Manualslib.com - The Global Manuals Library Manuals / Brands / Sony Manuals / Control Unit / CCU-TX7 / Service manual / PDF # SONY CCU-TX7 SERVICE MANUAL # Quick Links Connector Input/Output Signals Connectors and Cables Wiring Diagram for Cable Connection Connector Connections # Table of Contents Table of Contents CONNECTORS AND CABLES Connector Input/Output Signals front panel Connection Connector Wiring Diagram for Cable MAKING OF WF MODE CONNECTOR COAX CONNECTOR OPERATING ENVIRONMENT MOUNTING ON 19-INCH RACK SWITCH FUNCTIONS ON BOARD BOARD LAYOUT DISASSEMBLY/INSTALLATION OF MAIN PART Removal of Cabinet Replacement of Switching Regulator Replacement of Fan board board EXTENSION OF DXBK-701 (SDI-44 BOARD) PREPARATION Equipment Required Fixture Notes on Adjustment Switch settings Connections VIDEO SIGNAL SYSTEM ADJUSTMENT Sub-carrier Frequency Check CAM H Phase Adjustment H Phase Adjustment SYNC Phase Adjustment INT SC Phase Adjustment Y CLAMP Adjustment Y OUT (COMP) Level Adjustment Y OUT (VBS) Level Adjustment G Level Adjustment R-Y/B-Y White Black Balance Adjustment R Level Adjustment B Level Adjustment WF OUT R/B DC OFFSET Adjustment Carrier Balance Adjustment Color Vector Adjustment # R-Y/B-Y OUT Level Adjustment VBS OUT Level Adjustment STAIR CASE Adjustment WIDE ID Level Adjustment # Y CABLE COMPENSATION SYSTEM ADJUSTMENT SYNC SEP Adjustment BLACK Pulse Width Adjustment SYNC Sample Hold Pulse Width Adjustment MHz VCO DC Set Adjustment Sample Pulse Width Adjustment Sample Pulse V Gate Width Adjustment MHz Carrier Level Adjustment Y DEMOD Carrier Balance Adjustment Y OFFSET Adjustment Y 90˚ Adjustment Y 1st AGC Adjustment Y Output Level Adjustment # CHROMA CABLE COMPENSATION SYSTEM ADJUSTMENT 45 MHz Carrier Level Adjustment C PLL Set Adjustment # B-Y DEMOD Carrier Balance Adjustment 1. -Y Crosstalk Adjustment C 1st AGC Adjustment # B-Y OUT Level Adjustment # R-Y DEMOD Carrier Balance Adjustment R-Y Crosstalk Adjustment # R-Y OUT Level Adjustment # RETURN VIDEO CABLE COMPENSATION SYSTEM ADJUSTMENT Return Video Deviation Adjustment # PROMPT VIDEO CABLE COMPENSATION SYSTEM ADJUSTMENT RX PROMPT VIDEO Demod. Adjustment RX PROMPT VIDEO RF AGC Adjustment RX PROMPT VIDEO Level Adjustment # TRIAX INTERFACE SYSTEM ADJUSTMENT Frequency Set Adjustment INCOM Deviation Adjustment PGM Deviation Adjustment INCOM Demodulation Adjustment INCOM Level Adjustment MIC 1 Demodulation Adjustment MIC 1 Level Adjustment MIC 2 Demodulation Adjustment MIC 2 Level Adjustment CAM DATA Demodulation Adjustment CAM TONE Adjustment # Other ManualsLib Projects # CAMERA CONTROL UNIT CCU-TX7 CCU-TX7P CAMERA OPERATION UNIT COU-TX7 SDI OUTPUT BOARD DXBK-701 SERVICE MANUAL Volume 1 1st Edition (Revised 2) Downloaded from www.Manualslib.com manuals search engine - ! WARNING This manual is intended for qualified service personnel only. To reduce the risk of electric shock, fire or injury, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so. Refer all servicing to qualified service personnel. ! WARNUNG Die Anleitung ist nur für qualifiziertes Fachpersonal bestimmt. Alle Wartungsarbeiten dürfen nur von qualifiziertem Fachpersonal ausgeführt werden. Um die Gefahr eines elektrischen Schlages, Feuergefahr und Verletzungen zu vermeiden, sind bei Wartungsarbeiten strikt die Angaben in der Anleitung zu befolgen. Andere als die angegeben Wartungsarbeiten dürfen nur von Personen ausgeführt werden, die eine spezielle Befähigung dazu besitzen. ! AVERTISSEMENT Ce manual est destiné uniquement aux personnes compétentes en charge de l'entretien. Afin de réduire les risques de décharge électrique, d'incendie ou de blessure n'effectuer que les réparations indiquées dans le mode d'emploi à moins d'être qualifié pour en effectuer d'autres. Pour toute réparation faire appel à une personne compétente uniquement. Downloaded from www.Manualslib.com manuals search engine CCU-TX7 (E)/V1 # Purpose of this manual ## MANUAL STRUCTURE This manual is the Service Manual Vol. 1 of the CAMERA CONTROL UNIT CCU-TX7 (for NTSC) and CCU-TX7P (for PAL), CAMERA OPERATION UNIT COU-TX7 and SDI OUTPUT BOARD DXBK-701. This manual contains the operation manual related to the operations of this equipment, the replacement of the parts and adjustments. ## Related manuals In addition to this Service Manual Vol. 1, the following manual is provided. . Service Manual Vol. 2 Part No. 9-977-286-23 Contains semiconductor pin and schematic diagrams. assignments, parts lists, block diagrams, board illustrations CCU-TX7 (E)/V1 Downloaded from www.Manualslib.com manuals search engine 1 Downloaded from www.Manualslib.com manuals search engine # TABLE OF CONTENTS 1. OPERATING INSTRUCTIONS 1-1. CCU-TX7/TX7P ............................................................................................ 1-1 1-2. DXBK-701 ................................................................................................... 1-13 2. INSTALLATION 2-1. CONNECTORS AND CABLES ................................................................... 2-1 2-1-1. Connector Input/Output Signals ............................................................. 2-1 2-1-2. Connection Connector ............................................................................ 2-4 2-1-3. Wiring Diagram for Cable ...................................................................... 2-4 2-2. MAKING OF WF MODE CONNECTOR .................................................... 2-4 2-3. COAX CONNECTOR ................................................................................... 2-5 2-4. OPERATING ENVIRONMENT ................................................................... 2-5 2-5. MOUNTING ON 19-INCH RACK ............................................................... 2-6 2-6. SWITCH FUNCTIONS ON BOARD ........................................................... 2-7 3. SERVICE INFORMATION 3-1. BOARD LAYOUT......................................................................................... 3-1 3-2. DISASSEMBLY/INSTALLATION OF MAIN PART ................................. 3-1 3-2-1. Removal of Cabinet ................................................................................ 3-1 3-2-2. Replacement of Switching Regulator ..................................................... 3-2 3-2-3. Replacement of Fan ................................................................................ 3-3 3-2-4. Removal of COU-TX7 ........................................................................... 3-3 3-3. CIRCUIT DESCRIPTION ............................................................................. 3-4 CT-181 board ....................................................................................................... 3-4 AA-90 board ........................................................................................................ 3-4 YD-26 board ........................................................................................................ 3-4 ES-20 board .......................................................................................................... 3-4 AU-234 board ...................................................................................................... 3-4 IO-140 board ........................................................................................................ 3-4 SDI-44 board (DXBK-701) ................................................................................. 3-4 3-4. EXTENSION OF DXBK-701 (SDI-44 BOARD) ......................................... 3-5 4. ADJUSTMENT CCU-TX7 (E)/V1 1. -1. PREPARATION ............................................................................................ 4-1 4-1-1. Equipment Required ............................................................................... 4-1 4-1-2. Fixture..................................................................................................... 4-1 4-1-3. Notes on Adjustment .............................................................................. 4-1 4-1-4. Switch settings ........................................................................................ 4-1 4-1-5. Connections ............................................................................................ 4-2 4-2. VIDEO SIGNAL SYSTEM ADJUSTMENT ................................................ 4-3 4-2-1. Sub-carrier Frequency Check ................................................................. 4-3 4-2-2. CAM H Phase Adjustment ..................................................................... 4-3 4-2-3. H Phase Adjustment ............................................................................... 4-4 Downloaded from www.Manualslib.com manuals search engine 3 1. -2-4. SYNC Phase Adjustment ....................................................................... 4-4 4-2-5. INT SC Phase Adjustment...................................................................... 4-5 1. -2-6. Y CLAMP Adjustment ........................................................................... 4-5 4-2-7. Y OUT (COMP) Level Adjustment ....................................................... 4-6 1. -2-8. Y OUT (VBS) Level Adjustment .......................................................... 4-6 4-2-9. R-Y/B-Y White Black Balance Adjustment........................................... 4-7 1. -2-10. G Level Adjustment ............................................................................... 4-7 4-2-11. R Level Adjustment................................................................................ 4-8 1. -2-12. B Level Adjustment................................................................................ 4-8 4-2-13. WF OUT R/B DC OFFSET Adjustment ................................................ 4-9 1. -2-14. Carrier Balance Adjustment ................................................................... 4-9 4-2-15. Color Vector Adjustment ..................................................................... 4-10 1. -2-16. R-Y/B-Y OUT Level Adjustment ........................................................ 4-10 4-2-17. VBS OUT Level Adjustment ............................................................... 4-11 1. -2-18. STAIR CASE Adjustment.................................................................... 4-11 4-2-19. WIDE ID Level Adjustment................................................................. 4-12 1. -3. Y CABLE COMPENSATION SYSTEM ADJUSTMENT......................... 4-13 4-3-1. SYNC SEP Adjustment ........................................................................ 4-13 4-3-2. BLACK Pulse Width Adjustment ........................................................ 4-13 4-3-3. SYNC Sample Hold Pulse Width Adjustment ..................................... 4-14 4-3-4. 22.5 MHz VCO DC Set Adjustment .................................................... 4-14 4-3-5. Sample Pulse Width Adjustment .......................................................... 4-15 4-3-6. Sample Pulse V Gate Width Adjustment ............................................. 4-15 4-3-7. 22.5 MHz Carrier Level Adjustment .................................................... 4-16 4-3-8. Y DEMOD Carrier Balance Adjustment.............................................. 4-16 4-3-9. Y OFFSET Adjustment ........................................................................ 4-17 4-3-10. Y 90˚ Adjustment ................................................................................. 4-17 4-3-11. Y 1st AGC Adjustment ........................................................................ 4-17 4-3-12. Y Output Level Adjustment ................................................................. 4-18 4-4. CHROMA CABLE COMPENSATION SYSTEM ADJUSTMENT .......... 4-18 4-4-1. 45 MHz Carrier Level Adjustment ....................................................... 4-18 4-4-2. C PLL Set Adjustment.......................................................................... 4-19 4-4-3. B-Y DEMOD Carrier Balance Adjustment.......................................... 4-19 4-4-4. B-Y Crosstalk Adjustment ................................................................... 4-20 4-4-5. C 1st AGC Adjustment......................................................................... 4-20 4-4-6. B-Y OUT Level Adjustment ................................................................ 4-21 4-4-7. R-Y DEMOD Carrier Balance Adjustment.......................................... 4-21 4-4-8. R-Y Crosstalk Adjustment ................................................................... 4-22 4-4-9. R-Y OUT Level Adjustment ................................................................ 4-22 1. -5. RETURN VIDEO CABLE COMPENSATION SYSTEM ADJUSTMENT............................................................................................ 4-23 4-5-1. Return Video Carrier Frequency Adjustment....................................... 4-23 4-5-2. Return Video Deviation Adjustment .................................................... 4-23 4-6. PROMPT VIDEO CABLE COMPENSATION SYSTEM ADJUSTMENT............................................................................................ 4-24 4-6-1. TX PROMPT VIDEO Demodulation Adjustment ............................... 4-24 4-6-2. RX PROMPT VIDEO Demod. Adjustment......................................... 4-25 4-6-3. RX PROMPT VIDEO RF AGC Adjustment ....................................... 4-26 4-6-4. RX PROMPT VIDEO Level Adjustment ............................................ 4-27 4 Downloaded from www.Manualslib.com manuals search engine CCU-TX7 (E)/V1 # 4-7. TRIAX INTERFACE SYSTEM ADJUSTMENT....................................... 4-27 1. -7-1. Frequency Set Adjustment ................................................................... 4-27 4-7-2. INCOM Deviation Adjustment ............................................................ 4-28 1. -7-3. PGM Deviation Adjustment ................................................................. 4-28 4-7-4. INCOM Demodulation Adjustment ..................................................... 4-29 1. -7-5. INCOM Level Adjustment ................................................................... 4-29 4-7-6. MIC 1 Demodulation Adjustment ........................................................ 4-30 1. -7-7. MIC 1 Level Adjustment ...................................................................... 4-30 4-7-8. MIC 2 Demodulation Adjustment ........................................................ 4-31 1. -7-9. MIC 2 Level Adjustment ...................................................................... 4-31 4-7-10. CAM DATA Demodulation Adjustment ............................................. 4-32 4-7-11. CAM TONE Adjustment...................................................................... 4-32 CCU-TX7 (E)/V1 Downloaded from www.Manualslib.com manuals search engine 5 Downloaded from www.Manualslib.com manuals search engine 1. -859-845-12(1) # Camera Control Unit Operating Instructions Before operating the unit, please read this manual thoroughly and retain it for future reference. ## CCU-TX7/TX7P  1997 by Sony Corporation Downloaded from www.Manualslib.com manuals search engine # WARNING To prevent fire or shock hazard, do not expose the unit to rain or moisture. For the customers in the USA This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment. This device requires shielded interface cables to comply with FCC emission limits. This symbol is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. This symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. ## Owner's Record The model and serial numbers are located at the rear. Record the serial number in the space provided below. Refer to these numbers whenever you call upon your Sony dealer regarding this product. Model No. Serial No. 2 ## Table of Contents Overview ............................................................................ 4 Product Features .................................................................. 4 Connections ......................................................................... 5 Installing the Camera Operation Unit ................................. 7 Location and Function of Parts ....................................... 8 Front Panel .......................................................................... 8 Rear Panel ......................................................................... 14 Internal Board Switches and Knobs .................................. 17 Notes on Use ................................................................... 