|
||
|
||
Press the STORE button to access the STORE
|
||
menu.
|
||
|
||
|
||
2
|
||
|
||
|
||
1
|
||
|
||
|
||
2
|
||
|
||
|
||
a) File names are displayed only for registered files.
|
||
|
||
|
||
Press the RECALL button to access the RECALL
|
||
menu.
|
||
|
||
|
||
Turn the SEL knob to search the number (USR01
|
||
to USR16) of the file which you will recall.
|
||
|
||
|
||
If the selected file is one of the registered files, the
|
||
file name appears on the right of the file number.
|
||
|
||
|
||
3
|
||
|
||
|
||
Press the SCENE F. RECALL button.
|
||
|
||
|
||
The settings of the camera are replaced by the data
|
||
of the recalled file.
|
||
|
||
|
||
## Note
|
||
|
||
|
||
If you recall an unregistered file, it is impossible to
|
||
assure whether the camera will be set up correctly or
|
||
not. Recall a file once registered.
|
||
|
||
|
||
## Storing a scene file
|
||
|
||
|
||
File number
|
||
|
||
|
||
Cursor
|
||
|
||
|
||
Use the STORE menu in the following way.
|
||
|
||
|
||
Turn the SEL knob and select a file number
|
||
(USR01 to USR16) which you will apply to the
|
||
current settings of the camera.
|
||
|
||
|
||
A cursor appears on the right of the number. If the
|
||
selected number has already been used for another
|
||
data, a file name also appears.
|
||
|
||
|
||
3 Enter a file name (eight characters).
|
||
Moving the cursor: Turn the CUR knob until the
|
||
cursor comes to the position where you will
|
||
enter a character.
|
||
Selecting a character: Turn the CHR knob until a
|
||
character which you will enter appears.
|
||
|
||
|
||
Press the SCENE F. STORE button.
|
||
|
||
|
||
4
|
||
|
||
|
||
The current settings of the camera are stored as a
|
||
scene file.
|
||
|
||
|
||
23
|
||
|
||
|
||
|
||
|
||
# File Operations
|
||
|
||
|
||
|||
|
||
|---|---|
|
||
|
||
|
||
# Operating Setup Files (for DXC- D30/D30P only)
|
||
|
||
|
||
Setup files are stored in the memory of the camera.
|
||
Perform the following procedure to recall or store
|
||
setup files.
|
||
|
||
|
||
1
|
||
|
||
|
||
## Recalling a setup file
|
||
|
||
|
||
Use the RECALL menu in the following way.
|
||
|
||
|
||
STORE 2/2
|
||
SETUP F. STORE>
|
||
USR3
|
||
CUR SEL CHR
|
||
|
||
|
||
File number
|
||
|
||
|
||
4
|
||
3
|
||
|
||
|
||
File name a)
|
||
|
||
|
||
1
|
||
|
||
|
||
2
|
||
|
||
|
||
RECALL 2/2
|
||
SETUP F. RECALL>
|
||
USR3 file name
|
||
SEL
|
||
|
||
|
||
3
|
||
2
|
||
|
||
|
||
## 1 Press the STORE button to access the STORE menu (page 2/2).
|
||
|
||
|
||
2
|
||
|
||
|
||
Turn the SEL knob and select a file number (USR1
|
||
to USR3) which you will apply to the current
|
||
settings of the camera.
|
||
|
||
|
||
a) For files numbered PRE1 to PRE5, no file names are
|
||
displayed until step 3 is performed.
|
||
|
||
|
||
1
|
||
|
||
|
||
2
|
||
|
||
|
||
3
|
||
|
||
|
||
Press the RECALL button to access the RECALL
|
||
menu (page 2/2).
|
||
|
||
|
||
Turn the SEL knob to search the number and name
|
||
of the file which you will recall. Preset files 1 to 5
|
||
(PRE1 to PRE5) and user setup files 1 to 3 (USR1
|
||
to USR3) are available.
|
||
|
||
|
||
Press the SETUP F. RECALL button.
|
||
|
||
|
||
The settings of the camera are replaced by the data
|
||
of the recalled file.
|
||
|
||
|
||
## Storing a setup file
|
||
|
||
|
||
File number
|
||
|
||
|
||
Cursor
|
||
|
||
|
||
Use the STORE menu in the following way.
