Direct response sweep: 32 frames x 1 cycles (32 total) on COM5 at 38400 8N1
BASELINE heartbeat-compatible RX: 24 bytes, offset 0, 4 frames + 0 bytes
01:38:56.115  TX cycle=1 p1=0x00 p2=0x00 cmd=0x40 state=0x20 value=0xD0 frame 006  00 00 40 20 D0 EA
01:38:56.941  TX cycle=1 p1=0x00 p2=0x00 cmd=0x41 state=0x20 value=0xD0 frame 006  00 00 41 20 D0 EB
01:38:56.941  ANOMALY 24 RX bytes; first mismatch at byte 0: got 07, heartbeat offset 3 expected 00
01:38:56.941  RX raw 07 80 50 24 DD 74 07 80 50 24 DD 74 07 80 50 24 DD 74 07 80 50 24 DD 74
01:38:57.763  TX cycle=1 p1=0x00 p2=0x00 cmd=0x42 state=0x20 value=0xD0 frame 006  00 00 42 20 D0 E8
01:38:57.763  ANOMALY 24 RX bytes; first mismatch at byte 0: got 07, heartbeat offset 3 expected 00
01:38:57.763  RX raw 07 80 50 24 DD 74 07 80 50 24 DD 74 07 80 50 24 DD 74 07 80 50 24 DD 74
01:38:58.588  TX cycle=1 p1=0x00 p2=0x00 cmd=0x43 state=0x20 value=0xD0 frame 006  00 00 43 20 D0 E9
01:38:58.588  ANOMALY 6 RX bytes; first mismatch at byte 0: got 07, heartbeat offset 3 expected 00
01:38:58.588  RX raw 07 80 50 24 DD 74
01:38:59.411  TX cycle=1 p1=0x00 p2=0x00 cmd=0x44 state=0x20 value=0xD0 frame 006  00 00 44 20 D0 EE
Stopped.