20 Specifications .................................................................. 21 3 Downloaded from www.Manualslib.com manuals search engine # Over Overviewview ## Pr oduct Features ||of how to connect other devices to this unit Some of the video camera's switches and buttons| |---|---| |connects to DXC-637 Series and DXC-D30 Series|are shown in the following. may not operate while the CCU-TX7/TX7P is| ||| ||Notes| The CCU-TX7/TX7P is a camera control unit that Color Video Cameras via the CA-TX7/TX7P Camera Adaptor. This product's features are described below. ## Full-featured signal transfer functions  The CCU-TX7/TX7P is able to transfer wideband component video signals. (Y signals at 9 MHz or above, and R-Y and B-Y signals at 4.5 MHz or above) When using a triaxial cable, audio signals can be transferred up to 750 meters (2461 feet) (when cable diameter is 8.5 mm (11/32 inch)) or 1,500 meters (4921 feet) (when cable diameter is 14.5 mm (19/32 inch)).  Transfer functions are provided for the following signals. Return video, teleprompter signal, microphone audio, program audio, red tally and green tally signals An intercom switch is also provided. Y/R-Y/B-Y,1) RETURN R/G/B,Y/C MIC VIDEO OUT ## Flexibly adaptable camera control functions INTERCOM/ TALLY VBS  The optional COU-TX7 Camera Operation Unit, which can be installed on the CCU-TX7/TX7P's front panel, enables video camera operations to be controlled from the CCU-TX7/TX7P. INTERCOM (front panel) Reference sync signal When several CCU-TX7/TX7P units are connected in parallel, the optional RCP-TX7 Remote Control Panel can be used to control video camera operations as well as the color balance between cameras. An RS-232C connector is provided for the CCU- TX7/TX7P, allowing a personal computer to be connected for computer-based control of video camera operations. GENLOCK CAMERA Triaxial cable PROMPT VIDEO Teleprompter signal CCA-7 cable DC IN REMOTE DC power source 2) CCU-TX7/TX7P 3) PIX WF SYNC AC IN ## Wide array of input/output signals The input and output connectors provided for the CCU-TX7/TX7P include those for outputting such signals as a composite video signal (VBS), component video signals (switchable to RGB), SDI signals, and video signals for video and waveform monitors, for inputting a reference signal for external synchronization. ## Rack mountable Two CCU-TX7/TX7P units can be installed side by side in the optional RMM-TXC7 Rack Mount Bracket. 4 ## Connections Control console Headset Headset CA-TX7/TX7P DXC-D30/D30P CCU/CAMERA AC power source 2) AC power cord (supplied) VIDEO IN VIDEO IN REF IN RCP-TX7 Video monitor Waveform monitor 5 Be sure to power the CCU-TX7/TX7P off before inserting or removing the triaxial cable connector. ## When using one CCU-TX7/TX7P unit For details, see the operation instructions for the video camera or camera adaptor. Out In In In In/Out 1) Y/R-Y/B-Y, R/G/B, and Y/C outputs are switchable. 2) Use either AC or DC power source. 3) This illustration shows the CCU-TX7. ## Downloaded from www.Manualslib.com manuals search engine # Over view Switcher with SDI input 6 ## When using two CCU-TX7/TX7P units ## DXC-D30/D30P VCR ## 1 Open the CCU-TX7/TX7P's front panel. Y/R-Y/B-Y,R/G/B,Y/C 1) Chroma keyer VBS GENLOCK Reference sync signal RETURN VIDEO Return video signal CA-TX7/TX7P Triaxial cable CAMERA Teleprompter signal PROMPT VIDEO CCA-7 cable PROMPT VIDEO (For power sources, see the connections illustrated for the unit shown below.) REMOTE RETURN VIDEO CCU/CAMERA RS232C CCU-TX7/TX7P 3) ## 2 Remove the blank panel and the connector cap. GENLOCK Stopper Switcher, video monitor, etc. Connector cap ## DXC-D30/D30P Blank panel RCP-TX7 Y/R-Y/B-Y,R/G/B,Y/C1) VCR VBS Chroma keyer GEN LOCK CA-TX7/TX7P CAMERA Triaxial cable RETURN VIDEO PROMPT CCA-7 cable VIDEO REMOTE DC IN CCU/CAMERA DC power CCU-TX7/ SDI AC IN source 2) TX7P 3) OUT4) AC power cord RS232C (supplied) AC power source 2) 3 Attach the camera operation unit to the front panel and connect the flat cable to the connector. Flat cable Camera operation unit ## 4 Close the front panel and fasten the screws. Monitor with SDI input RCP-TX7 Personal computer (When the RCP-TX7s are not connected.) VCR with SDI input Waveform monitor with SDI input 1. Y/R-Y/B-Y, R/G/B, and Y/C outputs are switchable. 2. Use either AC or DC power source. 3. This illustration shows the CCU-TX7. Switcher, video monitor, etc. 1. Using the SDI OUT connectors requires the optional DXBK-701 board. ## Installing the Camera Operation Unit The following describes how to fit the optional COU- TX7 Camera Operation Unit to the CCU-TX7/TX7P's front panel. 7 ## Downloaded from www.Manualslib.com manuals search engine # Location Location and and Function of P Function of Parts ## arts Various switches, adjustment knobs, and connectors are located on the front panel, rear panel, and also on the edges of internal boards. ## Front P anel From the front panel, you can operate the CCU-TX7/ TX7P's switches and knobs as well as the camera operation unit's switches and knobs (when the optional COU-TX7 Camera Operation Unit has been installed). For description of how to install the camera operation unit, see "Installing the Camera Operation Unit" (page 7). CCU-TX7/TX7P switches and knobs (see page 9) Camera operation unit switches and knobs (see page 10) 6 POWER switch and indicator TALLY CABLE ALARM OPERATE SHORT OPEN LOCK PART FULL SHUTTER CALL OUTPUT GAIN CAM HIGH MID BARS LOW SKIN DETAIL Hz ON OFF WHITE/BLACK BALANCE WHITE AUTO ATW PRE BLACK MANUAL ## TLCS 1 TALLY lamp The lamp lights red when a red tally signal is received and green when a green tally signal is received. It also lights red when the CALL button is pressed on the CA-TX7/TX7P Camera Adaptor or RCP-TX7 Remote Control Panel connected to this unit. The camera number plate (provided) can be attached to this lamp. INTERCOM connector (XLR 5-pin): Use this to connect a headset. INTERCOM (intercom level) knob: Use this to adjust the intercom sound volume. PGM (program audio level) knob: Use this to adjust the sound volume when monitoring program audio via a headset. MIC switch: Use this switch to turn the headset's microphone ON or OFF. LINE switch: Use this switch to select the channel for intercom signals that are input and output via the INTERCOM connector.  CH1: Connects to channel 1  CH2: Connects to channel 2  PRIV: Does not connect to channel 1 or channel 2. Instead, the intercom operates only between this unit and the connected video camera. ## M.GAMMA C.SCAN ON OFF CAMERA INTERCOM POWER MIC LINE ON CH1 AUTO PRIV ON OFF CH2 MANUAL INTERCOM PGM OFF BLACK KNEE MASTER BLACK AUTO PUSH POWER PRESET ## DETAIL ## WHITE ## IRIS ## AUTO ## MANUAL 8 ## CCU-TX7/TX7P switches and knobs 1 TALLY lamp 4 INTERCOM audio input/output and setting section ## TALLY CABLE ALARM SHORT OPEN 2 CABLE ALARM indicator ## CALL 3 CALL button CAMERA INTERCOM POWER MIC LINE ON CH1 ## PRIV ON ## OFF CH2 INTERCOM PGM ## OFF PUSH ## POWER MIC switch LINE switch PGM knob INTERCOM knob PUSH INTERCOM connector 4 INTERCOM audio input/ output and setting section 5 CAMERA POWER switch and indicator 2 CABLE ALARM indicator SHORT: this indicator lights when an overcurrent occurs in the triaxial cable connected to the CAMERA connector on the rear panel. OPEN: this indicator lights when there is no triaxial cable connected to the CAMERA connector on the rear panel or when the current flowing in the connected triaxial cable is excessively small. 3 CALL button When you press this button, it lights along with the red TALLY lamps and CALL buttons on the video camera, camera adaptor, and remote control panel connected to this unit. This function can be used to call the video camera or remote control panel operator. You can then talk with the operator via the intercom. This button also lights when the CALL button is pressed on the camera adaptor or remote control panel. INTERCOM MIC LINE ON CH1 PRIV OFF CH2 INTERCOM PGM 5 CAMERA POWER switch and indicator When the POWER switch is on, use this switch to switch the power on and off to the video camera and camera adaptor connected to this unit. The indicator lights when this switch is turned on powering the camera adaptor. 6 POWER switch and indicator This switches the power to this unit on or off. The indicator lights when the power is on. 9 ## Downloaded from www.Manualslib.com manuals search engine # Location and Function of Parts ## Camera operation unit switches and knobs 1 OUTPUT switch ## SHUTTER 7 GAIN switch WHITE AUTO/PRE/MANUAL switch Hz ## C.SCAN ON OFF OPERATE OUTPUT GAIN TLCS LOCK HIGH CAM PART MID FULL BARS LOW SHUTTER SKIN M.GAMMA DETAIL Hz ATW button WHITE/BLACK BALANCE AUTO WHITE AUTO ATW PRE MANUAL BLACK MANUAL 2 OPERATE switch 8 TLCS switch $ button and 4 button 3 SHUTTER setting section 9 M. GAMMA knob C.SCAN ON ON OFF OFF DETAIL WHITE/BLACK BALANCE AUTO WHITE AUTO ATW PRE MANUAL BLACK MANUAL SHUTTER switch ## BLACK 0 SKIN DETAIL switch !¡ DETAIL knob ## WHITE WHITE knob WHITE knob (blue) (red) BLACK knob (red) SHUTTER switch: Use this switch to select a shutter setting. This switch does not function when the TLCS switch is on. 4 WHITE/BLACK BALANCE control section BLACK knob (blue) ON WHITE 1234 ## BLACK ## KNEE MASTER BLACK AUTO -  C. SCAN: This activates the clear scan function. ## IRIS ## AUTO !£ DIP switch -  ON: This activates the normal shutter function.  OFF: This turns off the shutter. 5 KNEE switch ## BLACK AUTO/MANUAL switch ## PRESET MANUAL 6 MASTER BLACK knob !™ IRIS control section The camera operation unit's switches and knobs are used to set and adjust video camera functions. For details about the video camera functions and settings, refer to operating instructions for your video camera. 1 OUTPUT switch Use this switch to select the video to be output from this unit. CAM: Image being shot via video camera BARS: Color bars generated by this unit 2 OPERATE (operation range setting) switch Use this switch to set the operation range of the camera operation unit. LOCK: This setting disables all of the camera operation unit's functions. PART: This setting enables only the IRIS control section and MASTER BLACK knob to be operated. FULL: This setting enables all of the camera operation unit's functions to be used. Settings changed while this switch was set to LOCK become valid when this switch is set to FULL. 10 3 SHUTTER setting section Display - $ button and 4 button: When the SHUTTER switch is set to either C. SCAN or ON, pressing one of these buttons changes the shutter speed or clear scan frequency as described below.  When SHUTTER switch is set to C. SCAN Pressing and holding one of these buttons gradually reduces ($ button) or increases (4 button) the clear scan frequency.  When SHUTTER switch is set to ON Each time one of these buttons is pressed, the shutter speed is reduced ($ button) or increased (4 button) by one step. If you press both of these buttons at once, it resets the clear scan frequency or shutter speed (depending on the SHUTTER switch's position) to their factory settings. Display: This displays the clear scan frequency when the SHUTTER switch is set to C. SCAN or the shutter speed when it is set to ON. "OFF" is displayed here when the SHUTTER switch is set to the OFF position. When the TLCS switch is on, the display is blank. 4 WHITE/BLACK BALANCE control section BLACK AUTO/ MANUAL switch WHITE/BLACK switch and indicators Use this switch to select whether to automatically (AUTO) or manually (MANUAL) adjust the black balance. (When a DXC-637 series video camera is connected, this switch is invalid and the black balance mode is determined by the position of the WHITE AUTO/PRE/ MANUAL switch.) WHITE/BLACK (white/black balance adjustment) switch and indicators When the WHITE AUTO/PRE/MANUAL switch is set to AUTO, press this switch to the WHITE position to automatically adjust the white balance. When the BLACK AUTO/MANUAL switch is set to AUTO, press this switch to the BLACK position to automatically adjust the black balance. The indicator by the WHITE or BLACK position blinks at a one-second interval while the white balance or black balance is being automatically adjusted. When the automatic adjustment is completed, it stays lit for about ten seconds, then goes out. If the automatic adjustment fails, it blinks at a half-second interval for about ten seconds and then goes out. 11 ## Downloaded from www.Manualslib.com manuals search engine # Location and Function of Parts ## WHITE AUTO/PRE/MANUAL (white balance auto/preset/manual) switch Use this switch to select the white balance adjustment mode. This switch does not function while the ATW function is being used (while the ATW button is lit). AUTO: This sets auto adjustment mode. It enables the white balance to be automatically adjusted using the WHITE/BLACK switch. (When a DXC-637 series video camera is connected: this also sets auto adjustment mode for the black balance. The black balance can be automatically adjusted even while the ATW function is being used.) PRE: This sets preset mode. The white balance is maintained at the preset value. (When a DXC-637 series video camera is connected: this also sets auto adjustment mode for the black balance. The black balance can be automatically adjusted even while the ATW function is being used.) MANUAL: Sets manual adjustment mode. It enables the white balance to be manually adjusted using the WHITE knob (red) and WHITE knob (blue). (When a DXC-637 series video camera is connected: this also sets manual adjustment mode for the black balance. The black balance can be adjusted manually even while the ATW function is being used.) ATW (auto tracing white balance) button Press this button (which lights up when pressed) to have the white balance adjusted automatically when lighting conditions change. BLACK (black balance) knob (red) When the BLACK AUTO/MANUAL switch is set to MANUAL, this knob can be used to adjust the black level of the R signal. BLACK (black balance) knob (blue) When the BLACK AUTO/MANUAL switch is set to MANUAL, this knob can be used to adjust the black level of the B signal. WHITE (white balance) knob (red) When the WHITE AUTO/PRE/MANUAL switch is set to MANUAL, this knob can be used to adjust the gain of the R signal. WHITE (white balance) knob (blue) When the WHITE AUTO/PRE/MANUAL switch is set to MANUAL, this knob can be used to adjust the gain of the B signal. 5 KNEE switch Use this switch to adjust the knee setting. AUTO: Knee is automatically adjusted PRESET: Knee is adjusted to preset value ## MASTER BLACK knob 6 This adjusts the master black (master pedestal level) setting. The click position of the knob provides a typical setting. 7 GAIN switch Use this switch to set any of three video amp gain levels (HIGH, MID, or LOW). The gain value corresponding to these levels can be set using a menu on the video camera. 8 TLCS (total level control system) switch Press this switch to turn the total level control system on or off. The switch lights when it is turned on. When this switch is on, settings made with the GAIN switch and SHUTTER switch are ignored. (This function cannot be used when a DXC-637 series video camera is connected.) 9 M. GAMMA (master gamma) knob Use this knob to adjust the gamma curve. The click position of the knob provides a typical setting. (This function cannot be used when a DXC-637 series video camera is connected.) 0 SKIN DETAIL switch Use this switch to turn the skin detail correction function on or off. (This function cannot be used when a DXC-637 video camera is connected.) series !¡ DETAIL knob Use this knob to adjust the detail level. The click position of the know proides a typical setting. 12 !™ IRIS control section IRIS AUTO/MANUAL switch ## IRIS ## AUTO ## MANUAL Iris adjustment knob ## IRIS AUTO/MANUAL switch Use this switch to select between AUTO and MANUAL iris adjustment modes. Be sure that the IRIS switch on the video camera is set to AUTO. AUTO: Iris is automatically adjusted. MANUAL: Iris is adjusted with the iris adjustment knob. Iris adjustment knob When the IRIS AUTO/MANUAL switch is set to MANUAL, this knob can be used to manually adjust the iris. When the IRIS AUTO/MANUAL switch is set to AUTO, this knob can be used to manually fine-tune the automatic iris adjustment. !