# Related Equipment and Cables
|
|
|
|
The RM-M7G and RCP-TX7 are best understood as part of a Sony SD camera remote
|
|
control ecosystem. Related camera control units and cables often contain the
|
|
pinout, mode, and compatibility details missing from the remote-panel manuals.
|
|
|
|
## CCA-7 Remote Cable
|
|
|
|
The CCA-7 family is the 10-pin remote cable used by the RM-M7G and RCP-TX7.
|
|
|
|
Known cable lengths:
|
|
|
|
- CCA-7-5.
|
|
- CCA-7-25.
|
|
- CCA-7-50.
|
|
- CCA-7-100.
|
|
|
|
Sony Japan CCA-7-25 page:
|
|
<https://www.sony.jp/pro/products/CCA-7-25/feature_1.html>
|
|
|
|
Important details from Sony Japan:
|
|
|
|
- Connects professional video cameras/camcorders and remote controls.
|
|
- 10-pin female to 10-pin male.
|
|
- Listed compatibility:
|
|
- DXC-D30/D35/327/537/637 series, CA-325 series, CCU-M5/M7 to RM-M7G.
|
|
- DXC-D30/D35/D50/D55 series to RCP-TX7/RCP-D50/RCP-D55.
|
|
|
|
The CCU-TX7 service manual includes a CCA-7 cable wiring diagram. Use that as
|
|
the better source for cable fabrication or continuity checks.
|
|
|
|
## CCU-TX7 / CCU-TX7P
|
|
|
|
Primary service manual:
|
|
<https://www.manualslib.com/manual/1068508/Sony-Ccu-Tx7.html>
|
|
|
|
The CCU-TX7 is directly relevant to RCP-TX7 because the RCP was designed for
|
|
CCU-TX7/TX7P camera systems with CA-TX7/TX7P camera adaptors.
|
|
|
|
Useful sections in the CCU-TX7 service manual:
|
|
|
|
- Connector input/output signals.
|
|
- REMOTE connector information.
|
|
- Connection connector list.
|
|
- CCA-7 cable wiring diagram.
|
|
- Board switch functions.
|
|
- Service information and disassembly.
|
|
- Video signal system adjustment.
|
|
- Triax interface system adjustment.
|
|
- Intercom/tally details.
|
|
|
|
The CCU-TX7 rear panel REMOTE connector is described as a 10-pin connector for
|
|
the RCP-TX7 via a CCA-7 cable.
|
|
|
|
## CCU-D50 / CCU-D50P
|
|
|
|
Official operation manual:
|
|
<https://pro.sony/s3/cms-static-content/operation-manual/3620534151.pdf>
|
|
|
|
Sony Japan product page:
|
|
<https://www.sony.jp/pro/products/CCU-D50/>
|
|
|
|
The CCU-D50 is useful because it bridges older RM-M7G-style operation and
|
|
RCP-TX7-style operation:
|
|
|
|
- `M5A mode` supports basic control using RM-M7G.
|
|
- `TX7 mode` supports more detailed camera operation using RCP-TX7.
|
|
|
|
The official CCU-D50 manual lists RCP-D50/D51, RCP-TX7, and RM-M7G as remote
|
|
control options. It also includes a section on using the RM-M7G remote control
|
|
unit and describes panel active handoff behavior.
|
|
|
|
The Japanese CCU-D50/CA-D50 catalog notes:
|
|
|
|
- CCU-D50 can use RM-M7G in M5A mode for basic DXC/DSR control.
|
|
- CCU-D50 can use RCP-TX7 in TX7 mode for broader picture-making controls.
|
|
- RCP-TX7 connector is circular 10-pin.
|
|
- RCP-TX7 power is DC 12 V, 10 V to 17 V range.
|
|
- RCP-TX7 power consumption is 4.0 W.
|
|
|
|
## DXC-D30 / DXC-D30WS
|
|
|
|
DXC-D30 user manual mirror:
|
|
<https://manualmachine.com/sony/dxcd30/551509-user-manual/>
|
|
|
|
This is useful for protocol research because it explicitly says the 10-pin
|
|
remote connector for RM-M7G and RCP-TX7 is designed according to RS-232C, and
|
|
that external PC control is possible with the proper Sony protocol.
|
|
|
|
System diagrams show:
|
|
|
|
- RM-M7G connected through CCA-7.
|
|
- RCP-TX7 connected through CCA-7.
|
|
- CCU-M7 / CCU-M5 camera control units.
|
|
- CCU-TX7 / CA-TX7 triax system.
|
|
|
|
## DXC-327B / DXC-327BP
|
|
|
|
Official Sony operating instructions PDF:
|
|
<https://pro.sony/s3/cms-static-content/operation-manual/3856085221.pdf>
|
|
|
|
Useful RM-M7G notes:
|
|
|
|
- RM-M7G connects with CCA-7-5/25/50/100 camera remote cable.
|
|
- CAMERA SELECT switch on RM-M7G should be set to `1`.
|
|
- Some RM-M7G controls do not affect camera output in this system.
|
|
- Some camera-side switches are disabled while RM-M7G is connected.
|
|
|
|
## DSR-390 / DSR-570WS Family
|
|
|
|
ManualMachine mirror:
|
|
<https://manualmachine.com/sony/powerhaddsr570wspl/1203049-user-manual/>
|
|
|
|
Useful notes:
|
|
|
|
- Has a 10-pin REMOTE connector for RM-M7G.
|
|
- CAMERA SELECT on RM-M7G should be set to `1`.
|
|
- EZ mode cannot be used while RM-M7G is connected.
|
|
- Power should be off before connecting or disconnecting remote equipment.
|
|
|