|
||
|
||
|
||
A cursor appears on the right of the number. If the
|
||
selected number has already been used for another
|
||
data, a file name also appears.
|
||
|
||
|
||
Enter a file name (eight characters).
|
||
Moving the cursor: Turn the CUR knob until the
|
||
cursor comes to the position where you will
|
||
enter a character.
|
||
Selecting a character: Turn the CHR knob until a
|
||
character which you will enter appears.
|
||
|
||
|
||
3
|
||
|
||
|
||
## 4 Press the SETUP F. STORE button. The current settings of the camera are stored as a setup file.
|
||
|
||
|
||
24
|
||
|
||
|
||
|
||
|
||
|Skin Detail Correction/Skin Matrix Adjustment (for DXC-D30/D30P|
|
||
|---|
|
||
||
|
||
|
||
|
||
The skin detail and skin matrix functions can adjust
|
||
detail level and matrix (saturation and hue) of a
|
||
selected skin gate area (area designated by color
|
||
range).
|
||
Once a skin gate area has been selected, it can be used
|
||
as a target for both skin detail correction and skin
|
||
matrix adjustment, and activation of each function can
|
||
be performed independently.
|
||
|
||
|
||
## Selecting the skin gate area
|
||
|
||
|
||
Normally, use the AUTO SETUP SKIN DETAIL
|
||
button (see page 6) to designate the skin gate position
|
||
(target color) automatically.
|
||
|
||
|
||
## 1 Press and set the AUTO SETUP SKIN DETAIL button to on.
|
||
|
||
|
||
2
|
||
|
||
|
||
The AUTO SKIN menu appears on the LCD panel,
|
||
and the window which shows the skin gate and
|
||
target area appears in the camera's viewfinder.
|
||
You can see the skin gate with a picture output
|
||
from the CCU's PIX connector.
|
||
|
||
|
||
Press the AUTO SETUP SKIN DETAIL button
|
||
again.
|
||
|
||
|
||
3
|
||
|
||
|
||
The skin gate is designated automatically.
|
||
You can manually adjust the position of the
|
||
designated skin gate in the SKIN GATE menu
|
||
(page 3/3, advanced setting page)
|
||
|
||
|
||
Set the size of the skin gate area (target color
|
||
range) manually using the SKIN GATE menus if
|
||
necessary.
|
||
Using page 1/3 of the AUTO SKIN or of the
|
||
SKIN GATE menu: You can adjust the R-Y
|
||
and B-Y ranges to the same value at the same
|
||
time.
|
||
Using page 2/3 of the SKIN GATE menu: You
|
||
can adjust the R-Y and B-Y ranges
|
||
independently.
|
||
|
||
|
||
## Performing skin detail correction
|
||
|
||
|
||
By skin detail correction, you can lower the detail
|
||
level of the skin gate area to the detail level outside of
|
||
the area.
|
||
|
||
|
||
## 1 Press and set the SKIN DETAIL button to on (see page 8).
|
||
|
||
|
||
2 Use the LEVEL knob in the SKIN DETAIL menu
|
||
to set the detail correction level.
|
||
Setting the level to the max. value (+99): The
|
||
detail level of the area is set to the lowest level.
|
||
Setting the level to the min. value (-99): The
|
||
detail level of the area is set to the same level
|
||
with the outside of the area. (The same situation
|
||
as the skin detail function is set to off.)
|
||
|
||
|
||
If you power off the unit or store the current
|
||
settings as a scene file while setting the detail level
|
||
to -99, the skin detail function will be set to off
|
||
when you power on the unit or recall the scene file
|
||
next time.
|
||
|
||
|
||
To store the skin detail settings
|
||
Set the SKIN DETAIL button on before powering off
|
||
the unit or storing the settings as a scene file. If the
|
||
button is off, the skin detail settings will not be stored.
|
||
|
||
|
||
## Performing skin matrix adjustment
|
||
|
||
|
||
Follow the procedure described below to adjust the
|
||
matrix (saturation and hue) of the skin gate area.
|
||
|
||
|
||
1 Select the ON button on both pages 1/2 and 2/2 of
|
||
the MATRIX menu.
|
||
(Be sure to activate the matrix adjustment function
|
||
on page 1/2.)
|
||
|
||
|
||
## 2 Use the SATURATION and HUE knobs in page 2/2 of the MATRIX menu to adjust the saturation and hue.
|
||
|
||
|
||
Selecting 00 causes the same situation as the skin
|
||
matrix function is set off.