£ DIP switch Use the four switches numbered 1 to 4 to make the following settings. No.1 OFF/No.2 OFF Standard color matrix setting No.1 OFF/No.2 ON (This setting has no effect when a DXC-D30 series video camera is connected.) No.1 ON/No.2 OFF Color matrix set for fluorescent lighting (FL). (This setting has no effect when a DXC-D30 series video camera is connected.) No.1 ON/No.2 ON Color matrix set for color emphasis (H.SAT). (This setting has no effect when a DXC-D30 series video camera is connected.) No.3 ON EVS function set on for the shutter. (Has priority over the SHUTTER switch setting on the camera operation unit.) No.4 ON Date and time display set on for the output picture. 13 ## Downloaded from www.Manualslib.com manuals search engine # Location and Function of Parts ## Rear Panel 9 OUTPUT connectors ## PGM IN ## OUTPUT VBS1 1 2 R/R-Y/C !º Fan ## CAMERA 1 PGM IN connector ## VBS2 1 2 G/Y/Y |2 CAMERA connector 3 RTS connector 4 COAX connector 5 REMOTE connector 6 WF MODE connector 7 INTERCOM/TALLY connector 8 RS232C connectors|COAX REMOTE WF MODE CH1|2 OFF 75Ω RETURN VIDEO ON SPARE OFF 75Ω 2 ON OFF 75Ω PROMPT VIDEO DC IN PIX 1 B/B-Y WF SYNC RTS 1 2 CH2 BREAKER MIC OUT CH2 CH1 SDI OUT AC IN RS232C|!¡ INPUT connectors and 75 Ω termination switches !™ MIC OUT connectors !£ DC IN connector !¢ SDI OUT connectors !∞AC IN connector !§ Breaker switch Illustration: CCU-TX7||9 OUTPUT connectors R/R-Y/C, G/Y/Y, and B/B-Y VBS1 and VBS2 connectors PIX connector WF connector|type) OUTPUT VBS1 1 2 R/R-Y/C VBS2 1 2 G/Y/Y PIX 1 2 B/B-Y WF SYNC SPARE SPARE connector|0 A If the of !¡|fan is fan should supplier Sony when the equipment. section and|in. the CAMERA POWER switch off the power, and consult for repair. Continuing to use is defective may shorten the life (BNC type) and 75-Ω four pairs of loop-through 75-Ω termination| |---|---|---|---|---|---|---|---|---|---| INPUT GENLOCK ON OFF 75Ω 1 ON 1 PGM IN (program audio input) connector (XLR 3-pin) The program audio signal is input via this connector. 2 CAMERA connector (triaxial) Connect a triaxial cable here to connect this unit to the CA-TX7/TX7P Camera Adaptor attached to a video camera. 3 RTS (intercom) connector (XLR 3-pin) Use this connector to connect an RTS intercom system or a Clear-Com intercom system. Contact a Sony dealer before using this connector. 4 COAX (coaxial) connector (BNC type) Use this connector for input and output of signals from the video camera connected via a coaxial cable. No power is supplied to the video camera or camera adaptor via the coaxial cable. Internal board settings must be changed before using this connector. For details, contact a Sony dealer. 5 REMOTE (remote control panel) connector (10- pin) Use this connector to connect the RCP-TX7 Remote Control Panel via a CCA-7 cable. 6 WF MODE (waveform monitor mode) connector (4-pin) Connect to the corresponding connector on a waveform monitor when monitoring signals in sequential mode. Internal board settings must be changed before using this connector. For details, contact a Sony dealer. 7 INTERCOM/TALLY connector (D-sub 25-pin) Intercom signals and tally signals are input and output via this connector. Connect to the intercom system's INTERCOM/TALLY connector. 14 8 RS232C connectors (D-sub 25-pin) There are two connectors, CH1 and CH2. You can use these connectors to connect a personal computer to control the video camera. You may also use these connectors to connect this unit to another CCU-TX7/TX7P unit. It is possible to carry out color balancing or linked iris adjustment between two or more interconnected CCU-TX7/TX7P units using the RCP-TX7 Remote Control Panel. For details, refer to the operating instructions for the RCP- TX7. SYNC connector 1 ## RETURN VIDEO 2 ## PROMPT VIDEO ## R/R-Y/C, G/Y/Y, and B/B-Y (component video signal/RGB signal/Y and C signal output) connectors Use these connectors to output the signals from the video camera as component signals (R-Y, B-Y, and Y), RGB signals for chroma keying, or Y and C signals. Use a switch on an internal board (ES-20) to select the type of output signal. VBS1 and VBS2 (composite video signal 1 and 2 output) connectors Use these connectors to output signals from a video camera as composite video signals. SYNC (sync signal output) connector This connector outputs a SYNC signal (0.3 Vp-p, 75 Ω). Connect to the synchronization signal input connector on a waveform monitor or video monitor. PIX (picture monitor output) connector Use this connector to output a video signal to a video monitor. Use the MONITOR SELECT button on the RCP-TX7 Remote Control Panel to set the type of signal to be output. Selection of the signal type also applies to the output from the WF connector. WF (waveform monitor output) connector Use this connector to output a video signal to a waveform monitor. Use the MONITOR SELECT button on the RCP-TX7 Remote Control Panel to set the type of signal to be output. Selection of the signal type also applies to the output from the PIX connector. SPARE connector This connector is not used (it is reserved for future use). Note the fail, indicator flashes. Immediately your dealer unit fan the INPUT connectors termination switches This includes connectors corresponding switches. INPUT GENLOCK ON GENLOCK connectors OFF 75Ω ON OFF 75Ω ON OFF 75Ω ON OFF 75Ω RETURN VIDEO 1 and RETURN VIDEO 2 connectors PROMPT VIDEO connectors ## 75-Ω termination switches GENLOCK (generator lock) connectors Use these connectors to input a reference sync signal (black burst signal or composite video signal) for external synchronization . ## RETURN VIDEO 1 and RETURN VIDEO 2 connectors These connectors correspond to the RETURN 1 and RETURN 2 buttons on the CA-TX7/TX7P Camera Adaptor. Two sets of return video signals can be input via these two pairs of connectors. 15 ## Downloaded from www.Manualslib.com manuals search engine # Location and Function of Parts ## PROMPT VIDEO connectors Use these connectors to input teleprompter signals. ## 75-Ω termination switches When only one loop-through connector is used and the other connector in the pair is not connected to any external device, set the corresponding 75-Ω termination switch to the ON position. !™ MIC OUT connectors (XLR 3-pin) Use these connectors to output microphone signals (CH1 and CH2) from the connected video camera. !£ DC IN connector (XLR 4-pin) Use this connector to operate this unit using a DC power source (10.5 to 17 V). CT-181 AA-90 YD-26 ES-20 ## SDI-44 1 ES-20 board 2 AA-90 board 3 CT-181 board SDI-44 board (DXBK-701) a) !¢ SDI (serial digital interface) OUT connectors 1 and 2 (BNC type) These output the signals from the video camera as SDI signals. Connect them to a digital VCR, digital video switcher, video monitor, or other device with an SDI input connector. Using the SDI OUT connectors requires the optional DXBK-701 board. For details, refer to the operating instructions for the DXBK-701. !∞ AC IN connector Use this connector to connect an AC power source via the supplied power cord. Use the supplied plug retainer to attach the power cord to this unit. !§ Breaker switch If the input current exceeds 10 A during operation of the unit on a DC power source, the breaker is actuated to shut off the power supply. To resume operation, push in the breaker switch after making sure the input current does not exceed 10 A. 16 ## Internal Board Switches and Knobs Loosen the two screws on the right side of the front panel to expose switches and knobs on the edges of internal boards. For details concerning adjustment of internal board switches and knobs, contact a Sony dealer. Front panel screws a) The SDI-44 board is an option available as the DXBK-701. For details of installation and operation, refer to the operating instructions supplied with the DXBK-701. YD-26 board 17 ## Downloaded from www.Manualslib.com manuals search engine # Location and Function of Parts 1 ES-20 board 2 AA-90 board ## MIC TEST switch ## OUTPUT 1 and OUTPUT 2 switches PANEL (panel control) switch When the COU-TX7 Camera Operation Unit has been installed on this unit while the RCP-TX7 Remote Control Panel is also connected to the unit, use this switch to select the camera operation unit or the remote control panel as the control device. REMOTE: Enables the video camera to be controlled from the remote control panel. LOCAL: Disables remote control (via the remote control panel) of the video camera. ## ES-20 PHASE H AA-90 PGM IN 0dB H PHASE adjustment screw PGM IN switch -20dB SC 3 CT-181 board MIC 1 LEVEL 0dB SC PHASE switch and fine-tuning screw -20dB 0 MIC 1 LEVEL and MIC 2 LEVEL switches MIC 2 LEVEL 0dB 180 -20dB OUTPUT 1 R/G/B Y/R-Y/B-Y Y/C OUTPUT 2 R/G/B Y/R-Y/B-Y Y/C MIC TEST CH1 CH2 OFF LEVEL IND ## CONTROL MODE switch MIC TEST switch CT-181 R TALLY CONTACT POWER DC24V TTL G TALLY CONTACT POWER DC24V TTL OUTPUT 1 and OUTPUT 2 switches If another CCU-TX7/TX7P unit is connected to this unit, use this switch to select whether the video camera is controlled directly from this unit or from the other CCU-TX7/TX7P unit. NORMAL: Video camera is controlled directly from this unit. SLAVE: Video camera is controlled from other CCU-TX7/TX7P unit. This switch does not operate when the RCP-TX7 Remote Control Panel is connected to this unit. In this case, use the remote control panel to make the above selection. LEVEL IND indicators R TALLY and G TALLY switches INTERCOM 2W CLEAR RTS COM 4W RTS CLEAR COM INTERCOM switches MIC GAIN NORM CH1 MIN MAX NORM CH2 MIN MAX PANEL REMOTE LOCAL CONTROL MODE NORMAL SLAVE MIC GAIN adjustment screws ## H PHASE (horizontal phase) adjustment screw ## PGM IN (program audio input level setting) switch Use this switch to set the program audio input level to 0 dB or -20 dB. PANEL switch Turn this screw with a screwdriver to adjust the horizontal phase alignment between an external sync signal and the output signal. CONTROL MODE switch ## SC PHASE (subcarrier phase setting) switch and fine-tuning screw Use this switch and screw to adjust the output signal subcarrier phase with respect to an external sync signal. After setting the SC PHASE switch, turn the fine-tuning screw to make fine adjustments. Use these switches to select the type of signal to be output via the OUTPUT connectors (R/R-Y/C, G/Y/Y, B/B-Y). The OUTPUT 1 switch corresponds to the three OUTPUT connectors on the left side and the OUTPUT 2 switch to the three OUTPUT connectors on the right side. R/G/B: Selects output of R, G, and B signals from the OUTPUT connectors. Y/R-Y/B-Y: Selects output of R-Y, Y, and B-Y component signals from the OUTPUT connectors. Y/C: Selects output of Y and C signals from the OUTPUT connectors. 18 ## MIC 1 LEVEL and MIC 2 LEVEL switches Use these switches to set the microphone output levels for channel 1 (CH1) and channel 2 (CH2) to 0 dB or -20 dB. Set this switch to CH1 or CH2 to mix that channel's microphone signals from the video camera with the program audio, so that the mixed input can be monitored via a headset connected to this unit or a camera adaptor. This switch is used to check the microphone signals. ## LEVEL IND (microphone level) indicators The transfer levels for microphone signals (CH1 and CH2) are indicated by colors. The upper indicator corresponds to channel 1 (CH1) and the lower one to channel 2 (CH2). Green: Approximately -12 dB to 0 dB Orange: Approximately 0 dB to +12 dB Red: Approximately +12 dB or higher Use these indicators along with the MIC TEST switch to check microphone signal lines or as a adjustment indicator when adjusting the microphone gain with a MIC GAIN adjustment screw on the CT-181 board. INTERCOM (intercom system select) switches Use these switches to select the type of external intercom system to be used. Set the upper switch to 4W if no external intercom is connected. If you set the upper switch to RTS, select either RTS or CLEARCOM with the lower switch. ## R TALLY (red tally) and G TALLY (green tally) switches Set these switches to CONTACT (to use contact signals) or POWER (to use voltage signals) for the red tally and green tally. If you set them to POWER, select either DC24V or TTL. ## MIC GAIN adjustment screws Use these screws to adjust the microphone amplifier gain for the camera adaptor. The standard level (NORM) is 0 dB, and the gain setting can be adjusted to any of 16 levels from -12 dB (MIX) to +12 dB. Adjust the gain so that, on the AA-90 board, the green and orange LEVEL IND indicators are lit while the audio level is normal with the red indicator lighting only when the maximum audio level is reached. If the red indicator does not light at all, or if the orange indicator lights only intermittently, raise the gain level. If the red indicator stays lit, lower the gain. 19 ## Downloaded from www.Manualslib.com manuals search engine # Location Notes and on Use Function of Parts ## Use and storage locations Avoid using or storing the unit in the following places: Where it is subject to extremes of temperature (operating temperature: 5°C to 40°C (41°F to 104°F)). Note that in summer the temperature in a car with the windows closed can reach 50°C (122°F).  Very damp or dusty places. Where rain is likely to reach the unit. -  Places subject to severe vibration. -  Near strong magnetic fields -  Near transmitting stations generating strong radio waves. ## Avoid violent impacts Dropping the unit, or otherwise imparting a violent shock to it, is likely to cause it to malfunction. ## Do not cover with cloth While the unit is in operation, do not cover it with a cloth or other material. This can cause the temperature to rise, leading to a malfunction. ## After use Turn the unit off. ## Care If the body of the unit is dirty, wipe it with a dry cloth. For severe dirt, use a soft cloth steeped in a small amount of neutral detergent, then wipe dry. Do not use volatile solvents such as alcohol or thinners, as these may damage the finish. 20 ## Specifications ## General Power requirements CCU-TX7: 120 VAC, 50/60 Hz CCU-TX7P: 220 to 240 VAC, 50/ 60 Hz, 0.45 A 10.5 to 17.0 VDC Power consumption 95 W Cable length 1500 m max. (diameter: 14.5 mm ) Operating temperature 5°C to 40°C (41°F to 104°F) Mass About 8.45 kg (18 lb 10 oz) Dimensions (w/h/d, excluding protruding parts) 200 × 164 × 370 mm (7 7/8 × 6 1/2 × 14 5/8 inches) ## Input connectors GENLOCK BNC type (2, loop-through) VBS/BS, 1.0Vp-p, 75 Ω RETURN VIDEO 1, 2 BNC type (2 each, loop-through) VBS, 1.0 Vp-p, 75 Ω PROMPT VIDEO BNC type (2, loop-through) VBS, 1.0 Vp-p, 75 Ω PGM IN XLR 3-pin (1) MIC OUT Y/C 1) SDI 2) SYNC XLR 3-pin (2) 0 dBu/-20 dBu balanced, 2 channels BNC type (2 each) 1. : 1.0 Vp-p, 75 Ω C: 286 mV (CCU-TX7)/300 mV (CCU-TX7P) (burst), 75 Ω BNC type (2) SDI format, 270 Mbps, SMPTE 259M (CCU-TX7)/CCIR656-III (CCU-TX7P) BNC type (1) 0.3 Vp-p, 75 Ω, negative polarity ## Camera control input/output connectors CAMERA Triaxial (1) COAX BNC type (1) REMOTE 10-pin (1) INTERCOM/TALLY D-sub 25-pin (1) 4W/2W TALLY: 24 VDC, TTL level or contact signals switchable RTS XLR 3-pin (2) RS232C D-sub 25-pin (2) INTERCOM(on the front panel) XLR 5-pin (1) ## Output connectors VBS1, VBS2 Y/R-Y/B-Y1) ## Accessories supplied BNC type (1 each) VBS, 1.0 Vp-p, 75 Ω BNC type (2 each) Y: 1.0 Vp-p, 75 Ω R-Y/B-Y: 700 mVp-p (CCU- TX7)/525 mVp-p (CCU-TX7P), 75 Ω BNC type (2 each) 700 mVp-p, 75 Ω BNC type (1), 1.0 Vp-p, 75 Ω BNC type (1) 700 mVp-p, 75 Ω Encoded output: 1.0 Vp-p, 75 Ω 4-pin (1) AC power cord (1) Power cord plug retainer (1) Number plates (1 set) Operation Manual (1) ## Optional accessories R/G/B1) COU-TX7 Camera Operation Unit DXBK-701 SDI Output Board RCP-TX7 Remote Control Panel RMM-TXC7 Rack Mount Bracket PIX WF WF MODE Design and specifications are subject to change without notice. .......................................................................................................................................................................................................... 1. Y/R-Y/B-Y, R/G/B, and Y/C outputs are switchable. 2. When the optional DXBK-701 is installed. 21 ## Downloaded from www.Manualslib.com manuals search engine English # To switch the DXC-D30WS/D30WSP aspect ratio To switch the DXC-D30WS/D30WSP Digital Video Camera connected to this unit via the CA-TX7/TX7P Camera Adaptor between 16:9 and 4:3 aspect ratios, use the following methods. ## When using the RCP-TX7 Remote Control ## Panel Switch the aspect ratio using advanced setting page 9/11 of the RCP-TX7's OTHERS menu. ## When using the COU-TX7 Camera Operation ## Unit Switch the aspect ratio using the DXC-D30WS/ D30WSP's advanced menu. ## Wide-aspect ID signals When using the DXC-D30WS/D30WSP connected to this unit via the CA-TX7/TX7P with the 16:9 aspect ratio, wide-aspect ID signals1) are added to the video signals2) output from this unit. It is possible to change the internal board settings of this unit so that the ID signals are not added to the video signals. For more information about this, consult your Sony service representative. 