{ "name": "shutter-008f-evs-timeout-control", "notes": [ "Recover to CONNECT OK, force likely EVS via selector 0x008F, then deliberately do not clear it.", "This is the negative control for the adjacent-selector methodology: if the panel later blanks or falls to CONNECT NOT ACT, that is timeout cleanup, not proof that 0x008F clear worked.", "Record the time from EVS visibility to blank/CONNECT NOT ACT." ], "steps": [ { "action": "power_cycle", "off_seconds": 1.5 }, { "action": "wait_ready", "heartbeats": 2, "timeout": 10.0, "require": true }, { "action": "drain", "seconds": 0.25 }, { "action": "send", "label": "selector_zero_connect_ok_seed", "frame": "00 00 00 80 00 DA", "listen": 0.25 }, { "action": "send", "label": "e000_008f_likely_evs", "frame": "00 01 0F 08 00 5C", "listen": 4.0 } ] }