|
||
If you power off the unit or store the current
|
||
settings as a scene file while selecting 00, the skin
|
||
matrix function will be set to off when you power
|
||
on the unit or recall the scene file next time.
|
||
|
||
|
||
To store the skin matrix settings
|
||
Activate both the matrix adjustment and skin matrix
|
||
adjustment functions before powering off the unit or
|
||
storing the settings as a scene file. Otherwise, the skin
|
||
matrix settings will not be stored.
|
||
|
||
|
||
25
|
||
|
||
|
||
|
||
|
||
|Skin Multi-Camera Detail Correction/Skin Control Matrix Adjustment (for DXC-D30/D30P)|
|
||
|---|
|
||
||
|
||
|
||
|
||
In a multi-camera system, connecting all the CCUs via
|
||
the RS232C connectors allows one RCP unit selected
|
||
from all the RCP units in the system to control the
|
||
multiple cameras.
|
||
If the selected unit is set as the master unit and the rest
|
||
are set as slave units, the setting data of the camera
|
||
connected to the master unit can be transferred to other
|
||
cameras.
|
||
|
||
|
||
# To make connections among the CCUs
|
||
|
||
|
||
Connect RS-232C cross (or reverse) cables with D-sub
|
||
|
||
|
||
25-pin plugs (not supplied) to the RS232C connectors
|
||
|
||
|
||
on each CCU to make a daisy chain of the CCUs.
|
||
|
||
|
||
For more information about cables which can be used,
|
||
consult your Sony dealer.
|
||
|
||
|
||
# Notes
|
||
|
||
|
||
- It is impossible to assure that all the cameras can be set up to the same conditions under the multi-camera control. Setting purposes and the current condition of each camera may cause variation of the setting condition.
|
||
|
||
- In a system which contains more than two types of cameras, the setting items, adjustment range and adjustment accuracy available at the multi-camera operation are determined depending on the efficiency of the camera connected to the master unit.
|
||
|
||
- There are two setting modes: Absolute mode and relative mode.
|
||
|
||
- Settings performed on a slave unit are valid only to the connected camera.
|
||
|
||
|
||
# Setting a unit to the master unit or a slave unit
|
||
|
||
|
||
1
|
||
|
||
|
||
2
|
||
|
||
|
||
# Note
|
||
|
||
|
||
Perform the following procedure after making sure all
|
||
the cameras in the system are powered on. Note that
|
||
executing the procedure when there is any cameras
|
||
powered off may result in failure.
|
||
|
||
|
||
Select one RCP unit for the master unit, and press
|
||
the MASTER button. (The button lights when
|
||
pressed.)
|
||
|
||
|
||
Select one RCP unit (or more) for a slave unit, and
|
||
press the SLAVE button. (The button lights when
|
||
pressed.)
|
||
|
||
|
||
# Operating Multiple Cameras from One RCP Unit -Command Link
|
||
|
||
|
||
Command link allows one RCP selected as the master
|
||
unit to control the adjustments or settings of the
|
||
cameras connected to the slave units.
|
||
|
||
|
||
# To perform command link adjustments/ settings
|
||
|
||
|
||
The following table shows the adjustments or settings
|
||
which can be performed by command link. Perform a
|
||
listed operation before the desired adjustment or
|
||
setting on the master unit.
|
||
Other than the adjustment or setting listed in the table,
|
||
iris and master black can be adjusted by command link
|
||
in a different way.
|
||
|
||
|
||
For iris and master black adjustments, see "Adjusting the
|
||
Iris and Master Black of Multiple Cameras at One Time" on
|
||
next page.
|
||
|
||
|
||
26
|
||
|
||
|
||
|
||
|
||
|Adjustments/Settings|To perform command link operation|
|
||
|---|---|
|
||
|Gain settinga) (absolute mode)|Select the GAIN button on the COMM LINK ITEM-1 page in the OTHERS menu on the master unit.|
|
||
|Shutter setting (absolute mode) Shutter on/off Clear scan mode on/off Shutter speed Clear scan frequency|Select the SHUTTER button on the COMM LINK ITEM-1 page in the OTHERS menu on the master unit.|
|
||
|R/B manual white balance adjustment b) (relative mode)|Select the WHITE button on the COMM LINK ITEM-2 page in the OTHERS menu on the master unit.|
|
||
|R/B manual black balance adjustment b) (relative mode)|Select the BLACK button on the COMM LINK ITEM-2 page in the OTHERS menu on the master unit.|
|
||
|R/G/B manual flare correctionb) b), c) (relative mode)|Select the FLARE button on the COMM LINK ITEM-2 page in the OTHERS menu on the master unit.|
|
||
|
||
|
||
a)Do not perform command link operation in a system containing both the DXC-D30/D30P and DXC-637 series. If the
|
||
camera connected to a slave unit is different in type from the camera connected to the master unit, changing the gain value
|
||
on the master unit will set the gain value of the camera connected to the slave unit to 0 dB or the LOW position.