1. Complying with EIAJ CPR-1204 (CCU-TX7) or ETS WSS (CCU-TX7P). 2.  Composite video signals 1 and 2 (output from the VBS1 and VBS2 connectors)  Video signal for video monitors (output from the PIX connector)  Video signal for waveform monitors (output from the WF connector)  Component video Y signal (output from the Y connector)  Y signal of Y and C signal output (output from the Y connector) ## CCU-TX7/TX7P English ## Pin assignment of the INTERCOM/TALLY connector The pin assignment for the unit's INTERCOM/ TALLY connector (D-sub 25-pin) is as follows. 13 12 11 10 9 8 7 6 5 4 3 2 1 25 24 23 22 21 20 19 18 17 16 15 14 |No. Signal name 1 GREEN TALLY (Y) IN 14 GREEN TALLY (X) IN|Specifications ON: 24V DC/TTL(H)/Short OFF: 0V DC/TTL(L)/Open| |---|---| |2 RED TALLY (Y) IN 15 RED TALLY (X) IN|ON: 24V DC/TTL(H)/Short OFF: 0V DC/TTL(L)/Open| |3 GND|Ground for intercom remote signal| |16 CAM MIC OFF IN 4 CH2 INT IN|L: Camera intercom off L: Channel-2 interrupt on| |17 CH1 INT IN 5 4W CH2 (R) (G) OUT 18 4W CH2 (R) (Y) OUT 6 4W CH2 (R) (X) OUT|L: Channel-1 interrupt on 4-wire channel-2 system receive, 0 dBu balanced| |19 4W CH2 (T) (G) IN 7 4W CH2 (T) (Y) IN 20 4W CH2 (T) (X) IN|4-wire channel-2 system talk, 0 dBu balanced| |8 2W CH2 (G) IN/OUT 21 2W CH2 (X) IN/OUT 9 4W CH1 (R) (G) OUT 22 4W CH1 (R) (Y) OUT 10 4W CH1 (R) (X) OUT|2-wire channel-2 system, 0 dBu Recommended termination impedance: 600 ohms 4-wire channel-1 system receive, 0 dBu balanced| |23 4W CH1 (T) (G) IN 11 4W CH1 (T) (Y) IN 24 4W CH1 (T) (X) IN|4-wire channel-1 system talk, 0 dBu balanced| |12 2W CH1 (G) IN/OUT 25 2W CH1 (X) IN/OUT|2-wire channel-1 system, 0 dBu Recommended termination impedance: 600 ohms| |13 CHASSIS GND|Chassis ground| 0 dBu=0.775 Vrms 3-864-243-01(1) ## Downloaded from www.Manualslib.com manuals search engine 1. -866-203-01(1) # SDI Output Board Operating Instructions Page 11 GB # DXBK-701  1998 by Sony Corporation Downloaded from www.Manualslib.com manuals search engine # Downloaded from www.Manualslib.com manuals search engine ## English ## For the customers in the USA This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment. The shielded interface cable recommended in this manual must be used with this equipment in order to comply with the limits for a digital device pursuant to Subpart B of Part 15 of FCC Rules. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. ## For the customers in Canada This Class A digital apparatus complies with Canadian ICES-003. 11 For the customers in Europe This product with the CE marking complies with the EMC Directive (89/336/EEC) issued by the Commission of the European Community. Compliance with this directive implies conformity to the following European standards: EN55103-1: Electromagnetic Interference (Emission) EN55103-2: Electromagnetic Susceptibility (Immunity) This product is intended for use in the following Electromagnetic Environment (s): E1 (residential), E2 (commercial and light industrial), E3 (urban outdoors) and E4 (controlled EMC environment ex. TV studio) |Auto Level Adjustment .................................................17|||| |---|---|---|---| Overview ......................................................................... 12 Location and Function of Parts.................................... 13 Fitting and Adjustment ................................................. 14 Specifications ................................................................ 18 Overview The DXBK-701 SDI Output Board is an option board for the Sony CCU-TX7/TX7P Camera Control Unit. When this board is fitted in a CCU-TX7/TX7P, it provides an SDI digital signal output. Note This board can be fitted to a CCU-TX7 with serial number 11001 or greater or a CCU-TX7P with serial number 41001 or greater. 1) When this board is fitted, the heat generated can cause burns. .......................................................................................................................... Be sure to have the board fitted by your Sony dealer. 1) Fitting the board to a CCU-TX7 with serial number 11000 or below or a CCU-TX7P with serial number 41000 or below requires a separate modification to the CCU-TX7/TX7P. Consult your Sony dealer about 12 this. || |---| || SDI-44 ALARM 1 ALARM indicator 2 SDI output connectors 3 AUTO LEVEL indicator 1 ALARM indicator This lights red when the SDI signal is not being output. 2 SDI output connectors Connect the two cables from the CCU. 3 AUTO LEVEL indicator This lights green when the automatic video level adjustment is carried out correctly. 4 AUTO LEVEL switch With the output set to color bars, press this switch to carry out automatic video level adjustment. 5 SDI POWER switch Set this to ON to use the SDI output. When not using the SDI output, set to OFF to conserve power. 13 Downloaded from www.Manualslib.com manuals search engine # Fitting and Adjustment Power off the CCU-TX7/TX7P before fitting the board. 1 Check that the switches on the DXBK-701 board (SDI-44) are set as follows. FREE LOCK: LOCK ADJ OPE: OPE AUDIO MODE: normally 2CH; 4CH if the connected device does not support 2CH mode. (No audio output is provided on channels 3 and 4.) FREE LOCK FREE LOCK ADJ OPE ADJ OPE 4ch 2ch AUDIO MODE Board retainer 14 SDI output connectors 2 Loosen the two screws at the right end of the front panel of the CCU-TX7/TX7P, and open the front panel. Remove the board retainer (two screws). Clamp Cables (Continued) ## Downloaded from www.Manualslib.com manuals search engine 3 Insert the board partly into the slot. 4 Remove the two cables temporarily fixed to the CCU-TX7/ TX7P power supply unit from the clamp, and connect to the two SDI output connectors on the board. It does not matter which cable is connected to which connector. 15 # Fitting and Adjustment ## 5 Push the board fully in, and refasten the board retainer, using the two screws removed in step 2. Board retainer ### 6 Set the SDI POWER switch to ON. (See page 13.) 7 Power on the CCU-TX7/TX7P, and carry out auto level adjustment. (See page 17.) ### 8 Close the front panel of the CCU-TX7/TX7P, and fasten the screws. 16 ### Auto Level Adjustment 1 Power on the CCU-TX7/TX7P, CA-TX7/TX7P, and camera. 2 On the RCP-TX7 or COU-TX7/TX7P select "BARS". Color bars appear in the monitor or viewfinder. 3 With a pen or other sharp implement, press the AUTO LEVEL switch. The auto level adjustment is necessary to ensure that the video levels are appropriate. Carry out auto level adjustment in step 6 (page 16) of the procedure under "Fitting and Adjustment". After a few seconds, when the AUTO LEVEL indicator lights in green the auto level adjustment is completed. ### Notes  If the indicator lights in red, check the switch setting on the board. (See step 1 on page 14.) If the indicator flashes, check that color bars are being displayed.  The adjustment values are stored on this board, so readjustment is not normally required. However, if the CCU-TX7/TX7P is not used for a long time (several months), or if the board is installed in a different CCU-TX7/TX7P, the auto level adjustment must be made again. For details of the operating procedures for other devices, refer to the operating instructions supplied with each device. 17 ### Downloaded from www.Manualslib.com manuals search engine || |---| || # Specifications Power consumption Operating temperature Mass Dimensions Output signal 4.5 W 5°C to 40°C (41°F to 104°F) 330 g (11 oz) 17 × 148 × 277 mm (11/16 × 5 7/8 × 11 inches) (w/h/d, excluding projections) SDI output connectors SDI format (270 Mbps) SMPTE 259M (CCU-TX7)/ CCIR 656-III (CCU-TX7P) 18 ## Downloaded from www.Manualslib.com manuals search engine # SECTION 2 INSTALLATION ## 2-1. CONNECTORS AND CABLES ## 2-1-1. Connector Input/Output Signals The connector input/output signals are described below. ## 1. Rear panel BNC connector: 75 Z ## [Input signals] - . GENLOCK (BNC) - . RETURN VIDEO 1/2 (BNC) : - . PROMPT VIDEO (BNC) : - . SPARE (BNC) *1 : VBS/BS, 1.0 V p-p VBS, 1.0 V p-p VBS, 1.0 V p-p :RM Video Input VBS, 1.0 V p-p ## [Output signals] - . R (BNC) *2 : 700 mV p-p . G (BNC) *2 : 700 mV p-p . B (BNC) *2 : 700 mV p-p . Y (BNC) *2 : 1.0 V p-p . R-Y (BNC) *2 : 700 mV p-p : 525 mV p-p . B-Y (BNC) *2 : 700 mV p-p : 525 mV p-p . C (BNC) *2 : 286 mV p-p (for CCU-TX7) : 300 mV p-p . PIX (BNC) : 1.0 V p-p - . VBS 1/2 (BNC) : 140 IRE - . SYNC (BNC) : VBS, 0.3 V p-p, - . WF (BNC) : 700 mV p-p (Encoded output : 1.0 V p-p) - . SDI OUT (BNC) : 800 mV p-p (for CCU-TX7) (for CCU-TX7P) (for CCU-TX7) (for CCU-TX7P) (burst) (for CCU-TX7P) negative - *1:Located on the OUTPUT connector block of the rear panel for the unit with the following Serial Nos. Serial No. 13016 and higher (UC) Serial No. 42930 and higher (CE) - *2:R/G/B, Y/R-Y/B-Y, Y/C selection (Selectable with S800, S801 on the ES-20 board) ## [Input/Output signals] - . TRIAX : King type (for CCU-TX7) Fischer type (for CCU-TX7P) - . COAX (BNC) - . MIC OUTPUT CH1/CH2 (XLR 3P, MALE) ## (EXTERNAL VIEW) |No.|Signal|Specifications| |---|---|---| |1|MIC OUT (G)|0 dBu/ _20 dBu| |2|MIC OUT (Y)|(Selectable with MIC switch on AA-90| |3|MIC OUT (X)|board)| (0 dBu = 0.775 Vrms) . WF MODE (4P, FEMALE) 4 1 3 2 ## (EXTERNAL VIEW) ## No. Signal 1 SEQ CONT OUT (G) 2 SEQ CONT OUT (X) 3 STAIR CASE OUT (X) 4 STAIR CASE OUT (G) ∗1) Stair Case signal (0 dBu = 0.775 Vrms) Specifications OPEN COLLECTOR ∗1) GND for STAIR CASE 10 ±2 V R GB DC0 ±2 V CCU-TX7 (E)/V1 2-1 Downloaded from www.Manualslib.com manuals search engine # . INTERCOM/TALLY (D-Sub 25P, FEMALE) 13 1 1 13 25 14 25 14 ## (EXTERNAL VIEW) ## (EXTERNAL VIEW) ## (0 dBu = 0.775 Vrms) ## (0 dBu = 0.775 Vrms) ## No. Signal ## Specifications ## No. Signal ## Specifications 1 CHASSHIS GND 2 TXDATA 3 RXDATA This is based on RS-232C specification. 38,400 bps or 9600 bps Switchable by the internal switch on the CT-181 board of CCU. ON : 24 V DC/TTL (H)/SHORT OFF : 0 V DC/TTL (L)/OPEN ON : 24 V DC/TTL (H)/SHORT OFF : 0 V DC/TTL (L)/OPEN GND for INTERCOM REMOTE 1 GREEN TALLY (Y) IN 14 GREEN TALLY (X) IN 2 RED TALLY (Y) IN 15 RED TALLY (X) IN 3 GND 16 CAM MIC OFF IN 4 CH2 INT IN 17 CH1 INT IN 5 4W CH2 (R) (G) OUT 18 4W CH2 (R) (Y) OUT 6 4W CH2 (R) (X) OUT 19 4W CH2 (T) (G) IN 7 4W CH2 (T) (Y) IN 20 4W CH2 (T) (X) IN |8|2W CH2 (G) IN/OUT|2W CH2 SYSTEM 0 dBu| |---|---|---| |21|2W CH2 (X) IN/OUT|Recommended Term. imp.= 600 Z| |9|4W CH1 (R) (G) OUT|4W CH1 SYSTEM RECEIVE| |22|4W CH1 (R) (Y) OUT|0 dBu BALANCED| |10|4W CH1 (R) (X) OUT|| |23|4W CH1 (T) (G) IN|4W CH1 SYSTEM TALK| |11|4W CH1 (T) (Y) IN|0 dBu BALANCED| |24|4W CH1 (T) (X) IN|| |12|2W CH1 (G) IN/OUT|2W CH1 SYSTEM 0 dBu| |25|2W CH1 (X) IN/OUT|Recommended Term. imp.= 600 Z| |13|CHASIS GND|| 4 RTS 5 CTS 6 DSR 7 GND 20 DTR 1. : CAM INCOM MIC OFF L: CH2 INTERRUPT ON L: CH1 INTERRUPT ON 4W CH2 SYSTEM RECEIVE 0 dBu BALANCED 4W CH2 SYSTEM TALK 0 dBu BALANCED 2-2 Downloaded from www.Manualslib.com manuals search engine ## . RS-232C CH1/CH2 (D-Sub 25P, FEMALE) ## . REMOTE (10P FEMALE) 8 1 7 2 10 9 6 3 5 4 ## (EXTERNAL VIEW) ## Specification - VBS, 1.0 V p-p ## No. Signal 1 (SPARE) 2 RM VIDEO OUT (X) * 3 RM VIDEO OUT (G) * 4 S. DATA (RCP → CCU) 5 S. DATA GND RX DATA equivalent communication rate that is based on RS-232C specification is 38,400 bps. TX DATA equivalent communication rate that is based on RS-232C specification is 38,400 bps. output the RM video out signal. |8|(SPARE)|-| |---|---|---| |9|POWER +12.5 V DC GND|GND for +12.5 Vdc| |10|POWER +12.5 V DC OUT|10.6 V to 17.0 Vdc| 6 S. DATA GND 7 S. DATA (CCU → RCP) *:The units with the following Serial Nos. Serial No. 13016 and higher (UC) Serial No. 42930 and higher (CE) CCU-TX7 (E)/V1 # . PGM IN (XLR 3P, FEMALE) ## 2. Front panel ## . INTERCOM (XLR 5P, FEMALE) ## (EXTERNAL VIEW) |No.|Signal|Specifications| |---|---|---| |1|PGM IN (G)|0 dBu/ _20 dBu| |2|PGM IN (X)|(Selectable with PGM switch on AA-90| |3|PGM IN (Y)|board)| ## . RTS IN/OUT (XLR 3P, FEMALE ↔ MALE) FEMALE MALE Loop-through (EXTERNAL VIEW) (EXTERNAL VIEW) |No.|Signal||Specifications| |---|---|---|---| |1|GND||0 dBu/ _10 dBu (Clear-Com)| |2|RTS CH2 (X)||Current drive| |3|RTS CH1 (X)||Recomended Term. lmp.= 200 Z| . DC IN (XLR 4P, MALE) ## (EXTERNAL VIEW) No. Signal 1 INCOM (T) (G) IN 2 INCOM (T) (X) IN 3 NCOM (R) (G) OUT 4 INCOM (R) (X) OUT 5 PGM (X) OUT ## (0 dBu = 0.775 Vrms) ## Specifications _60 dBu (DYNAMIC MIC) _20 dBu (CARBON MIC) GND for HEADPHONE _0 dBu (Max. 18 dBu) |No.|Signal|Specifications| |---|---|---| |1|GND|GND for DC (+)| |2|(SPARE)|-| |3|(SPARE)|-| |4|DC (+) IN|DC 10.5 V to 17 V| ## (EXTERNAL VIEW) CCU-TX7 (E)/V1 2-3 Downloaded from www.Manualslib.com manuals search engine # 2-1-2. Connection Connector Use the connectors below or the equivalent at its tip when cables are connected to each connector on the connector panel during installation and servicing. ## Connector name ## Connected connector/cable GENLOCK VIDEO 1, 2 RETURN VIDEO PROMPT VIDEO R/R-Y/C 1, 2 G/Y/Y 1 B/B-Y 1, 2 WF PIX VBS 1/2 SYNC COAX (BNC type) |INTERCOM/TALLY|D-Sub, 25-pin male,| |---|---| |RS-232C CH1/CH2|JAE DA-25PF-N or the| |(25P, FEMALE)|| |WF MODE|1-560-343-11 male| |(4P, FEMALE)|| |REMOTE|1-766-848-11 male, or| |(10P, FEMALE)|CCA cable| ||CCA-7-5 with RCP-TX7)| ||(50 m max.)| |INTERCOM|1-508-370-11 XLR, male,| |(5P, FEMALE)|or CANNON XLR-5-12-C or the| ||equivalent| 1-560-069-11 plug, BNC, or B-B cable assembly (1.5 m in cable length, optional) MIC CH1/CH2 RTS (3P, MALE) 1. -508-083-00 XLR, 3-pin FEMALE or CANNON XLR-3-11C or the equivalent 1-508-084-00 XLR, 3-pin MALE or CANNON XLR-3-12C or the equivalent PGM IN RTS ## 2-1-3. Wiring Diagram for Cable . CCA-7 cable Blue White Orange Black Green 8 1 7 2 910 8 1 7 2 910 6 6 3 5 4 3 5 4 White Brown White Red Yellow ## 2-2. MAKING OF WF MODE CONNECTOR . When connecting plug to wave form monitor, make the plug as follow. PLUG (4P) (Sony part No. 1-560-343-11) To wave form monitor (REMOTE) 4 1 3 2 (EXTERNAL VIEW) GROUND 4 1 3 2 (WIRING SIDE) STAIR CASE SEQ CONT 2-4 Downloaded from www.Manualslib.com manuals search engine CCU-TX7 (E)/V1 # 2-3. COAX CONNECTOR The COAX connector (BNC type) can be used for connection between the CCU and the CA with a BNC cable instead of a triaxial cable. In this case, supply the power source from outside to the CA side. And for the CA side, it is needed to modify the TRIAX harness to the COAX harness. For the CCU, the following modification is required. Disconnect the RF cable from the CN3 on the IO-141 board and reconnect it to the CN4. RF cable IO-140 board |||||light.|||| |---|---|---|---|---|---|---|---| ||||||||| ||CN4||||||| ## 2-4. OPERATING ENVIRONMENT Operating temperature : +5 dC to +40 dC Storage temperature : _20 dC to +55 dC Humidity : Noncondcnsing Supply voltage : 100 V to 240 V ±10% Power consumption : 95 W (maximum) (50/60 Hz) 1. Do not put the unit in a place subject to high temperature or in a location near hear sources. 2. Do not put the unit in a place subject to excessive electrical and magnetic fields. 3. Put the unit in a dry and well-ventilated place. 4. Do not put the unit in a place subject to excessive dust and mechanical shock. 5. Do not put the unit in a place subject to direct sunlight and 8 200 9.5 217.5 (Unit: mm) CCU-TX7 (E)/V1 2-5 Downloaded from www.Manualslib.com manuals search engine # 2-5. MOUNTING ON 19-INCH RACK Two CCU-550s can be mounted on a 19-inch EIA standard rack in parallel by using rack mount adaptor RMM-TXC7 (optional). ## Mounting 1. Tighten the four rack mount screws. RMM-TXC7 B5 screws (60 mm or more long) 2. Mount the CCU-TX7/TX7P on the rack mount adaptor as shown in the figure below and tighten the four fixing screws (supplied for RMM-TXC7). ||| |---|---| ||Screws Screws| 2-6 Downloaded from www.Manualslib.com manuals search engine CCU-TX7 (E)/V1 # 2-6. SWITCH FUNCTIONS ON BOARD ## CT-181 board LV3 E13 S2002 TP22 PROMPT CN7 S1001 PANEL SELECT S1004 RX TX RS232C-2 CN8 PROMPT RF RX IF BOARD PANEL REMOTE TP1001 LOCAL TP2001 E16 TP2003 TP2002 TP2004 CONTROL MODE NORMAL SLAVE TP2005 CT-181 Board (A SIDE) E1001 TP2006 RET FREQ CV1 CT-181 R TALLY R TALLY CONTACT S2011 CONTACT POWER TP1000 POWER E12 DC24V RF AGC DLY RV22 S2013 DC24V TTL G TALLY CONTACT POWER E1000 TTL R TALLY CONTACT G TALLY POWER DC24V G TALLY TTL MIC 1 GAIN SW1000 SW1001 MIC 2 GAIN PROMPT FREQ S2012 RV23 PROMPT LEVEL PROMPT TUNE DC24V TTL S2014 MIC GAIN NORM CH-1 MIN MAX NORM CH-2 MIN MAX NORM CONT MODE SLAVE S1002 - . S1000 This switch is for the adjustment in the factory. Factory setting : All OFF - . S2002 (PROMPT SELECT TX/RX) TX :When selecting the TX mode, the CCU modulates the VBS signal input to the PROMPT VIDEO IN connector on the CCU-TX7/TX7P, and modulated signal is sent to the CA-TX7/TX7P. RX : When selecting the RX mode, the CA modulates the VBS signal input to the PROMPT VIDEO IN connector on the CA-TX7/TX7P, and modulated signal is sent to the CCU-TX7/TX7P. Note : When using this switch, change as follows. . In case of using the TX mode (TX side) ; 1) Disconnect CN8 and connect CN3 and CN7 on the CT-181 board. 2) Set S1 and S6 switches to "PROMPTER" side on the YD-25 board of CA-TX7/TX7P. . In case of using the RX mode (RX side) ; 1) Disconnect CN7 and connect CN3 and CN8 on the CT-181 board. 2) Set S1 and S6 switches to "AUX" side on the YD-25 board of CA-TX7/TX7P. Factory setting : TX - . S1001 (PANEL REMOTE/LOCAL) When the RCP or COU is connected, the connected one is selected in spite of PANEL setting. Also, when both RCP and COU are connected, RCP or COU is selected according to the PANEL (REMOTE/ LOCAL) setting. Factory setting : REMOTE Note : RCP : Remote Control Panel RCP-TX7 COU : Camera Operation Unit COU-TX7 - . S1002 (CONTROL MODE NORMAL/SLAVE) The RCP is only connected or both RCP and COU are connected and then the S1001 switch is set to REMOTE side. In this case, the RCP is valid, and this S1002 switch is invalid. The COU is only connected or both RCP and COU one connected, and then the S1001 switch is set to LOCAL side. In this case, the COU is valid, and this S1002 switch is used as follows ; NORMAL : COU can be used SLAVE : The operation of CCU can be used. COU can not be used. Factory setting : NORMAL - . S1004 This switch is used to change the RS-232C and IF BOARD. Factory setting : RS-232C side - . S2011 (R TALLY POWER/CONTACT) - . S2013 (R TALLY DC24 V/TTL) These switches are set according to the signal standard of the R TALLY signal input to the INTERCOM/TALLY/ PGM connnector on the CCU rear panel. For the relation between the signal and switch setting, refer to the table below. Factory setting : (S2011) POWER (S2013) DC 24 V - . S2012 (G TALLY POWER/CONTACT) - . S2014 (G TALLY DC 24 V/TTL) These switches are set according to the signal standard of the G TALLY signal input to the INTERCOM/TALLY/ PGM connector on the CCU rear panel. For the relation between the signal and switch setting, refer to the table below. Factory setting : (S2012) POWER (S2014) DC 24 V |Switch||Signal|method| |---|---|---|---| |||Power|V) TTL (+5 V)| |S2011, S2012||Power|Power| |S2013, S2014|DC 24 V or|DC24 V|TTL| - . SW1000 (MIC GAIN ... CH1) - . SW1001 (MIC GAIN ... CH2) Use these screws to adjust the microphone amplifier gain for the camera adaptor. The standard level (NORM) is 0 dB, and the gain setting can be adjusted to any of 16 levels from _12 dB (MIX) to +12 dB. CCU-TX7 (E)/V1 2-7 Downloaded from www.Manualslib.com manuals search engine # AA-90 board T201 T301 E12 ## AA-90 TP9 TP12 TP44 PGM IN 0dB -20dB MIC 1 LEVEL 0dB -20dB MIC 2 LEVEL 0dB -20dB MIC TEST CH-1 CH-2 OFF LEVEL IND T401 E10 TP15 TP43 TONE TUNE LV101 5.6M TUNE TP7 LV21 LV61 LV41 4.3M 3.6M 1. CCU DATA E11 E1 TP46 LV1 3.0M H CONT INTER COM 2W (CLEAR ) RTS COM 4W RTS CLEAR COM TP3005 TP3002 E3001 TP3004 RV2000 SIDE TONE TP3003 AA-90 Board (A SIDE) ## Intercom select switches (S2002, S2003, S2005, S2007) - . S2002 (INCOM SELECT 2W/RTS/4W) Select according to the intercom system. Factory setting : 4W - . S2003 (INCOM MODE 1CH/2CH) Set to 1CH or 2CH according to the intercom system. The interface circuit of CH1 side only works with the switch set to 1CH position. Factory setting : 2CH - . S2005 (RTS/Clear-Com) This switch selects RTS or Clear-Com position when the S2002 switch is set to RTS position. Factory setting : RTS - . S2007 (RTS CH REV STD/REV) Applicable Serial No. 10801 and Higher [UC] Applicable Serial No. 40136 and Higher [CE] This switch allows RTS input/output to be switched between CH1 Factory setting : STD (PROD*1) and CH2 (ENG*2) when it sets to REV. - *1 : Corresponds to PROD side of the intercom selector switch for CCU-550, CCU-550P and so on. - *2 : Corresponds to ENG side of the intercom selector switch for CCU-550, CCU-550P and so on. Set the S2002, S2003, S2005 and S2007 switches to the positions shown in the table below, according to the intercom system. X : Don't care |Intercom system to be|S2002|S2003 S2005 S2007|Remarks| |---|---|---|---| |4-wire system|4W|2CH X X|| |2-wire system|2W|2CH X X|| |RTS TW (2CH)|RTS|2CH RTS REV|CH1 (CCU) 5 CH1 (RTS)| ||||CH2 (CCU) 5 CH2 (RTS)| |||STD|CH1 (CCU) 5 CH2 (RTS)| ||||CH2 (CCU) 5 CH1 (RTS)| |Clear-Com 1 ch system|1CH|Clear-Com STD|| |Clear-Com TW system|2CH|Clear-Com REV|| 2-8 Downloaded from www.Manualslib.com manuals search engine CCU-TX7 (E)/V1 - . S201 (MIC 1 LEVEL) This switch sets the audio signal level of the MIC OUTPUT CH-1 connector on the CCU rear panel to 0 dBu or _20 dBu. Factory setting : 0 dBu - . S301 (MIC 2 LEVEL) This switch sets the audio signal level of the MIC OUTPUT CH-2 connector on the CCU rear panel to 0 dBu or _20 dBu. Factory setting : 0 dBu - . S2004 (MIC TEST) This switch is for mixing the MIC (1 or 2) audio from the CA-TX7/TX7P with the program audio (PGM) and for monitoring the audio. CH-1 : MIC 1 audio mixes to the program audio. CH-2 : MIC 2 audio mixes to the program audio. OFF : MIC 1 audio and MIC 2 audio do not mix to the program audio. Factory setting : OFF - . S2006 (RTS 200 Z ON/OFF) This switch sets to ON or OFF position for 200 Z termination in the RTS system. Usually, this switch sets to OFF position because the RTS system has 200 Z termination. Factory setting : OFF - . S2081 (PGM IN) This switch sets the PGM (program audio) level to 0 dBu or _20 dBu. Factory setting : 0 dBu CCU-TX7 (E)/V1 2-9 Downloaded from www.Manualslib.com manuals search engine # YD-26 board TP26 TP10 E5 YD-26 Board (A SIDE) SAMPL GATE RV3 E1 RV1 Y AGC CONT SAMPL S/H E2 RV4 TP11 Y LEVEL RV9 E6 RV17 R-Y LEVEL TP2 TP5 TP8 TP4 TP7 Y RF TUNE TP6 RV2 RV5 LV1 BLACK S/H SYNC S/H TP3 S4 C 2'nd AGC E7 B-Y CARR BAL TP13 TP14 RV11 Y OFFSET ADJ RV8 ## YD-26 RV6 VCO DC SET Y 2'nd AGC S3 TP9 TP12 TP17 RV12 1. -Y LEVEL E8 E9 ## R-Y CARR BAL RV16 TP19 1. TP15 RV10 C AGC CONT RV18 90° SET RV13 RV14 RV15 OFFSET ADJ PLL SET C CAR LEV E16 TP1 E4 S2 CABLE LENGTH S1 E3 TP21 TP20 - . S1 (MODE AUTO/MANU) The length of a triax cable connecting the camera head and CCU is automatically detected and set when this switch is set to AUTO. The triax cable length can be manually set using S2 (CABLE LENGTH SELECT) when this switch is set to MANU (MANUAL). Factory setting : AUTO |Switch|Cable length (center value)| |---|---| |0|100 m| |1|300 m| |2|500 m| |3|700 m| |4|NOT IN USED| - . S3 (Y-ch 2nd AGC ON/OFF) - . S4 (CHROMA-ch 2nd AGC ON/OFF) These switches are used for RF AGC adjustment. Usually, set these switches to ON. - . S2 (CABLE LENGTH SELECT) This switch is valid when S1 is set to MANU. This switch is set to the number corresponding to the cable length. Factory setting : 0 (100 m) 2-10 Downloaded from www.Manualslib.com manuals search engine CCU-TX7 (E)/V1 # ES-20 board Y LEVEL (VBS) SYNC LEVEL (VBS) RV804 CHROMA LEVEL RV810 SYNC WIDTH RV3 RV2 SYNC PHASE RV803 RV802 E3 ## ES-20 Y LEVEL(COMP) ## PHASE RV801 SYNC LEVEL(COMP) RV800 Y SETUP LEVEL (NTSC ONLY) RV7 H PHASE H SC RV6 SC PHASE RV4 TP1 SC FREQUENCY 0 180° RV812 B-Y LEVEL RV5 SC-H PHASE OUT PUT 1 R/G/B Y/R-Y/B-Y Y/C OUT PUT 2 R/G/B Y/R-Y/B-Y Y/C E1 G MAT BAL2 B WHT BAL R WHT BAL RV506 RV505 RV500 S1 TP501 RV508 RV507 G MAT BAL1 G LEVEL TP502 R MAT BAL RV509 RV510 R LEVEL TP503 B MAT BAL RV512 RV513 B LEVEL TP7 TP5 TP4 TP2 TP3 ## R-Y BLK BAL RV501 POSITION RV511 R DC BAL ## R-Y GAIN ADJ RV502 RV1000 LEVEL RV514 B DC BAL RV504 RV503 B-Y GAIN ADJ B-Y BLK BAL ES-20 Board (A SIDE) - . S1 (V BLKG 19H/20H/21H) ... NTSC only This switch sets the V blanking width to 19H, 20H, or 21H. Set this switch according to the application. Factory setting : 20H - . S2 (H BLKG) This switch is used for H blanking width adjustment. During factory setting, this switch is set so that the H blanking with is 10.9 ±0.2 usec. Set this switch according to the application. - . S3 (SC 0d/180d) This switch is used for the adjustment of subcarrier phase between the input video signal (GEN LOCK IN) and output video signal (VBS OUT). The SC phase can be selected to 0d or 180d. Factory setting : 0d - . S801 (OUTPUT 2 SELECT) . R/G/B . Y/R-Y/B-Y . Y/C This switch selects the signals of the G/R/B, Y/R-Y/B-Y, and Y/C to output the OUTPUT 2 connectors on the CCU rear panel. Factory setting : R-Y/Y/B-Y - . S1000 (SEQ ON +/_) Set this switch to + or _ position according to the waveform monitor to be used. + : NPN open collector output _ : PNP open collector output Factory setting : + - . S800 (OUTPUT 1 SELECT) . R/G/B . Y/R-Y/B-Y . Y/C This switch selects the signals of the G/R/B, Y/R-Y/B-Y, and Y/C to output the OUTPUT 1 connectors on the CCU rear panel. Factory setting : R-Y/Y/B-Y CCU-TX7 (E)/V1 2-11 Downloaded from www.Manualslib.com manuals search engine DU-33 board [For the Serial No. 10601 and Higher (UC)] [For the Serial No. 40251 and Higher (CE)] |OFF ON|| |---|---| |CN1 S1 RV1|CN3 CN4 S4| ||| |. S1 (WIDE ID ON/OFF)|CALL ON CH1| |Set this switch to ON position when the 16:9 compatible|S1 S3 PRI VATE| |camera is connected and used in the 16:9 mode.|ON S2 OFF RV1 CH2 RV2| |Factory setting : ON|OFF S5| # AU-234 board CARBON DINAMIC AU-234 Board (A SIDE) - . S5 (DYNAMIC/CARBON) Set this switch according to the type of the headset microphone connected to the INTERCOM connector on the front panel. DYNAMIC : Dynamic type microphone CARBON : Carbon type microphone Factory setting : DYNAMIC 1. -12 Downloaded from www.Manualslib.com manuals search engine CCU-TX7 (E)/V1 # SDI-44 board TP810 ## SDI-44 RV1401 RV1400 ALARM B-Y DC B-Y LEVEL TP1400 D201 S701 LOCK FREE RV1501 RV1500 RV701 R-Y DC R-Y LEVEL TP1500 TP702 CN2 S601 OPE ADJ TP1201 E201 TP1300 RV1301 RV1300 Y DC Y LEVEL TP701 CN3 AUTO LEVEL (BARS) E1001 SDI POWER ON OFF RV904 RV903 TP902 RV901 TP901 RV902 SDI-44 Board (A SIDE) - . S701 (for factory adjustment) Factory setting: LOCK - . S601 (ADJ/OPE) This switch is used for returning the level control values of the R-Y and B-Y video signals to the factory setting. Set this switch to ADJ position and turn on the power to the main unit. Alternatively, set this switch to ADJ position and press the AUTOLEVEL (BARS) switch. Usually, set this switch to OPE position. Factory setting : OPE - . S401 (AUDIO MODE) Set this switch sets to 4CH position when the units is connected to an equipment with cannot receive SDI audio in 2CH mode. It is impossible to send audio signals to channels 3 and 4 even if this switch is set to 4CH. Usually, set this switch to 2CH position. Factory setting : 2CH CCU-TX7 (E)/V1 2-13 Downloaded from www.Manualslib.com manuals search engine Downloaded from www.Manualslib.com manuals search engine # SECTION 3 SERVICE INFORMATION ## 3-1. BOARD LAYOUT IO-140 board CN-1327 board MB-693 board CN-1351 board SDI-44 board (DXBK-701) CN-1325 CT-181 board board AA-90 board YD-26 board ES-20 board ## 3-2. DISASSEMBLY/INSTALLATION OF MAIN PART ## 3-2-1. Removal of Cabinet 2. ## Step shaft +K 3x6 CCU-TX7(E)/V1 3-1 (1) Removal of Front Panel 1. Front panel CN-1328 board CN-1350 board SW-892 board (COU-TX7) board Switching regulator AU-234 Loosen two coin screws Connector Connector AU-234 board Front panel Downloaded from www.Manualslib.com manuals search engine # (2) Removal of Cover Top cover 1. Remove four screws (K3x6) and disconnect CN1 on the IO-140 board and CN10, CN19 and CN20 on the MB- 693 board. Remove the rear panel. B 3x5 Connector (CN10) B 3x5 MB-693 board Connector (CN1) IO-140 board B 3x5 K 3x6 Bottom cover B 3x5 Connector (CN19) Connector (CN20) Rearpanel ## 3-2-2. Replacement of Switching Regulator [For the Serial No. 10001 through 11000 (UC)] [For the Serial No. 40001 through 41000 (CE)] 1. Remove the top and bottom covers. (Refer to "3-2-1. Removal of Cabinet".) K 3x6 B 4x5 B 4x5 B 4x5 Switching regulator 1. Remove six screws (B4x5) and switching regulator. 3-2 Downloaded from www.Manualslib.com manuals search engine 4. When installing a new switching regulator, reverse the above procedures. CCU-TX7(E)/V1 [For the Serial No. 11001 and Higher (UC)] [For the Serial No. 41001 and Higher (CE)] 1. Remove the top cover. (Refer to "3-2-1. Removal of Cabinet".) 2. Remove four screws (K3x6) and disconnect CN1 on the IO-140 board and CN10, CN19, CN20 and CN28 on the MB-693A board. Remove the rear panel. 3. Remove four screws (PSW3x20) and remove the fan. Fan PSW 3x20 A Connector (CN10) Connector (CN1) IO-140 board MB-693A board K 3x6 A Connector (CN28) Connector (CN19) Rearpanel K 3x6 Connector (CN20) 4. Remove six screws (B4x5) and switching regulator. B 4x5 B 4x5 B 4x5 Switching regulator # 3-2-3. Replacement of Fan [For the Serial No. 11001 and Higher (UC)] [For the Serial No. 41001 and Higher (CE)] - n - . When the fan is out of order, the CAMERA POWER indicator is blinking. Turn off the power immediately and replace the fan. Using the defective fan may reduce the service life of the equipment extremely. - . Before replacing the fan, be sure to turn off the power switch and unplug the power cord. 1. Perform steps 1 to 3 in Section "3-2-2. Replacement of Switching Regulator" for the Serial No. 11001 and higher (UC), Serial No. 41001 and higher to remove the fan. 2. Install a new fan in the reverse order. # 3-2-4. Removal of COU-TX7 As for installing of COU-TX7, refer to "Installing the Camera Operation Unit" of service manual SECTION 1. 5. When installing a new switching regulator, reverse the above procedures. CCU-TX7(E)/V1 3-3 Downloaded from www.Manualslib.com manuals search engine # 3-3. CIRCUIT DESCRIPTION ## CT-181 board CT-181 board employs RF system circuit that is consists of RETURN VIDEO modulation circuit and PROMPT VIDEO modulation circuit (It becomes AUX VIDEO demodulation circuit by switching.) and microcomputer system circuit that controls the system. Microcomputer system circuit section : The program is written in the ROM (IC1022) that is inserted to socket (CNI 1). ROM of built-in microcomputer is not used. Input and output of control signals between each board in CCU (included in COU) and each board are performed by serial data of 16 bit via I/O EXPANDER (IC1028). There are four communication channels with outside. The SCI-1 and SCI-2 built-in microcomputer communicate with CA (via modulation and demodulation circuit ) and RCP (via RS-232C driver). The external SCI (IC1024 and 1025) communicates with command link (RS-232C-1 and RS-232C-2 on the rear panel). The RF system circuit section : RETURN VIDEO modulation circuit frequency-modulates the input signal (VBS) from RETURN VIDEO 1 or 2, and sends to the CA. Change of RETURN VIDEO 1 or 2 is switched by RETURN 1 and 2 changing switch on the CA. The PROMPT VIDEO modulation circuit amplitude- modulates the input signal (VBS) from PROMPT VIDEO on the rear panel, and sends to the CA. The PROMPT VIDEO modulation circuit becomes AUX VIDEO demodulation circuit by switching S2002 and connecting RF coaxial cable to CN3 and CN8. (It is needed to change on the YD-25 board of CA.) Demodulated AUX VIDEO is outputted from PROMPT VIDEO on the rear panel. ## AA-90 board This board demodulates the RF signal of MIC1, MIC2, INCOM, CAM DATA and TONE sent from the CA, modulates a PGM signal, the INCOM signal and control data send to the CA. And also, this board switches the INCOM line, and switches the input /output of each audio signals. 