|
||
b)Select the manual adjustment mode also on slave units.
|
||
c)For DXC-D30/D30P only
|
||
|
||
|
||
# Adjusting the Iris and Master Black of Multiple Cameras at One Time
|
||
|
||
|
||
For iris and master black adjustments, you can use any
|
||
one of the RCP units (whether it is the master unit or a
|
||
slave unit) specified with the IRIS/M.BLACK LINK
|
||
button.
|
||
|
||
|
||
1 Select the cameras for which you will adjust the
|
||
iris or master black by pressing the IRIS/
|
||
|
||
|
||
M.BLACK LINK buttons on the connected RCP
|
||
|
||
|
||
units. (The buttons light when pressed.)
|
||
|
||
|
||
# 2 Adjust the iris or master black on one RCP unit whose IRIS/M.BLACK LINK button lights.
|
||
|
||
|
||
On the cameras connected to the RCP units whose
|
||
IRIS/M.BLACK LINK buttons light, the iris or
|
||
master black adjustments are performed by the
|
||
same amount and at the same time (on relative
|
||
mode).
|
||
|
||
|
||
# Data Transfer Among Multiple Cameras
|
||
|
||
|
||
The settings made on the master unit can be transferred
|
||
to the cameras connected to the slave units, if they can
|
||
be registered as a scene file (see page 21).
|
||
Perform as follows.
|
||
|
||
|
||
Press the COPY TO SLAVES button on the COPY TO
|
||
SLAVES page in the OTHERS menu on the master
|
||
unit.
|
||
|
||
|
||
Data transfer begins.
|
||
Meanwhile, on all the linked RCP units (including
|
||
units selected as neither the master unit nor slave
|
||
units), the message "COPY IN PROGRESS" is
|
||
displayed on the LCD panels and all buttons and knobs
|
||
are locked.
|
||
|
||
|
||
When the data transfer completes, the message "COPY
|
||
COMPLETED" appears on the LCD panels. The LCD
|
||
panel soon returns to the original status.
|
||
|
||
|
||
27
|
||
|
||
|
||
|
||
|
||
|Multi-Camera Specifications Control by Command Link|
|
||
|---|
|
||
||
|
||
|
||
|
||
Power supply 10 to 17 V (supplied from camera
|
||
or CCU)
|
||
Power consumption
|
||
|
||
|
||
4.0 W
|
||
|
||
|
||
Operating temperature
|
||
-10°C to +45°C (14°F to 113°F)
|
||
Storage temperature
|
||
-20°C to +55°C (-4°F to +131°F)
|
||
External dimensions
|
||
100 ´ 300 ´ 50 mm (4 ´ 11 7/8 ´
|
||
2 inches)
|
||
Weight 1.1 kg (2 lb 6 oz)
|
||
Maximum cable length
|
||
50 m (164 feet)
|
||
Data transfer method
|
||
New protocol complied with RS-
|
||
232C
|
||
Accessories Number plates (1 set)
|
||
Screws (+4 ´ 8, 2)
|
||
Washers (2)
|
||
Cable (1)
|
||
Operating instructions (1)
|
||
|
||
|
||
Design and specifications are subject to change
|
||
without notice.
|
||
|
||
|
||
Sony Corporation Printed in Japan
|
||
28
|
||
|
||
|
||
|
||
|
||
||ManualsLib Projects|
|
||
|---|---|
|
||
||www.manualslib.com|
|
||
||www.manualslib.de|
|
||
||www.manualslib.es|
|
||
||www.manualslib.fr|
|
||
||www.manualslib.nl|
|
||
||www.manualslib.mx|
|
||
||www.manualslib.tech 30+ Languages|
|
||
|
||
|