3-4 Downloaded from www.Manualslib.com manuals search engine ## YD-26 board YD-26 board demodulates Y, R-Y, B-Y, CAM SYNC and SKIN GATE. This circuit consists of cable length detection circuit, cable length compensation circuit and these demodulation circuits. The cable length detection detects from amplitude of Y modulated wave. In accordance with this, the cable compensation circuit compensates the amplitude and phase matching as cable length to modulated wave of Y or differential signal. After that, they are respectively demodulated in demodulator circuit. ## ES-20 board This board produces VBS and RGB signal from the Y, R-Y, and B-Y signals sent from the YD-26 board, switches these signals, and outputs them as WF and PIX signals. This board also generates each sync signal and color bars signal. ## AU-234 board This board inputs and outputs an INCOM signal on the front panel, displays tally signals, and turns on and off the power of camera. ## IO-140 board This board mixes the RF signal between CA and CCU with the power of the camera. ## SDI-44 board (DXBK-701) This board converts the analog video/audio signals into digital signals and outputs them as SDI signals. Video signal processing : Y, R-Y and B-Y signals sent from the ES-20 board are converted from analog to digital and subject to the double over-sampling process on the digital filter IC308. Audio signal processing : MIC1 and MIC2 signals sent from the AA-90 board are converted from analog to digital and subject to 64 times over-sampling process on IC904 and then subject to time- base compression on IC404. These digital video signals and the time-base compressed digital audio signals are mixed on IC413. After that, the parallel data is converted to serial data on IC702 and output from this board. CCU-TX7(E)/V1 # 3-4. EXTENSION OF DXBK-701 (SDI-44 BOARD) 1. Disconnect two coaxial cables from the SDI-44 board. 2. Extend the SDI-44 board with the EX-564 board. To confirm the SDI signal output with the SDI- 44 board extended: Preparation: 1 Coaxial connector converter : Sony part No. 1-750-881-11 2 Coaxial cable assembly : Sony part No. 1-765-112-12 3 BNC cable : BELDEN 8281 cable or equivalent Connect 1 Coaxial cable assembly, 2 Coaxial connector converter, and 3 BNC cable as shown below. Coaxial cables SDI-44 board EX-564 board 2 Coaxial cable assembly 1 Coaxial connector converter 3 BNC cable Equipment, Monitor CCU-TX7(E)/V1 3-5 Downloaded from www.Manualslib.com manuals search engine Downloaded from www.Manualslib.com manuals search engine # SECTION 4 ADJUSTMENT ## 4-1. Preparation ## 4-1-1. Equipment Required - . Oscilloscope (more than 300 MHz) Tektronix 2465 or equivalent - . Waveform monitor/Vectorscope Tektronix 1765 or equivalent . Color monitor Sony PVM-1354Q or equivalent (For NTSC) Sony PVM-1454QM or equivalent (For PAL) - . Video signal generator Tektronix 1410 or equivalent (For NTSC) Tektronix 1411 or equivalent (For PAL) (Color Bar signal, 10 STEP signal, SWEEP signal) . Video camera Sony DXC-637 or DXC-D30 (NTSC) Sony DXC-637P or DXC-D30P (PAL) . Remote control Unit Sony RCP-TX7 (or COU-TX7 : Camera Operation Unit) . Digital voltmeter . Frequency counter . Audio generator . Spectrum analyzer . TRIAX Cable ## 4-1-2. Fixture Sony part number : Sony part number : J-6276-420-A J-6276-430-A Extension board EX-564 (For CCU-TX7/TX7P) Extension board EX-565 (For CA-TX7) |||AA-90 S201|0 dBu| |---|---|---|---| |||S301|0 dBu| |||S2002|4W| |||S2003|2CH| |||S2004|OFF| |Pattern box PTB-500||S2005|RTS| |||S2006|OFF| |Sony part number :||S2081|0 dBu| ||||| |.|||| ||||| |||S3|ON| |||S4|ON| |||ES-20 S1|20H (NTSC only)| |||S2|⋅⋅⋅| |||S3|0°| |||S800|R-Y/Y/B-Y| |||S801|R-Y/Y/B-Y| |||S1000|+| ## 4-1-3. Notes on Adjustment ## CAUTION - . When performing STAIR CASE adjustment, connect the WF MODE connector of CCU-TX7/TX7P rear panel to the remote control connector of waveform monitor with the connecting cord. (Refer to Section 2, 2-2. "Making of WF MODE Connection") - . Do not turn the following adjusting core on the YD-26 and CT-181 boards. Replace a new one when a filter is faulty. Filters on the YD-26 board and CT-181 board FL1, FL2, FL4, FL5, FL6, FL7, FL8, FL9, FL10, FL11, FL12, FL13, FL14, FL15 The adjustment is not required after replacing. ## 4-1-4. Switch settings When switching the following switches from a customer-set position, it is recommended to record the setting state of the customer in the table below. After adjustment is complete, be sure to return the switches to their customer-set position. |Board Switch|Setting during Customer-set| |---|---| ||adjustment position| |CT-181 S1000|All OFF| |S1001|REMOTE| |S1002|NORMAL| |S1004|All RS-232C side| |S2002|TX| |S2011|POWER| |S2012|POWER| |S2013|DC 24 V| |S2014|DC 24 V| CCU-TX7 (E)/V1 4-1 Downloaded from www.Manualslib.com manuals search engine # 4-1-5. Connections CAMERA ADAPTOR CA-TX7/TX7P TRIAX CABLE (30~750m) COLOR VIDEO CAMERA 1. -D30/D30P DXC-637/637P Waveform monitor A-ch PIX Vector scope CCA-7 CABLE 75Z |Color monitor|75Z| |---|---| |connections Audio generator RCP-TX7 Audio generator|| |LEVEL 600Z ADJ (X) LEVEL 600Z ADJ|| ||| CAMERA CONTROL UNIT CCU-TX7/TX7P (CAMERA OPERATION UNIT COU-TX7/TX7P) ## Audio Fig-1 Fig-2 1. (Y) GND 4-2 Downloaded from www.Manualslib.com manuals search engine CCU-TX7 (E)/V1 # 4-2. Video Signal System Adjustment ## 4-2-1. Sub-carrier Frequency Check Note : Check that the GEN LOCK IN connector of CCU- TX7/TX7P rear panel is no signal. Before adjustment, warm up the frequency counter more than 30 minutes. Equipment : Oscilloscope, Frequency counter To be extended : ES-20 board Adjustment Procedure : 1. Connect the oscilloscope and the frequency counter as follows. ## 4-2-2. CAM H Phase Adjustment Equipment : Oscilloscope (CHOP mode) To be extended : ES-20 board Preparation : . S800 (R/G/B, Y/R-Y/B-Y, Y/C)/ES-20 board → "Y/R-Y/B-Y" (Center position) Test point : CH1 pin 94/extension board CH2 pin 47/extension board Adjusting point :1RV1 (CAM H PHASE) /ES-20 board Specification :T = 0 ±0.05 µs 50% CH1 50% T CH2 2. Test point : TP1 (GND: E1) /ES-20 board Adjusting point :1RV4 (SC FREQ.)/ES-20 board Specification : [For NTSC] 3,579,545 ±2 Hz [For PAL] 4,433,619 ±2 Hz Y LEVEL (VBS) SYNC LEVEL (VBS) RV804 CHROMA LEVEL RV810 SYNC WIDTH RV3 RV2 SYNC PHASE RV803 RV802 E3 ES-20 PHASE H Y LEVEL(COMP) RV800 Y SETUP LEVEL (NTSC ONLY) RV801 SYNC LEVEL(COMP) RV7 H PHASE RV6 SC PHASE SC RV4 TP1 SC FREQUENCY 0 180° RV812 B-Y LEVEL RV5 SC-H PHASE OUT PUT 1 R/G/B Y/R-Y/B-Y Y/C OUT PUT 2 R/G/B Y/R-Y/B-Y Y/C E1 G MAT BAL2 B WHT BAL R WHT BAL RV506 RV505 RV500 S1 TP501 RV508 RV507 G MAT BAL1 G LEVEL TP502 R MAT BAL RV509 RV510 R LEVEL TP503 B MAT BAL RV512 RV513 B LEVEL TP7 TP5 TP4 TP2 TP3 ## R-Y BLK BAL RV501 POSITION RV511 R DC BAL ## R-Y GAIN ADJ RV502 RV1000 LEVEL RV514 B DC BAL RV504 RV503 B-Y GAIN ADJ B-Y BLK BAL ES-20 Board (A SIDE) CCU-TX7 (E)/V1 4-3 Downloaded from www.Manualslib.com manuals search engine # 4-2-3. H Phase Adjustment Equipment : Oscilloscope (CHOP mode) Video signal generator (Color Bar signal) To be extended : ES-20 board Preparation : - . Gen-lock . - . Input color bar signal of video signal generator to the GENLOCK connector on the CCU-TX7/TX7P. Test point : CH1 pin 78 (GND : pin 77)/ extension board CH2 pin 100 (GND: pin 99)/ extension board Adjusting point :1RV7 (H PHASE)/ES-20 board Adjustment Procedure : 1. Adjust 1RV7 (H PHASE)/ES-20 board so that the width T1 is 0 ±0.1 µs. 50% Pin 78 (CH-1) T1 Pin 100 (CH-2) ## 4-2-4. SYNC Phase Adjustment : Overall white (white portion of the pattern box) : Waveform monitor : ES-20 board Object Equipment To be extended Preparation : - . Adjust the zoom control at "TELE" so that the white pattern feame matches the underscanned picture frame on the screen. - . In case of RCP-TX7 IRIS AUTO Button (Control panel) → "ON" - . In case of COU-TX7 IRIS AUTO/MANUAL switch (Control panel) → "AUTO" Test point : VBS 1 OUT connector/CCU rear panel Adjusting point : 1RV2 (SYNC PHASE)/ES-20 board 1RV3 (SYNC WIDTH)/ES-20 board 1S2 (H BLKG)/ES-20 board Specification : [For NTSC] T1 = 1.35 ±0.1 µs (1RV2) T2 = 4.7 ±0.1 µs (1RV3) T3 = 10.9 ±0.1 µs (1S2) [For PAL] T1 = 1.55 ±0.1 µs (1RV2) T2 = 4.7 ±0.1 µs (1RV3) T3 = 12.0 ±0.1 µs (1S2) [For NTSC] |T3 20IRE 20IRE 4IRE 50% T1 T2||T3 350mV 350mV 50% T1 T2| |---|---|---| [For PAL] 4-4 Downloaded from www.Manualslib.com manuals search engine CCU-TX7 (E)/V1 # 4-2-5. INT SC Phase Adjustment Note : The SC-H phase measurement equipment (Tektronix : Waveform monitor 1765 or equivalent) is used for this adjustment. In case of using another measurement equipment, read its instruction manual carefully and then perform the following adjustment. Equipment : SC-H phase measurement equipment To be extended : ES-20 board Preparation : - . Set the mode of Textronix 1765 to "SC-H" mode. - . Make sure that the video signal is not inputted to the GEN LOCK connector on the CCU-TX7/TX7P rear panel. Test point : VBS 1 OUT/CCU rear panel Adjustment Procedure : ## [For NTSC] |YL g R G|MG Cy B|R g 75% YL yl G r|cy V MG b U B Cy mg| |---|---|---|---| ## [For PAL] . Adujst 1RV5 (SC-H PHASE)/ES-20 board so that the luminance line of BURST (SC) is the same as following figure. ## 4-2-6. Y CLAMP Adjustment Equipment : Oscilloscope To be extended : ES-20 board Preparation : . Select the BARS mode on the RCP-TX7 or COU-TX7. Test point : TP507 (GND : E1)/ES-20 board Adjusting point :1RV515 (Y CLAMP)/ES-20 board Specification :A = 0 ±5 mV [For NTSC] |A|||A|| |---|---|---|---|---| |||||| [For PAL] Note : After this adjustment is completed, set the mode of Tektronix Waveform monitor 1765 to "WFM" mode. Y LEVEL (VBS) SYNC LEVEL (VBS) RV804 CHROMA LEVEL RV810 SYNC WIDTH RV3 RV2 SYNC PHASE RV803 RV802 E3 ES-20 PHASE H Y LEVEL(COMP) RV801 SYNC LEVEL(COMP) RV7 H PHASE RV800 Y SETUP LEVEL (NTSC ONLY) RV6 SC PHASE SC RV4 TP1 SC FREQUENCY 0 180° RV812 B-Y LEVEL RV5 SC-H PHASE OUT PUT 1 R/G/B Y/R-Y/B-Y Y/C OUT PUT 2 R/G/B Y/R-Y/B-Y Y/C E1 G MAT BAL2 B WHT BAL R WHT BAL RV506 RV505 RV500 S1 TP501 RV508 RV507 G MAT BAL1 G LEVEL TP502 R MAT BAL RV509 RV510 R LEVEL TP503 B MAT BAL RV512 RV513 B LEVEL TP7 TP5 TP4 TP2 TP3 ## R-Y BLK BAL RV501 POSITION RV511 R DC BAL ## R-Y GAIN ADJ RV502 RV1000 LEVEL RV514 B DC BAL RV504 RV503 B-Y GAIN ADJ B-Y BLK BAL ES-20 Board (A SIDE) CCU-TX7 (E)/V1 4-5 Downloaded from www.Manualslib.com manuals search engine # 4-2-7. Y OUT (COMP) Level Adjustment ## 4-2-8. Y OUT (VBS) Level Adjustment Equipment : Waveform monitor To be extended : ES-20 board Preparation : - . Select the BARS mode on the RCP-TX7 or COU-TX7. - . S800 (R/G/B, Y/R-Y/B-Y, Y/C)/ES-20 board → "Y/R-Y/B-Y" (Center position) Test point : G/Y/Y 1 OUT connector /CCU rear panel Equipment : Waveform monitor To be extended : ES-20 board Preparation : - . Select the BARS mode on the RCP-TX7 or COU-TX7. - . S800 (R/G/B, Y/R-Y/B-Y, Y/C)/ES-20 board → "Y/C" Test point : G/Y/Y 1 OUT connector/CCU rear panel Adjustment Procedure : Adjustment Procedure : ES-20 board [For NTSC] ES-20 board [For NTSC] Adjusting point Specifications Adjusting point Specifications Y Level Adjustment 1RV804 A = 100 ±2 IRE Y Level Adjustment 1RV802 A = 100 ±2 IRE SYNC Level Adjustment 1RV803 B = 40 ±1 IRE SYNC Level Adjustment 1RV801 B = 40 ±1 IRE 1RV800 C = 7.5 ±1 IRE SET-UP Level Adjustment ES-20 board [For PAL] ES-20 board [For PAL] Y Level Adjustment SYNC Level Adjustment Adjusting point Specifications 1RV802 A = 700 ±10 mV ±5 mV 1RV801 B = 300 Y Level Adjustment SYNC Level Adjustment Adjusting point Specifications 1RV804 A = 700 ±10 mV 1RV803 B = 300 ±5 mV [For NTSC] [For PAL] [For NTSC] |||||||||||A||||A||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |||||||||||||||||| [For PAL] B B C ES-20 Board (A SIDE) 4-6 B B Y LEVEL (VBS) SYNC LEVEL (VBS) RV804 CHROMA LEVEL RV810 SYNC WIDTH RV3 RV2 SYNC PHASE RV803 RV802 E3 ES-20 PHASE H Y LEVEL(COMP) RV801 SYNC LEVEL(COMP) RV800 Y SETUP LEVEL (NTSC ONLY) RV7 H PHASE RV6 SC PHASE SC RV4 TP1 SC FREQUENCY 0 180° RV812 B-Y LEVEL RV5 SC-H PHASE OUT PUT 1 R/G/B Y/R-Y/B-Y Y/C OUT PUT 2 R/G/B Y/R-Y/B-Y Y/C E1 G MAT BAL2 B WHT BAL R WHT BAL RV506 RV505 RV500 S1 TP501 RV508 RV507 G MAT BAL1 G LEVEL TP502 R MAT BAL RV509 RV510 R LEVEL TP503 B MAT BAL RV512 RV513 B LEVEL TP7 TP5 TP4 TP2 TP3 ## R-Y BLK BAL RV501 POSITION RV511 R DC BAL ## R-Y GAIN ADJ RV502 RV1000 LEVEL RV514 B DC BAL RV504 RV503 B-Y GAIN ADJ B-Y BLK BAL Downloaded from www.Manualslib.com manuals search engine CCU-TX7 (E)/V1 # 4-2-9. R-Y/B-Y White Black Balance Adjustment Equipment : Oscilloscope To be extended : ES-20 board Preparation : - . Select the BARS mode on the RCP-TX7 - r COU-TX7. Adjustment Procedure : 1. Test point : TP505 (GND : E1)/ES-20 board Specification :A = 0 ±5 mV 1RV500 C = 0 ±5 mV 1RV501 E = 525 ±5 mV p-p 1RV502 CA E 2. Test point : TP506 (GND : E1)/ES-20 board Specification : B = 0 ±5 mV 1RV505 D = 0 ±5 mV 1RV503 F = 525 ±5 mV p-p 1RV504 DB F 3. Repeat procedure 1 and 2 several times. ## 4-2-10. G Level Adjustment Equipment : Waveform monitor To be extended : ES-20 board Preparation : - . Select the BARS mode on the RCP-TX7 or COU-TX7. - . S800 (R/G/B, Y/R-Y/B-Y, Y/C)/ES-20 board → "R/G/B" Adjustment Procedure : 1. Test point : G/Y/Y1 OUT connector/CCU rear panel Adjusting point :1RV507 (G MAT BAL1)/ES-20 board 1RV506 (G MAT BAL2)/ES-20 board Specification :A = B = 0 +7 _0 mV [For NTSC] A = B = 0 +7 _0 mV [For PAL] RV507 RV506 B A 2. Adjusting point :1RV508 (G LEVEL)/ES-20 board Specification : C = 700 ±10 mV [For NTSC] C = 700 ±10 mV [For PAL] [For NTSC] [For PAL] C C CCU-TX7 (E)/V1 4-7 Downloaded from www.Manualslib.com manuals search engine # 4-2-11. R Level Adjustment Equipment : Waveform monitor To be extended : ES-20 board Preparation : - . Select the BARS mode on the RCP-TX7 or COU-TX7. - . S800 (R/G/B, Y/R-Y/B-Y, Y/C)/ES-20 board → "R/G/B" Adjustment Procedure : 1. Test point : R/R-Y/C 1 OUT connector/CCU rear panel Adjusting point :1RV509 (R MAT BAL)/ES-20 board Specification :A = 0 +7 _0 mV [For NTSC] A = 0+7 _ mV [For PAL] [For NTSC] |||||||||||| |---|---|---|---|---|---|---|---|---|---|---| |A|||||A||A||A|| [For PAL] ## 4-2-12. B Level Adjustment Equipment : Waveform monitor To be extended : ES-20 board Preparation : - . Select the BARS mode on the RCP-TX7 or COU-TX7. - . S800 (R/G/B, Y/R-Y/B-Y, Y/C)/ES-20 board → "R/G/B" Adjustment Procedure : 1. Test point : B/B-Y 1 OUT connector/CCU rear panel Adjusting point : 1RV512 (B MAT BAL)/ES-20 board Specification :A = 0+7 _ mV [For NTSC] A = 0+7 _ mV [For PAL] [For NTSC] [For PAL] 2. Adjusting point :1RV510 (R LEVEL)/ES-20 board Specification : B = 700 ±10 mV [ For NTSC] B = 700 ±10 mV [ For PAL] [For NTSC] ||B|||B|||B||B|| |---|---|---|---|---|---|---|---|---|---|---| [For PAL] 2. Adjusting point : 1RV513 (B LEVEL)/ES-20 board Specification : B = 700 ±10 mV [For NTSC] B = 700 ±10 mV [For PAL] [For NTSC] [For PAL] Y LEVEL (VBS) SYNC LEVEL (VBS) RV804 CHROMA LEVEL RV810 SYNC WIDTH RV3 RV2 SYNC PHASE RV803 RV802 E3 ES-20 PHASE H Y LEVEL(COMP) RV801 SYNC LEVEL(COMP) RV7 H PHASE RV800 Y SETUP LEVEL (NTSC ONLY) RV6 SC PHASE SC RV4 TP1 SC FREQUENCY 0 180° RV812 B-Y LEVEL RV5 SC-H PHASE OUT PUT 1 R/G/B Y/R-Y/B-Y Y/C OUT PUT 2 R/G/B Y/R-Y/B-Y Y/C E1 G MAT BAL2 B WHT BAL R WHT BAL RV506 RV505 RV500 S1 TP501 RV508 RV507 G MAT BAL1 G LEVEL TP502 R MAT BAL RV509 RV510 R LEVEL TP503 B MAT BAL RV512 RV513 B LEVEL TP7 TP5 TP4 TP2 TP3 ## R-Y BLK BAL RV501 POSITION RV511 R DC BAL ## R-Y GAIN ADJ RV502 RV1000 LEVEL RV514 B DC BAL RV504 RV503 B-Y GAIN ADJ B-Y BLK BAL 4-8 Downloaded from www.Manualslib.com manuals search engine ES-20 Board (A SIDE) CCU-TX7 (E)/V1 # 4-2-13. WF OUT R/B DC OFFSET Adjustment Equipment :Waveform monitor To be extended : ES-20 board Preparation : . Select the BARS mode on the RCP-TX7. Test point : WF OUT connector/CCU rear panel Adjustment Procedure : . Adjust 1RV511 (R DC BAL), 1RV514 (B DC BAL)/ES- 20 board so that the DC levels of "R" and "B" are same as that of "G" even after the MONITOR SELECT button / RCP-TX7 is selected "R", "G" and "B". Specification : DC level ±1 mV ("G") ## 4-2-14. Carrier Balance Adjustment Equipment : Vectorscope (MAX GAIN) To be extended : ES-20 board Preparation : . Select the BARS mode on the RCP-TX7 or COU-TX7. Test point : VBS 1 OUT connector/CCU rear panel Adjustment Procedure : [For NTSC] |YL g R G|MG Cy B|g YL yl R 75% G r|cy V MG b U B Cy mg| |---|---|---|---| [For PAL] . Adjust 1RV805 (I (V) CAL) and 1RV809 (Q(U) CAL)/ ES-20 board so that the luminance point of black level is located in the center of the vectorscope. CCU-TX7 (E)/V1 4-9 Downloaded from www.Manualslib.com manuals search engine # 4-2-15. Color Vector Adjustment Equipment : Vectorscope, Waveform monitor To be extended : ES-20 board Preparation : - . GAIN Switch/vectorscope → "75% CAL" - . Adjust the PHASE control on the vectorscope so that the burst spot is aligned to the 75% axis. - . Select the BARS mode on the RCP-TX7 or COU-TX7. Test point : VBS 1 OUT connector/ CCU rear panel Adjustment Procedure : 1. Adjust 1RV806 (BURST LEVEL)/ES-20 board so that the burst spot is located at 75% scale mark on the vectorscope screen. 2. Adjust the following adjusting controls so that all luminance points are inside the respective "4" mark on the vectorscope. 1RV807 (BURST PHASE)/ES-20 board 1RV808 ((U) LEVEL)/ES-20 board 1RV810 (CHROMA LEVEL)/ES-20 board 1FL800 (QUAD)/ES-20 board [For NTSC] [For PAL] cy g R R g MG MG 75% V 100% YL YL b U yl B B G G ## R-Y OUT Cy Cy mg r 3. Repeat procedure 1 and 2 several times. ## 4-2-16. R-Y/B-Y OUT Level Adjustment Equipment : Oscilloscope To be extended : ES-20 board Preparation : - . Select the BARS mode on the RCP-TX7 or COU-TX7. - . S800 (R/G/B, Y/R-Y/B-Y, Y/C)/ES-20 board → "Y/R-Y/B-Y" (Center position) - . R/R-Y/C1 OUT connector/CCU rear panel → "75 Z termination" - . B/B-Y1 OUT connector/CCU rear panel → "75 Z termination" Adjustment Procedure : ES-20 board [For NTSC (UC)] Test point (GND : pin 91) Adj. point Specifications 1. -Y pin 92 1RV811 A = 700 ±5 mV p-p B-Y pin 90 1RV812 B = 700 ±5 mV p-p ES-20 board [For PAL] Test point (GND : pin 91) Adj. point Specifications 1. -Y pin 92 1RV811 A = 525 ±5 mV p-p B-Y pin 90 1RV812 B = 525 ±5 mV p-p ## B-Y OUT A B 4-10 Downloaded from www.Manualslib.com manuals search engine CCU-TX7 (E)/V1 # 4-2-17. VBS OUT Level Adjustment Equipment :Waveform monitor To be extended : ES-20 board Preparation : . Select the BARS mode on the RCP-TX7 or COU-TX7. Test point : VBS 1 OUT connector/CCU rear panel Adjusting point :1RV813 (VBS LEVEL)/ES-20 board Specification :A = 100 ±1 IRE [For NTSC] A = 700 ±10 mV [For PAL] [For NTSC] [For PAL] A A ## 4-2-18. STAIR CASE Adjustment Note : This adjustment is for temporary adjustment when repairing the STAIR CASE block. In the system set up, the readjustment is required to match the characteristic of waveform monitor. Equipment : Oscilloscope To be extended : ES-20 board Preparation : - . Select the BARS mode on the RCP-TX7. - . MONITOR SELECT button/RCP-TX7 → "SEQ" Test point : pin 76 (GND: pin 75)/ extension board Adjusting point :1RV1001/ES-20 board 1RV1000/ES-20 board Specification :A = 10.0 ±1 V p-p (1RV1001) B = 0 ±1 V dc (1RV1000) A B GND Y LEVEL (VBS) SYNC LEVEL (VBS) RV804 CHROMA LEVEL RV810 SYNC WIDTH RV3 RV2 SYNC PHASE RV803 RV802 Y LEVEL(COMP) RV801 FL800 SYNC LEVEL (COMP) E3 ES-20 PHASE H RV7 H PHASE RV800 Y SETUP LEVEL (NTSC ONLY) SC RV6 SC PHASE RV4 TP1 SC FREQUENCY 0 180° RV812 B-Y LEVEL RV5 SC-H PHASE OUT PUT 1 R/G/B Y/R-Y/B-Y Y/C OUT PUT 2 R/G/B Y/R-Y/B-Y Y/C E1 G MAT BAL2 B WHT BAL R WHT BAL RV506 RV505 RV500 S1 TP501 RV508 RV507 G MAT BAL1 G LEVEL TP502 R MAT BAL RV509 RV510 R LEVEL TP503 B MAT BAL RV512 RV513 B LEVEL TP7 TP5 TP4 TP2 TP3 ## R-Y BLK BAL RV501 POSITION RV511 R DC BAL ## R-Y GAIN ADJ RV502 RV1000 LEVEL RV514 B DC BAL RV504 RV503 B-Y GAIN ADJ B-Y BLK BAL ES-20 Board (A SIDE) CCU-TX7 (E)/V1 4-11 Downloaded from www.Manualslib.com manuals search engine # 4-2-19. WIDE ID Level Adjustment [For the Serial No. 10601 and Higher (UC)] [For the Serial No. 40251 and Higher (CE)] Note : Before starting this adjustment, complete the adjustments as instructed in section 4-2-7, 4-2-8 and 4-2-17. Equipment : Waveform monitor To be extended : ES-20 board Preparation : - . Select the BARS mode on the RCP-TX7/TX7P or COU- TX7. S1/DU-33 board (on the ES-20 board) → ON - . Select the 16:9 mode. (How to select the 16:9 mode differs depending on the equipment connected to the unit.) [When the RCP-TX7/TX7P is connected] n For details, refer to the RCP-TX7/TX7P operating instruction. 1. Select the advanced setting mode. 2. Press the menu selector button "OTHERS" nine times. 3. Select 16:9 with the setting button. [When the COU-TX7 is connected] n For details, refer to the DXC-D30WS/D30WSP operating instruction. Switch 16:9/4:3 to the 16:9 setting mode using the advanced menu page 9 of the DXC-D30WS/D30WSP. Adjustment point: 1RV1/DU-33 board (on the ES-20 board) Adjustment Procedure : 1. Select the lines on the waveform monitor. 20 lines [NTSC] 23 lines [PAL] 2. Test point : VBS 1 OUT connector/CCU rear panel Specification :A = 70 ±5 IRE [For NTSC] A = 500 ±10 mV [For PAL] [For NTSC] [For PAL] A A 1H 1H CN1 OFF ON S1 1. -12 RV1 DU-33 Board (A SIDE) Downloaded from www.Manualslib.com manuals search engine CCU-TX7 (E)/V1 # 4-3. Y Cable Compensation System Adjustment ## 4-3-1. SYNC SEP Adjustment Equipment : Oscilloscope To be extended : YD-26 board Preparation : - . In case of RCP-TX7 Set IRIS AUTO button to "OFF", and close the lens iris by IRIS control knob. - . In case of COU-TX7 Set IRIS AUTO/MANUAL switch to "MANUAL", and close the lens iris by IRIS control knob. Test point : TP4 (GND: E2)/YD-26 board Adjusting point :1LV1 (Y RF TUNE)/YD-26 board Specification : Level "A" = maximum level ## 4-3-2. BLACK Pulse Width Adjustment Equipment : Oscilloscope To be extended : YD-26 board Test point : TP5 (GND: E2)/YD-26 board Adjusting point : 1RV2 (BLACK S/H)/YD-26 board Specification : T = 1.7 ±0.1 µs ||| |---|---| |H|| H A T 50% E1 RV1 Y AGC CONT SAMPL S/H E2 RV4 TP11 Y LEVEL RV9 E6 RV17 R-Y LEVEL TP2 TP5 TP8 TP4 TP7 Y RF TUNE TP6 RV2 RV5 LV1 BLACK S/H SYNC S/H TP3 S4 C 2'nd AGC E7 B-Y CARR BAL TP13 TP14 RV11 Y OFFSET ADJ RV8 YD-26 RV6 VCO DC SET Y 2'nd AGC S3 TP9 TP12 TP17 RV12 1. -Y LEVEL E8 E9 ## R-Y CARR BAL RV16 TP19 1. TP15 RV10 C AGC CONT RV18 90° SET RV13 RV14 RV15 OFFSET ADJ PLL SET C CAR LEV E16 TP1 E4 S2 CABLE LENGTH S1 E3 TP21 TP20 TP26 TP10 E5 SAMPL GATE RV3 YD-26 Board (A SIDE) CCU-TX7 (E)/V1 4-13 Downloaded from www.Manualslib.com manuals search engine # 4-3-3. SYNC Sample Hold Pulse Width Adjustment Equipment : Oscilloscope To be extended : YD-26 board Test point : TP8 (GND: E2)/YD-26 board Adjusting point :1RV5 (SYNC S/H)/YD-26 board Specification :T = 1.3 ±0.1 µs 50% T ## 4-3-4. 22.5 MHz VCO DC Set Adjustment Note : Make sure that 45MHz frequency on the YM-15 board (CA-TX7/TX7P) should be correct. Equipment : Oscilloscope To be extended : YD-26 board Test point : TP9 (GND: E2)/YD-26 board Adjusting point :1RV6 (VCO DC SET)/YD-26 board Specification :A = 0 ±30 mV dc GND A 4-14 Downloaded from www.Manualslib.com manuals search engine CCU-TX7 (E)/V1 # 4-3-5. Sample Pulse Width Adjustment Equipment : Oscilloscope To be extended : YD-26 board Test point : TP7 (GND: E2)/YD-26 board Adjusting point :1RV4 (SAMPLE S/H)/YD-26 board Specification :T = 40.0 ±2.0 µs || |---| |V| ## 4-3-6. Sample Pulse V Gate Width Adjustment Equipment : Oscilloscope To be extended : YD-26 board Test point : TP7 (GND: E2)/YD-26 board Adjusting point :1RV3 (SAMPLE GATE)/YD-26 board Adjustment Procedure : . Confirm that the sample pulses have six pulses in both odd and even fields. If not met, adjust 1RV3 (SAMPLE GATE)/YD-26 board so that the sample pulses have six pulses in both odd and even fields. 6 Pulses T 50% SAMPL GATE RV3 E1 RV1 Y AGC CONT SAMPL S/H E2 RV4 TP11 Y LEVEL RV9 E6 RV17 R-Y LEVEL TP2 TP5 TP8 TP4 TP7 Y RF TUNE TP6 RV2 RV5 LV1 BLACK S/H SYNC S/H TP3 S4 C 2'nd AGC E7 B-Y CARR BAL TP13 TP14 RV11 Y OFFSET ADJ RV8 YD-26 RV6 VCO DC SET Y 2'nd AGC S3 TP9 TP12 TP17 RV12 1. -Y LEVEL E8 E9 ## R-Y CARR BAL RV16 TP19 1. TP15 RV10 C AGC CONT RV18 90° SET RV13 RV14 RV15 OFFSET ADJ PLL SET C CAR LEV E16 TP1 E4 S2 CABLE LENGTH S1 E3 TP21 TP20 TP26 TP10 E5 YD-26 Board (A SIDE) CCU-TX7 (E)/V1 4-15 Downloaded from www.Manualslib.com manuals search engine # 4-3-7. 22.5 MHz Carrier Level Adjustment Equipment : Oscilloscope To be extended : YD-26 board Test point : TP10 (GND: E5)/YD-26 board Adjusting point :1RV7 (Y CARR LEVEL)/ YD-26 board Specification :A = 400 ±20 mV p-p (BW LIMIT/Oscilloscope → "OFF") || |---| || || A ## 4-3-8. Y DEMOD Carrier Balance Adjustment Equipment : Oscilloscope To be extended : YD-26 board Preparation : - . In case of RCP-TX7 Set IRIS AUTO button to "OFF", and close the lens iris by IRIS control knob. - . In case of COU-TX7 Set AUTO/MANUAL switch to "MANUAL", and close the lens iris by IRIS control knob. - . S3 (Y 2nd AGC)/YD-26 board → "OFF" Test point : TP11 (GND: E6)/YD-26 board Adjusting point :1RV8 (Y CARR BAL)/YD-26 board Specification :A = maximum level ||V| |---|---| A 4-16 Downloaded from www.Manualslib.com manuals search engine CCU-TX7 (E)/V1 # 4-3-9. Y OFFSET Adjustment Equipment : Oscilloscope To be extended : YD-26 board Test point : TP11 (GND: E6)/YD-26 board Adjusting point :1RV24 (Y OFFSET ADJ)/ YD-26 board Specification :A = 0 ±3 mV A BLKG SYNC ## 4-3-11. Y 1st AGC Adjustment Equipment : Oscilloscope To be extended : YD-26 board Preparation : - . S1 (AUTO/MANU)/YD-26 board → "AUTO" - . S3 (Y 2nd AGC)/YD-26 board → "OFF" Test point : TP11 (GND: E6)/YD-26 board Adjusting point :1RV1 (Y AGC CONT)/YD-26 board Specification :A = 700 ±20 mV A ## 4-3-10. Y 90˚ Adjustment Equipment : Oscilloscope To be extended : YD-26 board Preparation : . Select the BARS mode on the RCP-TX7 or COU-TX7. Test point : TP26 (GND: E6)/YD-26 board Adjusting point :1FL3 (90˚ SIFT)/YD-26 board Specification :A = 0 ±10 mV [For NTSC] ||A||A|| |---|---|---|---|---| [For PAL] CCU-TX7 (E)/V1 4-17 Downloaded from www.Manualslib.com manuals search engine # 4-3-12. Y Output Level Adjustment Equipment : Oscilloscope To be extended : YD-26 board Preparation : . S3 (Y 2nd AGC)/YD-26 board → "ON" Test point : TP11 (GND: E6)/YD-26 board Adjusting point :1RV9 (Y LEVEL)/YD-26 board Specification :A = 700 ±7 mV p-p A ## 4-4. CHROMA Cable Compensation System Adjustment ## 4-4-1. 45 MHz Carrier Level Adjustment Equipment : Oscilloscope To be extended : YD-26 board Test point : TP16 (GND: E8)/YD-26 board Adjusting point :1RV15 (C CARR LEVEL)/ YD-26 board Specification :A = 400 ±20 mV p-p (BW LIMIT/Oscilloscope → "OFF" ) A E1 RV1 Y AGC CONT SAMPL S/H E2 RV4 TP11 Y LEVEL RV9 E6 RV17 R-Y LEVEL TP2 TP5 TP8 TP4 TP7 Y RF TUNE TP6 RV2 RV5 LV1 BLACK S/H SYNC S/H TP3 S4 C 2'nd AGC E7 B-Y CARR BAL TP13 TP14 RV11 Y OFFSET ADJ RV8 YD-26 RV6 VCO DC SET Y 2'nd AGC S3 FL3 TP9 TP12 TP17 RV12 1. -Y LEVEL E8 E9 ## R-Y CARR BAL RV16 TP19 1. TP15 RV10 C AGC CONT RV18 90° SET RV13 RV14 RV15 OFFSET ADJ PLL SET C CAR LEV E16 TP1 E4 S2 CABLE LENGTH S1 E3 TP21 TP20 TP26 TP10 E5 SAMPL GATE RV3 YD-26 Board (A SIDE) 4-18 Downloaded from www.Manualslib.com manuals search engine CCU-TX7 (E)/V1 # 4-4-2. C PLL Set Adjustment Note : Make sure that 45 MHz frequency on the YM-15 board (CA-TX7/TX7P) is correct. Equipment : Oscilloscope To be extended : YD-26 board Test point : TP15 (GND: E8)/YD-26 board Adjusting point :1RV14 (PLL SET)/YD-26 board Specification :A = 0 ±30 mV dc || |---| || A GND ## 4-4-3. B-Y DEMOD Carrier Balance Adjustment Equipment : Oscilloscope To be extended : YD-26 board Preparation : . S4 (C 2nd AGC)/YD-26 board → "OFF" Test point : TP17 (GND: E8)/YD-26 board Adjusting point :1RV11 (B-Y CARR BAL)/ YD-26 board Specification : Adjust so that the waveform level of SAMPLE pulse is maximum. V Maximum E1 RV1 Y AGC CONT SAMPL S/H E2 RV4 TP11 Y LEVEL RV9 E6 RV17 R-Y LEVEL TP2 TP5 TP8 TP4 TP7 Y RF TUNE TP6 RV2 RV5 LV1 BLACK S/H SYNC S/H TP3 S4 C 2'nd AGC E7 B-Y CARR BAL TP13 TP14 RV11 Y OFFSET ADJ RV8 YD-26 RV6 VCO DC SET Y 2'nd AGC S3 TP9 TP12 TP17 RV12 1. -Y LEVEL E8 E9 ## R-Y CARR BAL RV16 TP19 1. TP15 RV10 C AGC CONT RV18 90° SET RV13 RV14 RV15 OFFSET ADJ PLL SET C CAR LEV E16 TP1 E4 S2 CABLE LENGTH S1 E3 TP21 TP20 TP26 TP10 E5 SAMPL GATE RV3 YD-26 Board (A SIDE) CCU-TX7 (E)/V1 4-19 Downloaded from www.Manualslib.com manuals search engine # 4-4-4. B-Y Crosstalk Adjustment Note : Make sure that 45 MHz frequency on the YM-15 board (CA-TX7/TX7P) is correct. Equipment : Oscilloscope To be extended : YD-26 board Test point : TP17 (GND: E8)/YD-26 board Adjusting point :1RV13 (OFFSET ADJ)/YD-26 board Specification :A = 0 ±3 mV |||| |---|---|---| |||| |||| ## 4-4-5. C 1st AGC Adjustment Equipment : Oscilloscope To be extended : YD-26 board Preparation : - . S1 (AUTO/MANU)/YD-26 board → "AUTO" - . S4 (C 2nd AGC)/YD-26 board → "OFF" Test point : TP17 (GND: E8)/YD-26 board Adjusting point :1RV10 (C AGC CONT)/YD-26 board Specification :A = 350 ±20 mV A BLKG SYNC A 4-20 Downloaded from www.Manualslib.com manuals search engine CCU-TX7 (E)/V1 # 4-4-6. B-Y OUT Level Adjustment Equipment : Oscilloscope To be extended : YD-26 board Preparation : . S4 (C 2nd AGC)/YD-26 board → "ON" Test point : TP17 (GND: E8)/YD-26 board Adjusting point :1RV12 (B-Y LEVEL)/YD-26 board Specification :A = 350 ±5 mV p-p A ## 4-4-7. R-Y DEMOD Carrier Balance Adjustment Equipment : Oscilloscope To be extended : YD-26 board Test point : TP18 (GND: E9)/YD-26 board Adjusting point :1RV16 (R-Y CARR BAL)/ YD-26 board Specification : Adjust 1RV16 so that the negative DC level is maximum. GND Maximum (Negative DC level) _ E1 RV1 Y AGC CONT SAMPL S/H E2 RV4 TP11 Y LEVEL RV9 E6 RV17 R-Y LEVEL TP2 TP5 TP8 TP4 TP7 Y RF TUNE TP6 RV2 RV5 LV1 BLACK S/H SYNC S/H TP3 S4 C 2'nd AGC E7 B-Y CARR BAL TP13 TP14 RV11 Y OFFSET ADJ RV8 YD-26 RV6 VCO DC SET Y 2'nd AGC S3 TP9 TP12 TP17 RV12 1. -Y LEVEL E8 E9 ## R-Y CARR BAL RV16 TP19 1. TP15 RV10 C AGC CONT RV18 90° SET RV13 RV14 RV15 OFFSET ADJ PLL SET C CAR LEV E16 TP1 E4 S2 CABLE LENGTH S1 E3 TP21 TP20 TP26 TP10 E5 SAMPL GATE RV3 YD-26 Board (A SIDE) CCU-TX7 (E)/V1 4-21 Downloaded from www.Manualslib.com manuals search engine # 4-4-8. R-Y Crosstalk Adjustment Note : Make sure that 45 MHz frequency on the YM-15 board (CA-TX7/TX7P) is correct. Equipment : Oscilloscope To be extended : YD-26 board Test point : TP19 (GND: E9)/YD-26 board Adjusting point :1RV18 (90° SET)/YD-26 board Specification : The SAMPLE pulse level should be minimum. A = 0 ±3 mV A ## 4-4-9. R-Y OUT Level Adjustment Equipment : Oscilloscope To be extended : YD-26 board Preparation : . S4 (C 2nd AGC)/YD-26 board → "ON" Test point : TP19 (GND: E9)/YD-26 board Adjusting point :1RV17 (R-Y LEVEL)/YD-26 board Specification :A = 350 ±5 mV || |---| || A V 4-22 Downloaded from www.Manualslib.com manuals search engine CCU-TX7 (E)/V1 # 4-5. RETURN VIDEO Cable Compensation System Adjustment ## 4-5-1. Return Video Carrier Frequency Adjustment Equipment : Spectrum analyzer To be extended : CT-181 board Preparation : . Input 10 STEP signal (sub-carrier : OFF) of video signal generator to RETURN-1 connector (75 Z termination, 1.0 V p-p) on the CCU-TX7/TX7P rear panel. Test point : TP21 (GND: E12)/CT-181 board Adjusting point :1CV1 (RET FREQ)/CT-181 board Specification : 69.000 ±0.005 MHz SYNC ## 4-5-2. Return Video Deviation Adjustment Equipment : Spectrum analyzer To be extended : CT-181 board Preparation : . Input 10 STEP signal (sub-carrier : OFF) of video signal generator to RETURN-1 connector (75 Z termination, 1.0 V p-p) on the CCU-TX7/TX7P rear panel. Test point : TP21 (GND: E12)/CT-181 board Adjusting point :1RV20 (RET DEV)/CT-181 board Specification :T = 2.000 ±0.005 MHz T ## 69.0MHz CENT FREQ: 69.0MHz FFEQ SPAN: 5.0MHz ## 69.0MHz CENT FREQ: 69.0MHz FFEQ SPAN: 5.0MHz Note : Performe the adjustment of 4-5-1. "Return Video Carrier Frequency Adjustment" when the SYNC portion is moved during the adjustment. E1001 TP2006 RET FREQ CV1 CT-181 Board (A SIDE) CCU-TX7 (E)/V1 4-23 E11 S2011 CT-181 R TALLY R TALLY CONTACT CONTACT POWER TP1000 POWER E12 DC24V RF AGC DLY RV22 PROMPT DEV RV21 S2013 DC24V TTL G TALLY CONTACT POWER E1000 TTL R TALLY CONTACT G TALLY POWER DC24V G TALLY TTL MIC 1 GAIN SW1000 SW1001 MIC 2 GAIN PROMPT FREQ S2012 RV23 PROMPT LEVEL PROMPT TUNE DC24V TTL S2014 CN2 LV3 E13 TP22 S2002 MIC GAIN NORM CH-1 MIN MAX NORM CH-2 MIN MAX PROMPT RF TX CN7 RET RF CN3 PROMPT RF PROMPT S1001 PANEL SELECT S1004 RX TX RS232C-2 CN8 PROMPT RF RX IF BOARD PANEL REMOTE TP1001 TP2000 LOCAL E16 TP2003 TP2002 TP2004 TP2001 CONTROL MODE NORMAL NORM CONT MODE SLAVE S1002 SLAVE TP2005 E2000 Downloaded from www.Manualslib.com manuals search engine # 4-6. PROMPT VIDEO Cable Compensation System Adjustment ## 4-6-1. TX PROMPT VIDEO Demodulation Adjustment Note : When performing this adjustment, the TRIAX cable less than 300 m should be used. Equipment :Waveform monitor, Video signal generator (10 STEP signal) To be extended : CT-181 board Preparation : - . S1 (AUX/PROMPT)/YD-25 board (CA-TX7/TX7P) → "PROMPT" . S6 (AUX/PROMPT)/YD-25 board (CA-TX7/TX7P) → "PROMPT" . Connect CN7 and CN3 on the CT-181 board. (CCU-TX7/ TX7P) . S2002 (TX ↔ RX)/CT-181 board (CCU-TX7/TX7P) → "TX" - . S1 (MODE AUTO/MAN)/YD-26 board (CCU-TX7/TX7P) → "AUTO" - . Input 10 STEP signal (sub-carrier : OFF) of video signal generator to PROMPT VIDEO IN connector (75 Z termination, 1.0 V p-p) on the CCU-TX7 /TX7P rear panel. Test point : PROMPTER OUT (CA-TX7/TX7P) Note :To measure the video level, make 75 Z termination on the waveform monitor side. Adjusting point :1RV21 (PROMPT DEV)/ CT-181 board Specification :A = 140 ±6 IRE [For NTSC] A = 1.00 ±0.05 V [For PAL] || |---| || || || || A Note : After this adjustment is completed, set as follows. - . S1 (MODE AUTO/MAN)/YD-26 board (CCU-TX7/TX7P) → "AUTO" 1. -24 Downloaded from www.Manualslib.com manuals search engine CCU-TX7 (E)/V1 # 4-6-2. RX PROMPT VIDEO Demod. Adjustment ## Note : - . Perform this adjustment only when replacing 1LV2 (PROMPT FREQ) or 1LV3 (PROMPT TUNE)/CT-181 board. When performing this adjustment, the TRIX cable less than 300 m should be used. - . Adjustment of CA-TX7/TX7P must be completed. Equipment :Waveform monitor, Video signal generator (10 STEP signal) To be extended : CT-181 board Preparation : - . S1 (AUX/PROMPT)/YD-25 board (CA-TX7/TX7P) → "AUX" - . S6 (AUX/PROMPT)/YD-25 board (CA-TX7/TX7P) → "AUX" - . Connect CN8 and CN3 on the CT-181board. (CCU-TX7/ TX7P) - . S2002 (TX ↔ RX)/CT-181 board (CCU-TX7/TX7P) → "RX" - . S1 (MODE AUTO/MAN)/YD-26 board (CCU-TX7/TX7P) → "AUTO" . Input the SWEEP signal of the video signal generator to PROMPTER OUT connector on the CA-TX7/TX7P rear panel. Test point : PROMPTER VIDEO IN connector (CCU-TX7/TX7P rear panel) Note : To measure the video level, make 75 Z termination on the waveform monitor side. Adjusting point :1LV2 (PROMPT FREQ)/ CT-181 board 1LV3 (PROMPT TUNE)/ CT-181 board ## Adjustment Procedure : 1. Observe the waveform monitor screen and adjust 1LV3 (PROMPT TUNE)/CT-181 board so that the video waveform is appeared. 2. Adjust 1LV2 (PROMPT FREQ)/CT-181 board so that the frequency response at 6 MHz portion is minimum. || |---| |6MHz| |3. Change the output| |10 STEP| |Re-adjust 1LV3| |the "A" portion at| |NOTE : If not met,| |VIDEO| |"4-6-3.| 1. of the video signal generator to (sub-carrier : ON) signal. 2. (PROMPT TUNE)/CT-181 board so that video waveform becomes flat. Re-perform "4-6-2. RX PROMPT Demod. Adjustment" after performing RX PROMPT VIDEO RF AGC Adjustment". A flat Note : After the adjustment is completed, set the switches as follows. - . S1 (AUX/PROMRT)/YD-25 board (CA-TX7/TX7P) → "PROMPT" - . S6 (AUX/PROMRT)/YD-25 board (CA-TX7/TX7P) → "PROMPT" - . Connect CN7 and CN3 on the CT-181board. (CCU-TX7/ TX7P) - . S2002 (TX ↔ RX) switch/CT-181 board (CCU-TX7/TX7P) → "TX" CCU-TX7 (E)/V1 4-25 Downloaded from www.Manualslib.com manuals search engine # 4-6-3. RX PROMPT VIDEO RF AGC Adjustment Note : When performing this adjustment, the TRIAX cable 50 m to 150 m should be used. Adjustment of CA-TX7 /TX7P must be completed. Equipment : Oscilloscope, Video signal generator (10 STEP signal) To be extended : CT-181 board Preparation : - . S1 (AUX/PROMPT)/YD-25 board (CA-TX7/TX7P) → "AUX" - . S6 (AUX/PROMPT)/YD-25 board (CA-TX7/TX7P) → "AUX" . Connect CN8 and CN3 on the CT-181 board. (CCU-TX7/ TX7P) . S2002 (TX ↔ RX)/CT-181 board (CCU-TX7/TX7P) → "RX" - . S1 (MODE AUTO/MAN)/YD-26 board (CCU-TX7/TX7P) → "AUTO" - . Input the 10 STEP (sub-carrier : ON) signal of the video signal generator to PROMPTER connector on the CA-TX7/ TX7P rear panel. Test point : PROMPTER VIDEO IN connector (CCU-TX7/TX7P rear panel) Note :To measure the video level, make 75 Z termination on the waveform monitor side. Adjusting point :1RV22 (RF AGC DLY)/CT-181 board Adjustment Procedure : . Turn 1RV22 (RF AGC DLY)/CT-181 board fully in the clockwise direction, and then turn it slowly in the counterclockwise direction so that the V SYNC position of waveform becomes flat. (Take care not to over-turn.) Note : After this adjustment is completed, set the switches as follows. - . S1 (AUX/PROMPT)/YD-25 board (CA-TX7/TX7P) → "PROMPT" - . S6 (AUX/PROMPT)/YD-25 board (CA-TX7/TX7P) → "PROMPT" - . Connect CN7 and CN3 on the CT-181 board. (CCU-TX7/ TX7P) - . S2002 (TX ↔ RX)/CT-181 board (CCU-TX7/TX7P) → "TX" 1. -26 Downloaded from www.Manualslib.com manuals search engine CT-181 Board (A SIDE) CCU-TX7 (E)/V1 # 4-6-4. RX PROMPT VIDEO Level Adjustment Note : When performing this adjustment, the TRIAX less than 300 m should be used. Adjustment of CA-TX7/TX7P must be completed. Equipment : Oscilloscope, Video signal generator (10 STEP signal) To be extended : CT-181 board Preparation : - . S1 (AUX/PROMPT)/YD-25 board (CA-TX7/TX7P) → "AUX" - . S6 (AUX/PROMPT)/YD-25 board (CA-TX7/TX7P) → "AUX" - . Connect CN8 and CN3 on the CT-181 board. (CCU-TX7/ TX7P) - . S2002 (TX ↔ RX)/CT-181 board (CCU-TX7/TX7P) → "RX" - . S1 (MODE AUTO/MAN)/YD-26 board (CCU TX7/TX7P) → "AUTO" . Input the 10 STEP signal (sub-carrier : ON) of the video signal generator to PROMPTER OUT connector on the CA-TX7/TX7P real panel. Test point : PROMPTER VIDEO IN connector (CCU-TX7/TX7P rear panel) Note : To measure the video level, make 75 Z termination on the waveform monitor side. Adjusting point : 1RV23 (PROMPT LEVEL)/CT-181 board. A = 140 ±6 IRE [For NTSC] A = 1.00 ±0.05 V [For PAL] ## 4-7. TRIAX Interface System Adjustment ## 4-7-1. Frequency Set Adjustment Note : Check to see that no signal is input to the INCOM connector and PGM connector on the CCU-TX7/ TX7P rear panel or the CCU-TX7/TX7P front panel. Perform the adjustment only when replacing the following part on AA-90 board. LV1, 21, 41, 81, D2, 22, 42, 62 Equipment : Frequency counter, Digital voltmeter To be extended : AA-90 board Adjustment Procedures : 1. Remove the ES-20 and CT-181 boards. 2. Turn on the power switch "ON". 3. AA-90 board (GND : E1) ||Test point|Adj. point|Specifications| |---|---|---|---| |PGM|TP5|1LV81|4.300 ±0.005 MHz| |INCOM|TP3|1LV41|3.600 ±0.005 MHz| |H CONT|TP1|1LV1|3.000 ±0.005 MHz| |CCU DATA|TP2|1LV21|2.500 ±0.005 MHz| Setting after Adjustment : Install the ES-20 and CT-181 boards back into position. A Note : After this adjustment is completed, set the switches as follows. - . S1 (AUX/PROMPT)/YD-25 board (CA-TX7/TX7P) → "PROMPT" - . S6 (AUX/PROMPT)/YD-25 board (CA-TX7/TX7P) → "PROMPT" |. Connect CN7 and CN3 on the CT-181 board. (CCU-TX7/|| |---|---| ||| |. S2002 (TX ↔ RX) /CT-181 board (CCU-TX-7/TX7P)|| - → "TX" CT-181 Board (A SIDE) CCU-TX7 (E)/V1 4-27 Downloaded from www.Manualslib.com manuals search engine # 4-7-2. INCOM Deviation Adjustment Equipment : Spectrum analyzer, Oscilloscope, Audio generator To be extended : AA-90 board Preparations : 1. INTERCOM CH1/CH2 switch (CA-TX7/TX7P side panel) → "CH-1" 2. INTERCOM LINE (CH1/PR1V/CH2) (CCU-TX7/TX7P) front panel → "CH-1 or CH-2" 3. S2002 (2W/RTS/4W)/AA-90 board (CCU-TX7/TX7P) → "4W" 4. Input the 400 Hz sine wave signal of the audio generator to pin 84 (X), pin 83 (Y) and pin 82 (GND)/extension board (AA-90 board). . Fig-2 (Refer to 4-1-5. Audio connection.) 5. Adjust the output level of audio generator so that the level at TP43 (GND : E10)/AA-90 board is 220 mVp-p. Test point : TP3 (GND : E1)/AA-90 board Adjustment point :1RV41 (INCOM DEV)/ AA-90 board Specifications :A = B = 6.0 ±0.2 kHz A B ## 4-7-3. PGM Deviation Adjustment Equipment : Spectrum analyzer, Oscilloscope, Audio generator To be extended : AA-90 board Preparetions : 1. S2081 (0 dB/_20 dB)/AA-90 board (CCU-7X7/TX7P) → "0 dB" 2. Input the 350 Hz sine wave signal of the audio generator to pin 94 (X), pin 93 (Y) and pin 92 (GND)/extension board (AA-90 board). . Fig-2 (Refer to 4-1-5. Audio connection.) 3. Adjust the output level of audio generator so that the level at TP44 (GND : E12)/AA-90 board is 220 mV p-p. Test point : TP5 (GND : E1)/AA-90 board Adjustment point :1RV81 (PGM DEV)/AA-90 board Specifications :A = B = 7.0 ±0.4 kHz |A|B| |---|---| || |---| |Wave form image| CENT FREQ : 3.6 MHz FREQ SPAN : 20 MHz E12 AA-90 PGM IN 0dB -20dB MIC 1 LEVEL 0dB -20dB MIC 2 LEVEL 0dB -20dB MIC TEST CH-1 CH-2 OFF LEVEL IND TP9 TP12 TP44 T401 E10 TP15 LV101 5.6M TUNE TP43 TONE TUNE TP7 LV21 1. CCU DATA LV61 LV41 4.3M 3.6M E11 E1 TP46 LV1 3.0M H CONT INTER COM 2W (CLEAR ) RTS COM 4W RTS CLEAR COM TP3005 TP3002 E3001 TP3004 RV2000 SIDE TONE TP3003 T201 T301 4-28 Downloaded from www.Manualslib.com manuals search engine Wave form image CENT FREQ : 4.3 MHz FREQ SPAN : 20 MHz AA-90 Board (A SIDE) CCU-TX7 (E)/V1 # 4-7-4. INCOM Demodulation Adjustment Note : Perform this adjustment only when replacing 1T401/ AA-90 board. Equipment : Oscilloscope, Audio generator To be extended : AA-90 board AFM-15 board (CA-TX7/TX7P) Preparetions : 1. Input the 1 kHz sine wave signal of the audio generator to pin 2 (GND : pin 1) of INTERCOM/PROGRAM connector (5 pin) on the CA-TX7/TX7P. . Fig-1 (Refer to 4-1-5. Audio connection.) 2. Adjust the output level control of audio generator so that the pin 24 (GND : pin 12) /AFM-15 board is 220 mV p-p. Test point : TP14 (GND : E2)/AA-90 board Adjustment Procedures : 1. Set the input range of oscilloscope to DC made. Adjust the white core of 1T401/AA-90 board slowly so that the DC level at TP14 (GND : E2)/AA-90 board is 1.24 ±0.01 V dc. ## 4-7-5. INCOM Level Adjustment Equipment To be extended : Oscilloscope, Audio generator : AA-90 board FM-15 board (CA-TX7/TX7P) Preparetion : 1. Input the 1 kHz sine wave signal of the audio generator to pin 2 (GND : pin 1) of INTERCOM/PROGRAM connector (5 pin) on the CA-TX7/TX7P. . Fig-1 (Refer to 4-1-5. Audio connection.) 2. Adjust the output level control of audio generator so that the pin 24 (GND : pin 12) /AFM-15 board is 220 mV p-p. Test point : TP15 (GND : E2)/AA-90 board Adjustment point :1RV401 (INCOM LEVEL)/ AA-90 board Specifications :A = 220 ±10 mV p-p ||A| |---|---| 1. ± 0.01 V dc GND 2. Set the input range of oscilloscope to AC mode, and adjust the blue core of 1T401/AA-90 board so that the sine wave is minimum. Minimum 1. Repeat procedure 1. AA-90 Board (A SIDE) CCU-TX7 (E)/V1 4-29 Downloaded from www.Manualslib.com manuals search engine # 4-7-6. MIC 1 Demodulation Adjustment Note : Perform this adjustment only when replacing 1T201/ AA-90 board. Equipment : Oscilloscope, Audio generator To be extended : AA-90 board Preparations : 1. AUDIO SELECT switch (CAMERA/CA-MIC/CA-LINE)/ CA-TX7/TX7P rear panel → "CA-LINE" 2. Input the 1 kHz sine wave signal of the audio generator to CH 1 of MIC IN (rear panel) on the CA-TX7/TX7P. . Fig-2 (Refer to 4-1-5. Audio connection.) 3. Adjust the output level control of audio generator so that the pin 19 (GND : pin 12)/AFM-15 board is 220 mV p-p. Test point : TP8 (GND : E2)/AA-90 board Adjustment Procedures : 1. Adjust the white core of 1T201/AA-90 board slowly so that the DC level at TP8 (GND : E2) /AA-90 board is 1.24 ±0.01 V dc. || |---| |Set the input range of| |the blue core of| |is minimum.| |Repeat procedure 1.| || |www.Manualslib.com| ## 4-7-7. MIC 1 Level Adjustment Equipment To be extended : Oscilloscope, Audio generator : AA-90 board AFM-15 board (CA-TX7/TX7P) Preparations : 1. AUDIO SELECT switch (CAMERA/CA-MIC/CA-LINE)/ CA-TX7/TX7P rear panel → "CA-LINE" 2. Input the 1 kHz sine wave signal of the audio generator to CH 1 of MIC IN (rear panel) on the CA-TX7/TX7P. . Fig-2 (Refer to 4-1-5. Audio connection.) 3. Adjust the output level control of audio generator so that the pin 19 (GND : pin 12) / AFM-15 board is 220 mV p-p. 4. S201 (0 dB/_20 dB)/AA-90 board → 0 dB Test point : TP10 (GND : E2)/AA-90 board Adjustment point :1RV201 (MIC 1 LEVEL)/ AA-90 board 1100 ± 50 mV p-p 1. ± 0.01 V dc GND 2. oscilloscope to AC mode, and adjust 1T201/AA-90 board so that the sine wave Minimum 1. 2. -30 Downloaded from manuals search engine CCU-TX7 (E)/V1 # 4-7-8. MIC 2 Demodulation Adjustment Note : Perform this adjustment only when replacing 1T301/ AA-90 board. Equipment : Oscilloscope, Audio generator To be extended : AA-90 board AFM-15 board (CA-TX7/TX7P) Preparations : 1. AUDIO SELECT switch (CAMERA/CA-MIC/CA-LINE)/ CA-TX7/TX7P → "CA-LINE" 2. Input the 1 kHz sine wave signal of the audio generator to CH 2 of MIC IN (rear panel) on the CA-TX7/TX7P. . Fig-2 (Refer to 4-1-5. Audio connection.) 3. Adjust the output level control of audio generator so that the pin 17 (GND : pin 12)/AFM-15 board is 220 mV p-p. Test point : TP11 (GND : E2)/AA-90 board Adjustment Procedures : 1. Adjust the white core of 1T301/AA-90 board slowly so that the DC level at TP11 (GND : E2) /AA-90 board is 1.24 ±0.01 V dc. || |---| || ## 4-7-9. MIC 2 Level Adjustment Equipment To be extended : Oscilloscope, Audio generator : AA-90 board AFM-15 board (CA-TX7/TX7P) Preparations : 1. AUDIO SELECT switch (CAMERA/CA-MIC/CA-LINE)/ CA-TX7/TX-7P → "CA-LINE" 2. Input the 1 kHz sine wave signal of audio generator to CH 2 of MIC IN (rear panel) on the CA-TX7/TX7P. . Fig-2 (Refer to 4-1-5. Audio connection.) 3. Adjust the output level control of audio generator so that the pin 17 (GND : pin 12)/AFM-15 board is 220 mV p-p. 4. S301 (0 dB/_20 dB)/AA-90 board → "0 dB" Test point : TP13 (GND : E2)/AA-90 board Adjustment point :1RV301 (MIC 2 LEVEL)/ AA-90 board Specifications :A = 1100 ±50 mV p-p A 1. ± 0.01 V dc GND 2. Set the input range of oscilloscope to AC mode, and adjust the blue core of 1T301/AA-90 board so that the sine wave is minimum. Minimum 1. Repeat procedure 1. AA-90 Board (A SIDE) CCU-TX7 (E)/V1 4-31 Downloaded from www.Manualslib.com manuals search engine # 4-7-10. CAM DATA Demodulation Adjustment ## 4-7-11. CAM TONE Adjustment Notes : - . This adjustment for the following cameras must be completed before this adjustment. [For NTSC] DXC-637 or DXC-D30 [For PAL] DXC-637P or DXC-30P - . Perform the adjustment only when replacing 1LV101 (5.6 MHz TUNE)/AA-90 board. Notes : . This adjustment for the following cameras must be completed before this adjustment. [For NTSC] DXC-637 or DXC-D30 [For PAL] DXC-637P or DXC-30P Equipment : Oscilloscope (DC mode) To be extended : AA-90 board Test point : TP7 (GND : E2)/AA-90 board Adjustment point :1RV101 (TONE TUNE)/ AA-90 board Equipment : Oscilloscope 20 MHz BW Limit : ON INPUT made : DC To be extended : AA-90 board Test point TP6 (GND : E2)/AA-90 board Adjustment point :1LV101 (5.6 MHz TUNE)/ AA-90 board Specifications :_100 ±40 mV dc || |---| || ## ( ) Adjustment Procedures : 1. 1RV101 (TONE TUNE)/AA-90 board → "Mechanical center" 2. Turn 1RV101 (TONE TUNE)/AA-90 board slowly clockwise and stop it at the point where the sine wave signal just appears. Measure the DC voltage "a"⋅⋅⋅Fig-1 GND A (fig. 1) Equal (a) Turn slowly clockwise Mechanical center 3. Turn 1RV101 (TONE TUNE)/AA-90 board slowly counterclockwise and stop it at the point where the sine wave signal just appears. Measure the DC voltage "b"⋅⋅⋅Fig-2 |Equal (a)| |---| |Turn slowly counterclockwise| |Equal (b)| |(fig. 2)| |4. Adjust the DC level with 1RV101 (TONE TUNE)/AA-| |90 board so that "a" is equal to "b"⋅⋅⋅Fig-3| |Equal (a)| |A| |RV101 (A = B)| |B| |Equal (b)| |(fig. 3)| 4-32 Downloaded from www.Manualslib.com manuals search engine CCU-TX7 (E)/V1 # SAFETY CHECK-OUT After correcting the original service problem, perform the following safety checks before releasing the set to the customer : Check the metal trim, "metallized" knobs, screws, and all other exposed metal parts for AC leakage. Check leakage as described below. ## LEAKAGE TEST The AC leakage from any exposed metal part to earth ground and from all exposed metal parts to any exposed metal part having a return to chassis, must not exceed 0.5 mA. Leakage current can be measured by any one of three methods. 1. A commercial leakage tester, such as the Simpson 229 or RCA WT-540A. Follow the manufacturers' instructions to use these instruments. 2. A battery-operated AC milliammeter. The Data Precision 245 digital multimeter is suitable for this job. 3. Measuring the voltage drop across a resistor by means of a VOM or battery-operated AC voltmeter. The "limit" indication is 0.75 V, so analog meters must have an accurate low- voltage scale. The Simpson 250 and Sanwa SH-63Trd are examples of a passive VOM that is suitable. Nearly all battery operated digital multimeters that have a 2 V AC range are suitable. (See Fig. A) To Exposed Metal Parts on Set 0.15 µF 1.5 kΩ AC voltmeter (0.75V) Earth Ground Fig A. Using an AC voltmeter to check AC leakage. CCU-TX7 (E)/V1 Downloaded from www.Manualslib.com manuals search engine DXBK-701 (UC, CE) COU-TX7 (UC, CE) CCU-TX7 (UC) CCU-TX7P (CE) E 9-977-286-13 Downloaded from www.Manualslib.com manuals search engine # Sony Corporation # B&P Company Printed in Japan 2003. 9 11 ©1997 ||ManualsLib Projects| |---|---| ||www.manualslib.com| ||www.manualslib.de| ||www.manualslib.es| ||www.manualslib.fr| ||www.manualslib.nl| ||www.manualslib.mx| ||www.manualslib.tech 30+ Languages|